In Vivo Dosimetry in the Urethra During Prostate Carbon Ion Radiotherapy

被引:0
|
作者
Matsumoto, S. [1 ,4 ]
Matsufuji, N. [1 ]
Koba, Y. [2 ]
Tsuji, H. [3 ]
机构
[1] Natl Inst Quantum Sci & Technol, Inst Quantum Med Sci, Dept Accelerator & Med Phys, Quantum Med Sci Directorate, Chiba, Japan
[2] Natl Inst Quantum Sci & Technol, Natl Inst Radiol Sci, Dept Radiat Regulatory Sci Res, Quantum Med Sci Directorate, Chiba, Japan
[3] Natl Inst Quantum Sci & Technol, Inst Quantum Med Sci, QST Hosp, Chiba, Japan
[4] Natl Inst Quantum Sci & Technol, 4 9 1 Anagawa,Inage ku, Chiba 2638555, Japan
关键词
Radiation dosimeters; prostate cancer; urinary catheters; in vivo dosimetry; SYSTEM;
D O I
10.21873/anticanres.16389
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Aim: In vivo dosimetry can prevent dose delivery errors by directly measuring the dose of radiation administered to a patient. However, a method for in vivo dosimetry during carbon ion radiotherapy (CIRT) has not been established. Therefore, we investigated data from in vivo dosimetry of the urethra during CIRT for prostate cancer using small spherical diode dosimeters (SSDDs). Patients and Methods: This study included five patients enrolled in a clinical trial (jRCT identifier: jRCTs032190180) on which the use of four-fraction CIRT for prostate cancer was examined. The urethral dose during CIRT for prostate cancer was measured using the SSDDs inserted into the ureteral catheter. The relative error between the in vivo and calculated doses obtained using the Xio-N treatment planning system was determined. Additionally, a dose-response stability test for the in vivo dosimeter was performed under clinical conditions. Results: The relative error between the in vivo and calculated urethral doses ranged from 6 to 12%. The dose-response stability under clinical conditions of the measured dose was <= 1%. Therefore, an error >1% would be due to an interfractional patient setup error in the large dose gradient in the urethra. Conclusion: The usefulness of in vivo dosimetry using SSDDs in CIRT and SSDDs' potential for detecting dose delivery errors during CIRT is herein highlighted.
引用
收藏
页码:2259 / 2264
页数:6
相关论文
共 50 条
  • [41] In vivo dosimetry for lung radiotherapy including SBRT
    McCurdy, Boyd M. C.
    McCowan, Peter M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 123 - 130
  • [42] IN VIVO DOSIMETRY WITH DIODES IN A RADIOTHERAPY DEPARTMENT IN PAKISTAN
    Tunio, Mutahir
    Rafi, Mansoor
    Ali, Shoukat
    Ahmed, Zaeem
    Zameer, Asad
    Hashmi, Altaf
    Maqbool, Syed A.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (04) : 608 - 613
  • [43] The implementation of in vivo dosimetry in a small radiotherapy department
    Voordeckers, M
    Goossens, H
    Rutten, J
    Van den Bogaert, W
    RADIOTHERAPY AND ONCOLOGY, 1998, 47 (01) : 45 - 48
  • [44] A survey of current in vivo radiotherapy dosimetry practice
    Edwards, CR
    Grieveson, MH
    Mountford, PJ
    Rolfe, P
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 299 - 302
  • [45] Kinetics of Prostate-Specific Antigen after Carbon Ion Radiotherapy for Prostate Cancer
    Darwis, Narisa Dewi Maulany
    Oike, Takahiro
    Kawamura, Hidemasa
    Kawahara, Masahiro
    Kubo, Nobuteru
    Sato, Hiro
    Miyasaka, Yuhei
    Katoh, Hiroyuki
    Ishikawa, Hitoshi
    Matsui, Hiroshi
    Miyazawa, Yoshiyuki
    Ito, Kazuto
    Suzuki, Kazuhiro
    Gondhowiardjo, Soehartati
    Nakano, Takashi
    Ohno, Tatsuya
    CANCERS, 2020, 12 (03)
  • [46] IN VIVO DOSIMETRY WITH MOSFETS DURING INTRA-OPERATIVE RADIOTHERAPY FOR PARTIAL BREAST IRRADIATION
    Petoukhova, A.
    van Wingerden, K.
    Koper, P.
    Ceha, H.
    Verbeek-de Kanter, A.
    Marinelli, A.
    van der Sijp, J.
    Struikmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S11 - S11
  • [47] Pre-treatment and in vivo fetal dosimetry in brain radiotherapy treatment during pregnancy
    Valenti, M.
    Parisotto, M.
    Ardito, C.
    Puschi, M.
    Costantini, S.
    Cardinali, M.
    Maggi, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S752 - S753
  • [48] In vivo dosimetry using radiochromic films (EBT-2) during intraoperative radiotherapy
    Yekta, Zahra Rahimzade
    Mahdavi, Seied Rabi Mehdi
    Baghani, Hamid Reza
    Robatjazi, Mostafa
    Mostaar, Ahmad
    Mirzaie, Hamidreza
    Sardari, Dariush
    Akbari, Mohammad Esmaeil
    Nafisi, Nahid
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2016, 15 (04) : 378 - 384
  • [49] Evaluation of a microMOSFET radiation sensor for the monitoring of in vivo dosimetry during total scalp radiotherapy
    Dong, SL
    Yen, SH
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1761 - 1765
  • [50] Current outcomes of clinical trials in carbon ion radiotherapy for prostate cancer
    Tsuji, H.
    Kato, H.
    Nomiya, T.
    Kamada, T.
    Mizoe, J.
    Shimazaki, J.
    Tsujii, H.
    EJC SUPPLEMENTS, 2007, 5 (04): : 288 - 288