Comparison of the accuracy between full-arch digital scans and scannable impression materials: an in vitro study

被引:3
|
作者
Grande, Francesco [1 ,2 ,3 ]
Celeghin, Giordano [1 ]
Gallinaro, Federica [1 ]
Mobilio, Nicola [1 ]
Catapano, Santo [1 ]
机构
[1] Univ Ferrara, Dept Prosthodont, Ferrara, Italy
[2] Polytech Univ Turin, Dept Mech & Aerosp Engn, Turin, Italy
[3] Univ Ferrara, Dept Prosthodont, Via Luigi Borsari 46, I-44121 Ferrara, Italy
关键词
Dental impression materials; Dental arch; Dimensional measurement accuracy; CONVENTIONAL IMPRESSIONS; DENTAL IMPRESSIONS; MARGINAL FIT; RESTORATIONS; PRECISION; DIGITIZATION; TRUENESS; PATIENT;
D O I
10.23736/S2724-6329.23.04766-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BACKGROUND: In some clinical cases, full-arch impression could be difficult to take correctly with the digital way. Patients with high flow salivary rate or with difficulties in mouth opening can still benefit from a conventional impression with elastomer materials that can be directly or indirectly digitized. The aim of this study was to compare the accuracy and precision of two different intraoral scanners (IOSs) and an impression material with scannable properties, by means of three-dimensional analysis of a complete dental arch. METHODS: An anatomical model of complete upper arch, modified with a Scan body placed in the retroincisive area, was used. It was firstly scanned by a desktop scanner to create a digital reference model. Then, 3 groups were created, each constituted by 5 samples. In the first group, 5 impressions were taken from the same master model with the scan-nable PVS material (Hydrorise Implant), 5 scans were taken using Trios4 (3Shape) and other 5 scans with iTero Element 5D (iTero). STL files obtained from IOSs, and scanned impressions were three-dimensionally superimposed on the STL file of the reference model using the Scan body geometry. RESULTS: The ANOVA Test (P<0.005) did not show any statistically significant difference between the accuracy and precision values of the groups. Each group shows clinically acceptable deviations from the reference model. CONCLUSIONS: Scannable polyvinylsiloxane impression materials are equally accurate and precise as the two IOSs tested in full-arch dentate impressions.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [1] Accuracy of Conventional and Digital Methods of Obtaining Full-Arch Dental Impression (In Vitro Study)
    Husein, Hassan A.
    Morad, Mhd. Luai
    Kanout, Shaza
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [2] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Keul, Christine
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (02) : 735 - 745
  • [3] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Christine Keul
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 735 - 745
  • [4] Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation
    Pesce, Paolo
    Pera, Francesco
    Setti, Paolo
    Menini, Maria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 171 - 175
  • [5] Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry
    Cheng, Jing
    Zhang, Haidong
    Liu, Hailin
    Li, Junying
    Wang, Hom-Lay
    Tao, Xian
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 560 - 572
  • [6] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)
  • [7] Full-Arch Digital Implant Impression Trueness: An in Vivo Study
    Rutkunas, Vygandas
    Kules, Daniel
    Revilla-Leon, Marta
    Akulauskas, Mykolas
    Auskalnis, Liudas
    Gendviliene, Ieva
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [8] Comparison of Intraoral Scanning Modes in Three Distinct Full-Arch Digital Implant Impression Scenarios: An In Vitro Study
    Sezer, Taygun
    Yilmaz, Erkan
    Esim, Emir
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : e217 - e222
  • [9] In vitro and in vivo accuracy of full-arch digital implant impressions
    Rutkunas, Vygandas
    Gedrimiene, Agne
    Akulauskas, Mykolas
    Fehmer, Vincent
    Sailer, Irena
    Jegelevicius, Darius
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (12) : 1444 - 1454
  • [10] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694