Bipolar radiofrequency ablation lesion areas and confluence: An ex vivo study and technical report

被引:2
|
作者
Wondra, Andrew [1 ,2 ]
Gulhar, Shelly [1 ,2 ]
Brestle, Mason D. [3 ,4 ]
Chou, Jiling [5 ]
Desai, Mehul J. [3 ,6 ,7 ]
机构
[1] MedStar Georgetown Univ, Dept Rehabil Med, Washington, DC USA
[2] MedStar Natl Rehabil Hosp, Washington, DC USA
[3] Int Spine Pain & Performance Ctr, Washington, DC USA
[4] Philadelphia Coll Osteopath Med, Suwanee, GA USA
[5] MedStar Hlth Res Inst, Hyattsville, MD USA
[6] George Washington Univ, Sch Med & Hlth Sci, Washington, DC USA
[7] Int Spine Pain & Performance Ctr, 2021 K St NW,Suite 615, Washington, DC 20006 USA
关键词
bipolar; interprobe distance; lesion confluence; lesion midpoint area; radiofrequency ablation; FACET JOINT DENERVATION; LOW-BACK-PAIN; DOUBLE-BLIND; NEUROTOMY; VOLUMES; ENERGY;
D O I
10.1111/papr.13323
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
IntroductionRadiofrequency ablation (RFA) has been used for nearly 100 years, treating an array of medical conditions including chronic pain. Radiofrequency (RF) energy depolarizes and repolarizes tissues adjacent to a probe producing heat and causing direct thermal injury. When positioned adjacent to neural structures, it leads to neural tissue injury and cell death interrupting pain signaling with the ultimate goal of providing lasting pain relief. Today, RFA is commonly used to treat cervical, thoracic, and lumbar zygapophyseal joints, sacroiliac joint, and more recently large peripheral joint-mediated pain. There are several applications of RFA systems, including bipolar, conventional thermal, cooled, protruding, and pulsed. As yet, no study has determined the best technical practice for bipolar RFA.ObjectiveThis ex vivo study examines RFA lesion midpoint (LMP) area and lesion confluence comparing three different commonly used gauge (g) probes (18-g, 20-g, and 22-g) with 10-mm active tips at various interprobe distances (IPD) to guide best technical practices for its clinical application.MethodsBipolar RFA lesions were generated in preservative-free chicken breast specimens using three different gauge probes (18-g, 20-g, and 22-g) with 10-mm active tips at various IPD (6, 8, 10, 12, 14, 16, and 18 mm). RF was applied for 105 s (15-s ramp time) at 80 degrees C for each lesion at both room and human physiological temperature. The specimen tissues were dissected through the lesion to obtain a length, width, and depth, which were used to calculate the LMP area (mm2). The LMP areas of each thermal ablation were investigated using visualization and descriptive analysis. The Kruskal-Wallis test was performed to compare LMP areas between the two temperature groups and the three different gauge probe subgroups at the various IPDs.ResultsOf the 36 RF lesions (14: 18-g, 12: 20-g, and 10: 22-g) performed, 24 demonstrated lesion confluence. The average time to reach 80 degrees C was 16-17 s; therefore, the average time of RF-energy delivery (at goal temperature) was 88-89 s despite varying needle size or IPD. Comparing the 25 and 37 degrees C groups, 18-g probes produced mean LMP areas of 73.7 and 79.2 mm2, respectively; 20-g probes produced mean LMP areas of 66 and 66.8 mm2, respectively; 22-g probes produced mean LMP areas of 56.6 and 59.7 mm2, respectively. There was no statistical evidence to state a difference regarding LMP area between temperature groups; however, the 18-g probes produced consistently larger LMP areas in the 37 degrees C compared to 25 degrees C specimen groups at each IPD. Lesion confluence was lost for 18-g, 20-g, and 22-g probes at IPD of 14, 12, and 10 mm, respectively, in both 25 and 37 degrees C groups. LMP area was similar between 6 and 8 mm IPD in all of the three-gauge groups; however, there was a significant drop in LMP area from 8 mm IPD to 10 mm and greater. The 18-g, 20-g, and 22-g probes all demonstrated a sharp decline in LMP area when increasing the IPD from 8 to 10 mm.ConclusionThis ex vivo technical study evaluated bipolar RFA LMP areas and lesion confluence, and determined the recommended IPD of 18-g, 20-g, and 22-g probes to be less than 12, 10, and 8 mm, respectively, for best clinical practice. Placing bipolar probes at an IPD greater than 14, 12, and 10 mm, respectively, risks the loss of lesion confluence and failure to produce a clinically significant treatment response due to lack of nerve capture. In clinical practice, the use of injectate may produce larger lesions than demonstrated in this study. Additionally, in vivo factors may impact ablation zone size and ablation patterns. As there are a paucity of studies comparing various RFA applications and conventional RFA needles are least expensive, it is possible that bipolar conventional RFA is more cost-effective than other techniques.
