Hepatic fat quantification in dual-layer computed tomography using a three-material decomposition algorithm

被引:5
|
作者
Demondion, Emilie [1 ]
Ernst, Olivier [1 ]
Louvet, Alexandre [2 ]
Robert, Benjamin [3 ]
Kafri, Galit [4 ]
Langzam, Eran [4 ]
Vermersch, Mathilde [1 ,5 ]
机构
[1] Lille Univ Hosp, Med Imaging Dept, 2 Ave Oscar Lambret, Lille, France
[2] Lille Univ Hosp, Dept Gastroenterol & Hepatol, 2 Ave Oscar Lambret, Lille, France
[3] Philips Healthcare, CT Clin Sci, Paris, France
[4] Philips Healthcare, CT Clin Sci, Haifa, Israel
[5] Valenciennes Hosp Ctr, Med Imaging Dept, 114 Ave Desandrouin, Valenciennes, France
关键词
Fatty liver; Non-alcoholic fatty liver disease; Radiography (dual-energy scanned projection); Tomography (X-ray computed); MULTIMATERIAL DECOMPOSITION; CT; ASSOCIATION; STEATOSIS; FRACTION; MRI;
D O I
10.1007/s00330-023-10382-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe purpose of this study was to evaluate a three-material decomposition algorithm for hepatic fat quantification using a dual-layer computed tomography (DL-CT) and MRI as reference standard on a large patient cohort.MethodA total of 104 patients were retrospectively included in our study, i.e., each patient had an MRI exam and a DL-CT exam in our institution within a maximum of 31 days. Four regions of interest (ROIs) were positioned blindly and similarly in the liver, by two independent readers on DL-CT and MRI images. For DL-CT exams, all imaging phases were included. Fat fraction agreement between CT and MRI was performed using intraclass correlation coefficients (ICC), determination coefficients R2, and Bland-Altman plots. Diagnostic performance was determined using sensitivity, specificity, and positive and negative predictive values. The cutoff for steatosis was 5%.ResultsCorrelation between MRI and CT data was excellent for all perfusion phases with ICC calculated at 0.99 for each phase. Determination coefficients R2 were also good for all perfusion phases (about 0.95 for all phases). Performance of DL-CT in the diagnosis of hepatic steatosis was good with sensitivity between 89 and 91% and specificity ranging from 75 to 80%, depending on the perfusion phase. The positive predictive value was ranging from 78 to 93% and the negative predictive value from 82 to 86%.ConclusionMulti-material decomposition in DL-CT allows quantification of hepatic fat fraction with a good correlation to MRI data.Clinical relevance statementThe use of DL-CT allows for detection of hepatic steatosis. This is especially interesting as an opportunistic finding CT performed for other reasons, as early detection can help prevent or slowdown the development of liver metabolic disease.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.Key Points center dot Hepatic fat fractions provided by the dual-layer CT algorithm is strongly correlated with that measured on MRI.center dot Dual-layer CT is accurate to detect hepatic steatosis >= 5%.center dot Dual-layer CT allows opportunistic detection of steatosis, on CT scan performed for various indications.
引用
收藏
页码:3708 / 3718
页数:11
相关论文
共 50 条
  • [41] Design Optimization of A Triple-Layer Flat-Panel Detector for Three-Material Decomposition
    Jiang, Xiao
    Tivnan, Matthew
    Zhang, Xiaoxuan
    Stayman, J. Webster
    Gang, Grace J.
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [42] Comparison of image and data domain methods for three-material decomposition in dual-energy CT
    Humphries, T.
    McGarity, R.
    Uy, K.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [43] Dual Energy Material Decomposition for Volumetric Breast Density Measurement Using a Direct-Indirect Dual-Layer Detector
    Huang, H.
    Duan, X.
    Zhao, W.
    MEDICAL PHYSICS, 2022, 49 (06) : E415 - E416
  • [44] Impact of scatter radiation on spectral quantification performance of first- and second-generation dual-layer spectral computed tomography
    Salazar, Edgar
    Liu, Leening P.
    Perkins, Amy E.
    Halliburton, Sandra S.
    Shapira, Nadav
    Litt, Harold I.
    Noel, Peter B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [45] Fat Fraction Measurements Using a Three-Material Decomposition Dual-Energy CT Technique Accounting for Bone Minerals: Evaluation in a Bone Marrow Phantom Using MRI as Reference
    Li, Baojun
    Hua, Ning
    Li, Janelle
    Andreu-Arasa, V. Carlota
    LeBedis, Christina
    Anderson, Stephan W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (03) : 553 - 554
  • [46] The application of dual-layer spectral detector computed tomography in solitary pulmonary nodule identification
    Wen, Qingyun
    Yue, Yong
    Shang, Jin
    Lu, Xiaomei
    Gao, Lu
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (02) : 521 - +
  • [47] Performance characterization of a prototype dual-layer cone-beam computed tomography system
    Stahl, Fredrik
    Schafer, Dirk
    Omar, Artur
    van de Haar, Peter
    van Nijnatten, Fred
    Withagen, Paul
    Thran, Axel
    Hummel, Erik
    Menser, Bernd
    Holmberg, Ake
    Soderman, Michael
    Delgado, Anna Falk
    Poludniowski, Gavin
    MEDICAL PHYSICS, 2021, 48 (11) : 6740 - 6754
  • [48] Use of dual-layer spectral detector computed tomography in the diagnosis of pancreatic neuroendocrine neoplasms
    Yuan, Jiaxin
    Wang, Yangdi
    Hu, Xuefang
    Shi, Siya
    Zhang, Ning
    Wang, Liqin
    Deng, Weiwei
    Feng, Shi-Ting
    Peng, Zhenpeng
    Luo, Yanji
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 159
  • [49] Improved detectability of hypoattenuating focal pancreatic lesions by dual-layer computed tomography using virtual monoenergetic images
    Nada El Kayal
    Ahmed Mohallel
    David Maintz
    Mohamed Eid
    Doaa Mokhtar Emara
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [50] Material decomposition with dual- and multi-energy computed tomography
    Rajesh Bhayana
    Anushri Parakh
    Avinash Kambadakone
    MRS Communications, 2020, 10 : 558 - 565