Bipolar radiofrequency ablation lesion areas and confluence: An ex vivo study and technical report

被引:2
|
作者
Wondra, Andrew [1 ,2 ]
Gulhar, Shelly [1 ,2 ]
Brestle, Mason D. [3 ,4 ]
Chou, Jiling [5 ]
Desai, Mehul J. [3 ,6 ,7 ]
机构
[1] MedStar Georgetown Univ, Dept Rehabil Med, Washington, DC USA
[2] MedStar Natl Rehabil Hosp, Washington, DC USA
[3] Int Spine Pain & Performance Ctr, Washington, DC USA
[4] Philadelphia Coll Osteopath Med, Suwanee, GA USA
[5] MedStar Hlth Res Inst, Hyattsville, MD USA
[6] George Washington Univ, Sch Med & Hlth Sci, Washington, DC USA
[7] Int Spine Pain & Performance Ctr, 2021 K St NW,Suite 615, Washington, DC 20006 USA
关键词
bipolar; interprobe distance; lesion confluence; lesion midpoint area; radiofrequency ablation; FACET JOINT DENERVATION; LOW-BACK-PAIN; DOUBLE-BLIND; NEUROTOMY; VOLUMES; ENERGY;
D O I
10.1111/papr.13323
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
IntroductionRadiofrequency ablation (RFA) has been used for nearly 100 years, treating an array of medical conditions including chronic pain. Radiofrequency (RF) energy depolarizes and repolarizes tissues adjacent to a probe producing heat and causing direct thermal injury. When positioned adjacent to neural structures, it leads to neural tissue injury and cell death interrupting pain signaling with the ultimate goal of providing lasting pain relief. Today, RFA is commonly used to treat cervical, thoracic, and lumbar zygapophyseal joints, sacroiliac joint, and more recently large peripheral joint-mediated pain. There are several applications of RFA systems, including bipolar, conventional thermal, cooled, protruding, and pulsed. As yet, no study has determined the best technical practice for bipolar RFA.ObjectiveThis ex vivo study examines RFA lesion midpoint (LMP) area and lesion confluence comparing three different commonly used gauge (g) probes (18-g, 20-g, and 22-g) with 10-mm active tips at various interprobe distances (IPD) to guide best technical practices for its clinical application.MethodsBipolar RFA lesions were generated in preservative-free chicken breast specimens using three different gauge probes (18-g, 20-g, and 22-g) with 10-mm active tips at various IPD (6, 8, 10, 12, 14, 16, and 18 mm). RF was applied for 105 s (15-s ramp time) at 80 degrees C for each lesion at both room and human physiological temperature. The specimen tissues were dissected through the lesion to obtain a length, width, and depth, which were used to calculate the LMP area (mm2). The LMP areas of each thermal ablation were investigated using visualization and descriptive analysis. The Kruskal-Wallis test was performed to compare LMP areas between the two temperature groups and the three different gauge probe subgroups at the various IPDs.ResultsOf the 36 RF lesions (14: 18-g, 12: 20-g, and 10: 22-g) performed, 24 demonstrated lesion confluence. The average time to reach 80 degrees C was 16-17 s; therefore, the average time of RF-energy delivery (at goal temperature) was 88-89 s despite varying needle size or IPD. Comparing the 25 and 37 degrees C groups, 18-g probes produced mean LMP areas of 73.7 and 79.2 mm2, respectively; 20-g probes produced mean LMP areas of 66 and 66.8 mm2, respectively; 22-g probes produced mean LMP areas of 56.6 and 59.7 mm2, respectively. There was no statistical evidence to state a difference regarding LMP area between temperature groups; however, the 18-g probes produced consistently larger LMP areas in the 37 degrees C compared to 25 degrees C specimen groups at each IPD. Lesion confluence was lost for 18-g, 20-g, and 22-g probes at IPD of 14, 12, and 10 mm, respectively, in both 25 and 37 degrees C groups. LMP area was similar between 6 and 8 mm IPD in all of the three-gauge groups; however, there was a significant drop in LMP area from 8 mm IPD to 10 mm and greater. The 18-g, 20-g, and 22-g probes all demonstrated a sharp decline in LMP area when increasing the IPD from 8 to 10 mm.ConclusionThis ex vivo technical study evaluated bipolar RFA LMP areas and lesion confluence, and determined the recommended IPD of 18-g, 20-g, and 22-g probes to be less than 12, 10, and 8 mm, respectively, for best clinical practice. Placing bipolar probes at an IPD greater than 14, 12, and 10 mm, respectively, risks the loss of lesion confluence and failure to produce a clinically significant treatment response due to lack of nerve capture. In clinical practice, the use of injectate may produce larger lesions than demonstrated in this study. Additionally, in vivo factors may impact ablation zone size and ablation patterns. As there are a paucity of studies comparing various RFA applications and conventional RFA needles are least expensive, it is possible that bipolar conventional RFA is more cost-effective than other techniques.
