Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures

被引:3
|
作者
Kang, Xiaofang [1 ]
Wu, Jian [1 ]
Wang, Xinqi [1 ]
Lei, Shancheng [2 ]
机构
[1] Anhui Jianzhu Univ, Sch Civil Engn, Key Lab Intelligent Underground Detect Technol, Hefei 230601, Peoples R China
[2] Changsha Univ Sci & Technol, Chengnan Coll, Changsha 410015, Peoples R China
来源
关键词
Adjacent buildings; tuned inerter damper (TID); H2 norm optimization; vibration control; energy harvesting; VIBRATION CONTROL; MASS-DAMPER; ROTATIONAL INERTIA; OPTIMAL-DESIGN;
D O I
10.32604/cmes.2023.029044
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to improve the seismic performance of adjacent buildings, two types of tuned inerter damper (TID) damping systems for adjacent buildings are proposed, which are composed of springs, inerter devices and dampers in serial or in parallel. The dynamic equations of TID adjacent building damping systems were derived, and the H2 norm criterion was used to optimize and adjust them, so that the system had the optimum damping performance under white noise random excitation. Taking TID frequency ratio and damping ratio as optimization parameters, the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained. The results showed that compared with the classic TMD, TID could obtain a better damping effect in the adjacent buildings. Comparing the TIDs composed of serial or parallel, it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response, while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller. Taking the adjacent building composed of two ten-story frame structures as an example, the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out. It was found that TID had a better damping effect in the full-time range compared with the classic TMD. This paper also studied the potential power of TID in adjacent buildings, which can be converted into available power resources during earthquakes.
引用
收藏
页码:551 / 593
页数:43
相关论文
共 50 条
  • [41] Closed-form optimization of tuned mass-damper-inerter (TMDI) in flexible structures
    Zhang, Zili
    Chen, Bei
    Hua, Xugang
    JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [42] Seismic performance of optimal Multi-Tuned Liquid Column Damper-Inerter (MTLCDI) applied to adjacent high-rise buildings
    Wang, Qinhua
    Qiao, Haoshuai
    De Domenico, Dario
    Zhu, Zhiwen
    Tang, Yi
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 143
  • [43] Effects of play and inerter nonlinearities on the performance of tuned mass damper
    Brzeski, P.
    Perlikowski, P.
    NONLINEAR DYNAMICS, 2017, 88 (02) : 1027 - 1041
  • [44] Effects of play and inerter nonlinearities on the performance of tuned mass damper
    P. Brzeski
    P. Perlikowski
    Nonlinear Dynamics, 2017, 88 : 1027 - 1041
  • [45] Performance of Numerically Optimized Tuned Mass Damper with Inerter (TMDI)
    Weber, Felix
    Borchsenius, Fredrik
    Distl, Johann
    Braun, Christian
    APPLIED SCIENCES-BASEL, 2022, 12 (12):
  • [46] Evaluation of a pendulum pounding tuned mass damper for seismic control of structures
    Wang, Wenxi
    Yang, Zhilin
    Hua, Xugang
    Chen, Zhengqing
    Wang, Xiuyong
    Song, Gangbing
    ENGINEERING STRUCTURES, 2021, 228
  • [47] An inerter-based electromagnetic damper for civil structures: Modeling, testing, and seismic performance
    Shen, Wenai
    Long, Zhentao
    Cai, Long
    Niyitangamahoro, Abdou
    Zhu, Hongping
    Li, Yamin
    Qiu, Canxing
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 173
  • [48] Seismic Control of Story Isolation System Using Tuned Mass Damper Inerter
    Liang, Qigang
    Wei, Jinyuan
    Li, Luyu
    JOURNAL OF ENGINEERING MECHANICS, 2023, 149 (03)
  • [49] A tuned rocking wall damper enhanced by an inerter to control the seismic vibration of existing mid-rise structures
    Ogail, Emadeldin
    Wu, Hao
    Lu, Zheng
    ENGINEERING STRUCTURES, 2025, 324
  • [50] Parametric optimization of electromagnetic tuned inerter damper for structural vibration suppression
    Luo, Yifan
    Sun, Hongxin
    Wang, Xiuyong
    Chen, Anhua
    Zuo, Lei
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (05):