Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures

被引:3
|
作者
Kang, Xiaofang [1 ]
Wu, Jian [1 ]
Wang, Xinqi [1 ]
Lei, Shancheng [2 ]
机构
[1] Anhui Jianzhu Univ, Sch Civil Engn, Key Lab Intelligent Underground Detect Technol, Hefei 230601, Peoples R China
[2] Changsha Univ Sci & Technol, Chengnan Coll, Changsha 410015, Peoples R China
来源
关键词
Adjacent buildings; tuned inerter damper (TID); H2 norm optimization; vibration control; energy harvesting; VIBRATION CONTROL; MASS-DAMPER; ROTATIONAL INERTIA; OPTIMAL-DESIGN;
D O I
10.32604/cmes.2023.029044
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to improve the seismic performance of adjacent buildings, two types of tuned inerter damper (TID) damping systems for adjacent buildings are proposed, which are composed of springs, inerter devices and dampers in serial or in parallel. The dynamic equations of TID adjacent building damping systems were derived, and the H2 norm criterion was used to optimize and adjust them, so that the system had the optimum damping performance under white noise random excitation. Taking TID frequency ratio and damping ratio as optimization parameters, the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained. The results showed that compared with the classic TMD, TID could obtain a better damping effect in the adjacent buildings. Comparing the TIDs composed of serial or parallel, it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response, while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller. Taking the adjacent building composed of two ten-story frame structures as an example, the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out. It was found that TID had a better damping effect in the full-time range compared with the classic TMD. This paper also studied the potential power of TID in adjacent buildings, which can be converted into available power resources during earthquakes.
引用
收藏
页码:551 / 593
页数:43
相关论文
共 50 条
  • [1] Seismic responses of adjacent bridge structures coupled by tuned inerter damper
    Song, Jian
    Bi, Kaiming
    Xu, Kun
    Han, Qiang
    Du, Xiuli
    ENGINEERING STRUCTURES, 2021, 243
  • [2] Seismic responses of adjacent bridge structures coupled by tuned inerter damper
    Song, Jian
    Bi, Kaiming
    Xu, Kun
    Han, Qiang
    Du, Xiuli
    Engineering Structures, 2021, 243
  • [3] Optimal design and performance evaluation of tuned mass damper inerter in building structures
    Caicedo, Daniel
    Lara-Valencia, Luis
    Bland, John
    REVISTA FACULTAD DE INGENIERIA-UNIVERSIDAD DE ANTIOQUIA, 2023, (106): : 66 - 77
  • [4] Performance and efficiency oriented optimal design of tuned inerter damper for seismic response control of building structures
    Hao, Linfei
    He, Hui
    Tan, Ping
    Jin, Kiwoong
    Liu, Xinyu
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2023, 253
  • [5] Risk-informed optimization of the tuned mass-damper-inerter (TMDI) for the seismic protection of multi-storey building structures
    Ruiz, R.
    Taflanidis, A. A.
    Giaralis, A.
    Lopez-Garcia, D.
    ENGINEERING STRUCTURES, 2018, 177 : 836 - 850
  • [6] The Seismic Mitigation Design of Tuned Inerter Damper for Building Structure
    Liu L.
    Tan P.
    Yan W.
    Zhou F.
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2018, 38 (04): : 751 - 757
  • [7] Optimum Parameters of Tuned Inerter Damper for Damped Structures
    Ul Islam, Naqeeb
    Jangid, R. S.
    JOURNAL OF SOUND AND VIBRATION, 2022, 537
  • [8] Optimum design and performance evaluation of the tuned inerter-negative-stiffness damper for seismic protection of single-degree-of-freedom structures
    Wang, Hao
    Gao, Hui
    Li, Jian
    Wang, Zhihao
    Ni, Youhao
    Liang, Ruijun
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2021, 212
  • [9] Optimal Tuned Inerter Dampers for Vibration Control Performance of Adjacent Building Structures
    Kang, Xiaofang
    Tang, Jianjun
    Li, Feng
    Wu, Jian
    Wei, Jiachen
    Huang, Qiwen
    Li, Zhi
    Zhang, Fuyi
    Sheng, Ziyi
    BUILDINGS, 2023, 13 (07)
  • [10] Statistical seismic performance assessment of tuned mass damper inerter
    Kaveh, Ali
    Farzam, Maziar Fahimi
    Jalali, Himan Hojat
    STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (10):