In Vivo Dosimetry in the Urethra During Prostate Carbon Ion Radiotherapy

被引:0
|
作者
Matsumoto, S. [1 ,4 ]
Matsufuji, N. [1 ]
Koba, Y. [2 ]
Tsuji, H. [3 ]
机构
[1] Natl Inst Quantum Sci & Technol, Inst Quantum Med Sci, Dept Accelerator & Med Phys, Quantum Med Sci Directorate, Chiba, Japan
[2] Natl Inst Quantum Sci & Technol, Natl Inst Radiol Sci, Dept Radiat Regulatory Sci Res, Quantum Med Sci Directorate, Chiba, Japan
[3] Natl Inst Quantum Sci & Technol, Inst Quantum Med Sci, QST Hosp, Chiba, Japan
[4] Natl Inst Quantum Sci & Technol, 4 9 1 Anagawa,Inage ku, Chiba 2638555, Japan
关键词
Radiation dosimeters; prostate cancer; urinary catheters; in vivo dosimetry; SYSTEM;
D O I
10.21873/anticanres.16389
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Aim: In vivo dosimetry can prevent dose delivery errors by directly measuring the dose of radiation administered to a patient. However, a method for in vivo dosimetry during carbon ion radiotherapy (CIRT) has not been established. Therefore, we investigated data from in vivo dosimetry of the urethra during CIRT for prostate cancer using small spherical diode dosimeters (SSDDs). Patients and Methods: This study included five patients enrolled in a clinical trial (jRCT identifier: jRCTs032190180) on which the use of four-fraction CIRT for prostate cancer was examined. The urethral dose during CIRT for prostate cancer was measured using the SSDDs inserted into the ureteral catheter. The relative error between the in vivo and calculated doses obtained using the Xio-N treatment planning system was determined. Additionally, a dose-response stability test for the in vivo dosimeter was performed under clinical conditions. Results: The relative error between the in vivo and calculated urethral doses ranged from 6 to 12%. The dose-response stability under clinical conditions of the measured dose was <= 1%. Therefore, an error >1% would be due to an interfractional patient setup error in the large dose gradient in the urethra. Conclusion: The usefulness of in vivo dosimetry using SSDDs in CIRT and SSDDs' potential for detecting dose delivery errors during CIRT is herein highlighted.
引用
收藏
页码:2259 / 2264
页数:6
相关论文
共 50 条
  • [31] Two-dimensional in vivo rectal dosimetry using an endorectal balloon with unfoldable radiochromic film during prostate cancer radiotherapy
    Jeang, Eun Hee
    Min, Soonki
    Cho, Kwan Ho
    Hwang, Ui-Jung
    Choi, Sang Hyoun
    Kwak, Jungwon
    Jeong, Jong Hwi
    Kim, Haksoo
    Lee, Se Byeong
    Shin, Dongho
    Park, Jeonghoon
    Kim, Joo-Young
    Kim, Dae Yong
    Lim, Young Kyung
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (02) : 327 - 332
  • [32] Three-dimensional BANG™ gel dosimetry in conformal carbon ion radiotherapy
    Ramm, U
    Weber, U
    Bock, M
    Krämer, M
    Bankamp, A
    Damrau, M
    Thilmann, C
    Bottcher, HD
    Schad, LR
    Kraft, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : N95 - N102
  • [33] In vivo alanin/electron spin resonance (ESR) dosimetry in the urethra during 192lr HDR brachtherapy in patients with prostate carcinoma: a phantom study
    Wagner, D. M.
    Anton, M.
    Selbach, H. J.
    Hackel, T.
    Hermann, R. M.
    Hess, C. F.
    Vorwerk, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 20 - 20
  • [34] Ten years experience of carbon ion radiotherapy for prostate cancer
    Tsuji, H.
    Ishikawa, H.
    Hirasawa, N.
    Yanagi, T.
    Kamada, T.
    Mizoe, J.
    Tsujii, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S327 - S328
  • [35] Biochemical Failure after Carbon Ion Radiotherapy for Prostate Cancer
    Shimazaki, Jun
    Tsuji, Hiroshi
    Ishikawa, Hitoshi
    Kamada, Tadashi
    Harada, Masaoki
    Akakura, Koichiro
    Suzuki, Hiroyoshi
    Ichikawa, Tomohiko
    Tsujiii, Hirohiko
    ANTICANCER RESEARCH, 2012, 32 (08) : 3267 - 3273
  • [36] A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy
    O'Keeffe, S.
    McCarthy, D.
    Woulfe, P.
    Grattan, M. W. D.
    Hounsell, A. R.
    Sporea, D.
    Mihai, L.
    Vata, I.
    Leen, G.
    Lewis, E.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1050):
  • [37] The potential application of silver and positron emission tomography for in vivo dosimetry during radiotherapy
    Hansen, Anders T.
    Hansen, Soren B.
    Petersen, Jorgen B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (02): : 353 - 360
  • [38] In vivo dosimetry in brachytherapy of prostate cancer
    Kawczynska, M.
    Bulski, W.
    Czyzew, B.
    Garmol, D.
    Gruszczynska, E.
    Kasprowicz, A.
    Krol, M.
    Kulik, A.
    Lyczek, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S465 - S465
  • [39] In vivo alanine/electron spin resonance (ESR) dosimetry in radiotherapy of prostate cancer:: A feasibility study
    Wagner, Daniela
    Anton, Mathias
    Vorwerk, Hilke
    Gsaenger, Tammo
    Christiansen, Hans
    Poppe, Bjoern
    Hess, Clemens Friedrich
    Hermann, Robert Michael
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 (01) : 140 - 147
  • [40] Gafchromic film in vivo dosimetry for oral radiotherapy
    Chuang, K.
    Chen, H.
    Lin, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2456 - 2456