Design Optimization of A Triple-Layer Flat-Panel Detector for Three-Material Decomposition

被引:0
|
作者
Jiang, Xiao [1 ]
Tivnan, Matthew [2 ]
Zhang, Xiaoxuan [3 ]
Stayman, J. Webster [1 ]
Gang, Grace J. [3 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
D O I
10.1117/12.3006385
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Spectral radiography and fluoroscopy with multi-layer flat-panel detectors (FPD) is being actively investigated in a range of clinical applications. For applications involving contrast administration, maximal contrast resolution is achieved when overlaying background anatomy is completely removed. This calls for three-material decomposition (soft tissue, bone, and contrast) enabled by measurements in three energy channels. We have previously demonstrated the feasibility of such decomposition using a triple-layer detector. While algorithmic solutions can be adopted to mitigate noise in the material basis images, in this work, we seek to fundamentally improve the conditioning of the problem through optimized system design. Design parameters include source voltage, the thickness of the top two CsI scintillators, and the thickness of two copper interstitial filters. The design objective is to minimize noise in the basis image containing contrast, chosen as gadolinium in this work to improve separation from bone. The optimized design was compared with other designs with unoptimized scintillator thickness and/or without interstitial filtration. Results show that CsI thickness optimization and interstitial filtration can significantly reduce noise in the gadolinium image by 35.7% and 42.7% respectively within a lung ROI, which in turn boosts detectability of small vessels. Gadolinium and bone signals are separated in all cases. Visualization of coronary vessels is enabled by the combining optimized system design and regularization. Results from this work demonstrate that three-material decomposition can be significantly improved with system design optimization. Optimized designs obtained from this work can inform imaging techniques selection and triple-layer detector fabrication for spectral radiography.
引用
收藏
页数:6
相关论文
共 41 条
  • [1] Evaluation of A Novel Stacked Triple-Layer Flat-Panel X-Ray Detector for Dual-Energy and Digital Radiography Imaging
    Maurino, S. Lopez
    Ghanbarzadeh, S.
    Ghaffari, S.
    Zhang, T.
    Cunningham, I.
    Karim, K. S.
    MEDICAL PHYSICS, 2018, 45 (06) : E137 - E137
  • [2] Dual kVp material decomposition using flat-panel detectors
    Walter, D
    Wu, XY
    Du, YF
    Tkaczyk, EJ
    Ross, WR
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 29 - 39
  • [3] Characterization and potential applications of a dual-layer flat-panel detector
    Shi, Linxi
    Lu, Minghui
    Bennett, N. Robert
    Shapiro, Edward
    Zhang, Jin
    Colbeth, Richard
    Star-Lack, Josh
    Wang, Adam S.
    MEDICAL PHYSICS, 2020, 47 (08) : 3332 - 3343
  • [4] Improvement of three-material decomposition in spectral mammography with a photon-counting detector
    Lee, Minjae
    Kim, Hyemi
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (02) : 91 - 100
  • [5] Improvement of three-material decomposition in spectral mammography with a photon-counting detector
    Minjae Lee
    Hyemi Kim
    Journal of the Korean Physical Society, 2022, 81 : 91 - 100
  • [6] High-resolution model-based material decomposition in dual-layer flat-panel CBCT
    Wang, Wenying
    Ma, Yiqun
    Tivnan, Matthew
    Li, Junyuan
    Gang, Grace J.
    Zbijewski, Wojciech
    Lu, Minghui
    Zhang, Jin
    Star-Lack, Josh
    Colbeth, Richard E.
    Stayman, J. Webster
    MEDICAL PHYSICS, 2021, 48 (10) : 6375 - 6387
  • [7] Indirect flat-panel detector with avalanche gain: Design and operation of the avalanche photoconductor
    Zhao, W
    Li, D
    Reznik, A
    Lui, B
    Hunt, DC
    Tanioka, K
    Rowlands, JA
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 352 - 360
  • [8] Dual-energy head cone-beam CT using a dual-layer flat-panel detector: Hybrid material decomposition and a feasibility study
    Wang, Zhilei
    Zhou, Hao
    Gu, Shan
    Xia, Yingxian
    Liao, Haiyue
    Deng, Yifan
    Gao, Hewei
    MEDICAL PHYSICS, 2023, 50 (11) : 6762 - 6778
  • [9] Model-based CBCT scatter correction with dual-layer flat-panel detector
    Zhang, Xin
    Xie, Jixiong
    Tan, Yuhang
    Su, Ting
    Zhu, Jiongtao
    Cui, Han
    Xia, Dongmei
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    MEDICAL PHYSICS, 2025, 52 (03) : 1500 - 1514
  • [10] Thermal Optimization Design for a Small Flat-Panel Synthetic Aperture Radar Satellite
    Bai, Tian
    Zhang, Yuanbo
    Kong, Lin
    Ao, Hongrui
    Yu, Jisong
    Zhang, Lei
    AEROSPACE, 2024, 11 (12)