In Vivo Dosimetry in the Urethra During Prostate Carbon Ion Radiotherapy

被引:0
|
作者
Matsumoto, S. [1 ,4 ]
Matsufuji, N. [1 ]
Koba, Y. [2 ]
Tsuji, H. [3 ]
机构
[1] Natl Inst Quantum Sci & Technol, Inst Quantum Med Sci, Dept Accelerator & Med Phys, Quantum Med Sci Directorate, Chiba, Japan
[2] Natl Inst Quantum Sci & Technol, Natl Inst Radiol Sci, Dept Radiat Regulatory Sci Res, Quantum Med Sci Directorate, Chiba, Japan
[3] Natl Inst Quantum Sci & Technol, Inst Quantum Med Sci, QST Hosp, Chiba, Japan
[4] Natl Inst Quantum Sci & Technol, 4 9 1 Anagawa,Inage ku, Chiba 2638555, Japan
关键词
Radiation dosimeters; prostate cancer; urinary catheters; in vivo dosimetry; SYSTEM;
D O I
10.21873/anticanres.16389
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Aim: In vivo dosimetry can prevent dose delivery errors by directly measuring the dose of radiation administered to a patient. However, a method for in vivo dosimetry during carbon ion radiotherapy (CIRT) has not been established. Therefore, we investigated data from in vivo dosimetry of the urethra during CIRT for prostate cancer using small spherical diode dosimeters (SSDDs). Patients and Methods: This study included five patients enrolled in a clinical trial (jRCT identifier: jRCTs032190180) on which the use of four-fraction CIRT for prostate cancer was examined. The urethral dose during CIRT for prostate cancer was measured using the SSDDs inserted into the ureteral catheter. The relative error between the in vivo and calculated doses obtained using the Xio-N treatment planning system was determined. Additionally, a dose-response stability test for the in vivo dosimeter was performed under clinical conditions. Results: The relative error between the in vivo and calculated urethral doses ranged from 6 to 12%. The dose-response stability under clinical conditions of the measured dose was <= 1%. Therefore, an error >1% would be due to an interfractional patient setup error in the large dose gradient in the urethra. Conclusion: The usefulness of in vivo dosimetry using SSDDs in CIRT and SSDDs' potential for detecting dose delivery errors during CIRT is herein highlighted.
引用
收藏
页码:2259 / 2264
页数:6
相关论文
共 50 条
  • [1] IN-VIVO DOSIMETRY IN THE URETHRA AFTER INTERSTITIAL PROSTATE IRRADIATION.
    Bloemen-van Gurp, E.
    Haanstra, B.
    Murrer, L.
    van Gils, F.
    Pijls, R.
    Dekker, A.
    Mijnheer, B.
    Lambin, P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S163 - S163
  • [2] In vivo dosimetry during prostate irradiation
    Orlandi, G
    Ferri, A
    Natali, M
    Barbieri, E
    Benati, M
    Frezza, G
    Gaiba, W
    Lombardo, E
    Parmeggiani, C
    Pini, S
    Ruggeri, R
    Vanini, R
    Bergamini, C
    PHYSICA MEDICA, 1997, 13 : 136 - 138
  • [3] In Vivo Dosimetry with MOSFET Detector during Radiotherapy
    Cho, Sam Ju
    Kim, Won Taek
    Ki, Yong Gan
    Kwon, Soo Il
    Lee, Sang Hoon
    Do Huh, Hyun
    Cho, Kwang Hwan
    Kwon, Byung Hyun
    Kim, Dong Won
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1987 - +
  • [4] In vivo dosimetry during external photon beam radiotherapy
    Essers, M
    Mijnheer, BJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (02): : 245 - 259
  • [5] Optical fibre sensors: their role in in vivo dosimetry for prostate cancer radiotherapy
    Woulfe P.
    Sullivan F.J.
    O’Keeffe S.
    Cancer Nanotechnology, 2016, 7 (1)
  • [6] In vivo real-time rectal wall dosimetry for prostate radiotherapy
    Hardcastle, Nicholas
    Cutajar, Dean L.
    Metcalfe, Peter E.
    Lerch, Michael L. F.
    Perevertaylo, Vladimir L.
    Tome, Wolfgang A.
    Rosenfeld, Anatoly B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (13): : 3859 - 3871
  • [7] Visualising the urethra for prostate radiotherapy planning
    Richardson, Matthew
    Skehan, Kate
    Wilton, Lee
    Sams, Joshua
    Samuels, Justin
    Goodwin, Jonathan
    Greer, Peter
    Sridharan, Swetha
    Martin, Jarad
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2021, 68 (03) : 282 - 288
  • [8] Carbon-ion radiotherapy: clinical aspects and related dosimetry
    Fukumura, A.
    Tsujii, H.
    Kamada, T.
    Baba, M.
    Tsuji, H.
    Kato, H.
    Kato, S.
    Yamada, S.
    Yasuda, S.
    Yanagi, T.
    Kato, H.
    Hara, R.
    Yamamoto, N.
    Mizoe, J.
    Akahane, K.
    Fukuda, S.
    Furusawa, Y.
    Iwata, Y.
    Kanai, T.
    Kanematsu, N.
    Kitagawa, A.
    Matsufuji, N.
    Minohara, S.
    Miyahara, N.
    Mizuno, H.
    Murakami, T.
    Nishizawa, K.
    Noda, K.
    Takada, E.
    Yonai, S.
    RADIATION PROTECTION DOSIMETRY, 2009, 137 (1-2) : 149 - 155
  • [9] APPLICATION OF MOSFET DOSIMETRY FOR IN VIVO DOSIMETRY IN RADIOTHERAPY
    Bloemen-van Gurp, E.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S49 - S50
  • [10] Characteristics of in vivo radiotherapy dosimetry
    Edwards, C. R.
    Mountford, P. J.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (983): : 881 - 883