引用
收藏
页码:489 / 501
页数:13
相关论文
共 50 条
  • [21] Catheter contact area strongly correlates with lesion area in radiofrequency cardiac ablation: an ex vivo porcine heart study
    Kriengsak Masnok
    Nobuo Watanabe
    Journal of Interventional Cardiac Electrophysiology, 2022, 63 : 561 - 572
  • [22] Impedance, power, and current in radiofrequency ablation: Insights from technical, ex vivo, and clinical studies
    Bourier, Felix
    Ramirez, Francisco Daniel
    Martin, Claire A.
    Vlachos, Konstantinos
    Frontera, Antonio
    Takigawa, Masateru
    Kitamura, Takeshi
    Lam, Anna
    Duchateau, Josselin
    Pambrun, Thomas
    Cheniti, Ghassen
    Derval, Nicolas
    Denis, Arnaud
    Sacher, Frederic
    Hocini, Meleze
    Haissaguerre, Michel
    Jais, Pierre
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (11) : 2836 - 2845
  • [23] An ex-vivo experimental study on optimization of bipolar radiofrequency liver ablation using perfusion-cooled electrodes
    Lee, JM
    Han, JK
    Kim, SH
    Lee, JY
    Shin, KS
    Choi, BI
    ACTA RADIOLOGICA, 2005, 46 (05) : 443 - 451
  • [24] Hepatic bipolar radiofrequency ablation using perfused-cooled electrodes:: a comparative study in the ex vivo bovine liver
    Lee, JM
    Han, JK
    Kim, SH
    Lee, JY
    Choi, SH
    Choi, BI
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (923): : 944 - 949
  • [25] Ex Vivo Experimental Study of the Ablation Area of Bovine Liver Using STARmed Radiofrequency Ablation
    Ishikawa, Toru
    Hasegawa, Iori
    Hirosawa, Hiroshi
    Honmou, Tsubasa
    Sakai, Nobuyuki
    Igarashi, Takanori
    Yamazaki, Shun
    Kobayashi, Takamasa
    Sato, Toshifumi
    Iwanaga, Akito
    Sano, Tomoe
    Yokoyama, Junji
    Honma, Terasu
    IN VIVO, 2023, 37 (03): : 1047 - 1051
  • [26] Bipolar Radiofrequency Ablation for Nodular Thyroid Disease-Ex Vivo and In Vivo Evaluation of a Dose-Response Relationship
    Holmer, Christoph
    Lehmann, Kai S.
    Knappe, Verena
    Zurbuchen, Urte
    Frericks, Bernd
    Schumann, Thomas
    Buhr, Heinz J.
    Ritz, Joerg-Peter
    JOURNAL OF SURGICAL RESEARCH, 2011, 169 (02) : 234 - 240
  • [27] Comparisons of Monopolar Lesion Volumes with Hypertonic Saline Solution in Radiofrequency Ablation: A Randomized, Double-Blind, Ex Vivo Study
    Paul, Christopher
    Suvar, Tolga
    Goree, Johnathan
    Sanford, Joseph
    Srinivasan, Nivetha
    Choi, Heejung
    PAIN PHYSICIAN, 2020, 23 (02) : 159 - 164
  • [28] Optimization of Direct Current-Enhanced Radiofrequency Ablation: An Ex Vivo Study
    Tanaka, Toshihiro
    Isfort, Peter
    Bruners, Philipp
    Penzkofer, Tobias
    Kichikawa, Kimihiko
    Schmitz-Rode, Thomas
    Mahnken, Andreas H.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (05) : 1028 - 1032
  • [29] Algorithm Optimization for Multitined Radiofrequency Ablation: Comparative Study in ex Vivo and in Vivo Bovine Liver
    Appelbaum, Liat
    Sosna, Jacob
    Pearson, Robert
    Perez, Sarah
    Nissenbaum, Yizhak
    Mertyna, Pawel
    Libson, Eugene
    Goldberg, S. Nahum
    RADIOLOGY, 2010, 254 (02) : 430 - 440
  • [30] Newly Designed Flexible Electrode for Laparoscopic Radiofrequency Ablation: Ex Vivo and In Vivo Comparative Studies with Needle Electrode in a Porcine Liver as Technical Study
    Ko, Heung Kyu
    Kim, Hyun Beom
    Kang, Chang Moo
    Choi, Jin Young
    Kim, Ah Hyun
    Won, Jong Yun
    Lee, Jong Tae
    JOURNAL OF SURGICAL RESEARCH, 2011, 168 (01) : 88 - 96