Efficient estimation of tuned liquid column damper inerter (TLCDI) parameters for seismic control of base-isolated structures

被引:14
|
作者
Masnata, Chiara [1 ]
Di Matteo, Alberto [1 ]
Adam, Christoph [2 ]
Pirrotta, Antonina [1 ]
机构
[1] Univ Palermo, Dept Engn, Palermo, Italy
[2] Univ Innsbruck, Unit Appl Mech, Technikerstr 13, Innsbruck, Austria
关键词
VIBRATION CONTROL; MASS DAMPERS; EARTHQUAKE RESPONSE; OPTIMAL-DESIGN; HYBRID CONTROL; SYSTEMS;
D O I
10.1111/mice.12929
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents an enhanced base-isolation (BI) system equipped with a novel passive control device composed of a tuned liquid damper and an inerter (TLCDI). With the aim of reducing the seismic response of BI systems, this contribution focuses on the design of the TLCDI providing analytical solutions for the optimal TLCDI parameters, easily implementable in the design phase. The effectiveness of the proposed approach in terms of seismic response reduction and computational gain is validated by comparison with classical numerical optimization techniques. The control performance of two different base-isolated TLCDI-controlled structures is assessed by employing real-ground motion records, and relevant comparisons with both uncontrolled base-isolated structures and equipped with a conventional TLCD are presented.
引用
收藏
页码:1638 / 1656
页数:19
相关论文
共 50 条