Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures

被引:3
|
作者
Kang, Xiaofang [1 ]
Wu, Jian [1 ]
Wang, Xinqi [1 ]
Lei, Shancheng [2 ]
机构
[1] Anhui Jianzhu Univ, Sch Civil Engn, Key Lab Intelligent Underground Detect Technol, Hefei 230601, Peoples R China
[2] Changsha Univ Sci & Technol, Chengnan Coll, Changsha 410015, Peoples R China
来源
关键词
Adjacent buildings; tuned inerter damper (TID); H2 norm optimization; vibration control; energy harvesting; VIBRATION CONTROL; MASS-DAMPER; ROTATIONAL INERTIA; OPTIMAL-DESIGN;
D O I
10.32604/cmes.2023.029044
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to improve the seismic performance of adjacent buildings, two types of tuned inerter damper (TID) damping systems for adjacent buildings are proposed, which are composed of springs, inerter devices and dampers in serial or in parallel. The dynamic equations of TID adjacent building damping systems were derived, and the H2 norm criterion was used to optimize and adjust them, so that the system had the optimum damping performance under white noise random excitation. Taking TID frequency ratio and damping ratio as optimization parameters, the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained. The results showed that compared with the classic TMD, TID could obtain a better damping effect in the adjacent buildings. Comparing the TIDs composed of serial or parallel, it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response, while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller. Taking the adjacent building composed of two ten-story frame structures as an example, the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out. It was found that TID had a better damping effect in the full-time range compared with the classic TMD. This paper also studied the potential power of TID in adjacent buildings, which can be converted into available power resources during earthquakes.
引用
收藏
页码:551 / 593
页数:43
相关论文
共 50 条
  • [21] Seismic protection of land-based wind turbine towers using the tuned inerter damper
    Alotta, Gioacchino
    Biondo, Chiara
    Giaralis, Agathoklis
    Failla, Giuseppe
    STRUCTURES, 2023, 51 : 640 - 656
  • [22] Analytical optimal design and performance evaluation of series tuned inerter damper for ground motion excited structures
    Zhang, Ruoyu
    Huang, Jizhong
    Cao, Meigen
    ARCHIVE OF APPLIED MECHANICS, 2024, 94 (06) : 1739 - 1752
  • [23] Vibration isolation performance and optimization design of a tuned inerter negative stiffness damper
    Tai, Yu-ji
    Wang, Hai-dong
    Chen, Zhi-qiang
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2023, 241
  • [24] Tuned inerter damper for adjacent bridges vibration control considering nonlinearities
    Song, Jian
    Fang, Xiaojun
    Bi, Kaiming
    Ding, Hao
    Qin, Huailei
    ENGINEERING STRUCTURES, 2025, 325
  • [25] Optimum design and performance evaluation of inerter-based dampers for seismic protection of adjacent bridges
    Song, Jian
    Bi, Kaiming
    Ma, Ruisheng
    Xu, Kun
    Han, Qiang
    STRUCTURES, 2023, 55 : 1277 - 1291
  • [26] Optimum parameters of tuned mass damper-inerter for damped structure under seismic excitation
    Shiv Prakash
    R. S. Jangid
    International Journal of Dynamics and Control, 2022, 10 : 1322 - 1336
  • [27] Optimum parameters of tuned mass damper-inerter for damped structure under seismic excitation
    Prakash, Shiv
    Jangid, R. S.
    INTERNATIONAL JOURNAL OF DYNAMICS AND CONTROL, 2022, 10 (05) : 1322 - 1336
  • [28] Assessment of the tuned mass damper inerter for seismic response control of base-isolated structures
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (02):
  • [29] Optimal design and seismic performance of Multi-Tuned Mass Damper Inerter (MTMDI) applied to adjacent high-rise buildings
    De Domenico, Dario
    Qiao, Haoshuai
    Wang, Qinhua
    Zhu, Zhiwen
    Marano, Giuseppe
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (14):
  • [30] Optimal design and performance evaluation of systems with Tuned Mass Damper Inerter (TMDI)
    Pietrosanti, D.
    De Angelis, M.
    Basili, M.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (08): : 1367 - 1388