引用
收藏
页码:489 / 501
页数:13
相关论文
共 50 条
  • [31] Combined Bipolar and V-Shaped Lesions for Lumbar Facet Radiofrequency Ablation: A Technical Report
    Sagir, Afrin
    Bolash, Robert
    PAIN MEDICINE, 2022, 23 (04) : 862 - 866
  • [32] Laparoscopically guided bipolar radiofrequency ablation of areas of porcine liver
    Curley, SA
    Davidson, BS
    Fleming, RY
    Izzo, F
    Stephens, LC
    Tinkey, P
    Cromeens, D
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (07): : 729 - 733
  • [33] Laparoscopically guided bipolar radiofrequency ablation of areas of porcine liver
    S. A. Curley
    B. S. Davidson
    R. Y. Fleming
    F. Izzo
    L. C. Stephens
    P. Tinkey
    D. Cromeens
    Surgical Endoscopy , 1997, 11 : 729 - 733
  • [34] Bipolar radiofrequency ablation creates different lesion characteristics compared to simultaneous unipolar ablation
    Nguyen, Duy T.
    Zheng, Lijun
    Zipse, Matthew M.
    Borne, Ryan T.
    Tzou, Wendy S.
    Fleeman, Blake
    Sauer, William H.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2960 - 2967
  • [35] Bipolar radiofrequency ablation with 2 x 2 electrodes as a building block for matrix radiofrequency ablation: Ex vivo liver experiments and finite element method modelling
    Mulier, Stefaan
    Jiang, Yansheng
    Jamart, Jacques
    Wang, Chong
    Feng, Yuanbo
    Marchal, Guy
    Michel, Luc
    Ni, Yicheng
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2015, 31 (06) : 649 - 665
  • [36] Re: Comparisons of Monopolar Lesion Volumes with Hypertonic Saline Solution in Radiofrequency Ablation: A Randomized, Double-Blind, Ex Vivo Study
    Provenzano, David A.
    Cosman, Eric, Jr.
    Wilsey, Jared
    PAIN PHYSICIAN, 2020, 23 (04) : E425 - E427
  • [37] Radiofrequency ablation lesion detection using MR-based electrical conductivity imaging: A feasibility study of ex vivo liver experiments
    Chauhan, Munish
    Jeong, Woo Chul
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2013, 29 (07) : 643 - 652
  • [38] IN-VIVO VENTRICULAR LESION GROWTH IN RADIOFREQUENCY CATHETER ABLATION
    SIMMERS, TA
    WITTKAMPF, FHM
    HAUER, RNW
    DEMEDINA, EOR
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (03): : 523 - 531
  • [39] Comparison of wet radiofrequency ablation with dry radiofrequency ablation and radiofrequency ablation using hypertonic saline preinjection:: Ex vivo bovine liver
    Lee, JM
    Han, JK
    Kim, SH
    Shin, KS
    Lee, JY
    Park, HS
    Hur, H
    Choi, BI
    KOREAN JOURNAL OF RADIOLOGY, 2004, 5 (04) : 258 - 265
  • [40] Intrahepatic Radiofrequency Ablation Versus Electrochemical Treatment Ex Vivo
    Czymek, Ralf
    Loeffler, Stefan
    Dinter, Dorothea
    Gebhard, Maximilian
    Schmidt, Andreas
    Jungbluth, Thomas
    Kleemann, Markus
    Bruch, Hans-Peter
    Lubienski, Andreas
    JOURNAL OF SURGICAL RESEARCH, 2012, 174 (01) : 106 - 113