Efficient estimation of tuned liquid column damper inerter (TLCDI) parameters for seismic control of base-isolated structures

被引:14
|
作者
Masnata, Chiara [1 ]
Di Matteo, Alberto [1 ]
Adam, Christoph [2 ]
Pirrotta, Antonina [1 ]
机构
[1] Univ Palermo, Dept Engn, Palermo, Italy
[2] Univ Innsbruck, Unit Appl Mech, Technikerstr 13, Innsbruck, Austria
关键词
VIBRATION CONTROL; MASS DAMPERS; EARTHQUAKE RESPONSE; OPTIMAL-DESIGN; HYBRID CONTROL; SYSTEMS;
D O I
10.1111/mice.12929
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents an enhanced base-isolation (BI) system equipped with a novel passive control device composed of a tuned liquid damper and an inerter (TLCDI). With the aim of reducing the seismic response of BI systems, this contribution focuses on the design of the TLCDI providing analytical solutions for the optimal TLCDI parameters, easily implementable in the design phase. The effectiveness of the proposed approach in terms of seismic response reduction and computational gain is validated by comparison with classical numerical optimization techniques. The control performance of two different base-isolated TLCDI-controlled structures is assessed by employing real-ground motion records, and relevant comparisons with both uncontrolled base-isolated structures and equipped with a conventional TLCD are presented.
引用
收藏
页码:1638 / 1656
页数:19
相关论文
共 50 条
  • [21] Performance improvement and demand-oriented optimum design of the tuned negative stiffness inerter damper for base-isolated structures
    Gao, Hui
    Xing, Chenxi
    Wang, Hao
    Li, Jian
    Zhang, Yang
    JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [22] Optimum design and performance of a base-isolated structure with tuned mass negative stiffness inerter damper
    Kiran, K. K.
    Al-Osta, Mohammed A.
    Ahmad, Shamsad
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [23] Effect of tuned mass damper on displacement demand of base-isolated structures
    Taniguchi, Tomoyo
    Der Kiureghian, Armen
    Melkumyan, Mikayel
    ENGINEERING STRUCTURES, 2008, 30 (12) : 3478 - 3488
  • [24] Optimum design and performance of a base-isolated structure with tuned mass negative stiffness inerter damper
    K. K. Kiran
    Mohammed A. Al-Osta
    Shamsad Ahmad
    Scientific Reports, 13
  • [25] Seismic performance improvement of base-isolated structures using a semi-active tuned mass damper
    Wang, Liangkun
    Nagarajaiah, Satish
    Shi, Weixing
    Zhou, Ying
    ENGINEERING STRUCTURES, 2022, 271
  • [26] Clutching Inerter Damper for Multidegree-of-Freedom Base-Isolated Structures: A Numerical Study
    Cupp, Wyatt
    Wierschem, Nicholas E.
    JOURNAL OF ENGINEERING MECHANICS, 2024, 150 (07)
  • [27] Tuned liquid column ball damper for seismic vibration control
    Gur, Sourav
    Roy, Koushik
    Mishra, Sudib Kumar
    STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (11): : 1325 - 1342
  • [28] Smart structures through nontraditional design of Tuned Mass Damper Inerter for higher control of base isolated systems
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    MECHANICS RESEARCH COMMUNICATIONS, 2020, 105
  • [29] Inerter-based tuned liquid column damper for seismic vibration control of a single-degree-of-freedom structure
    Wang, Qinhua
    Tiwari, Nayan Deep
    Qiao, Haoshuai
    Wang, Quan
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2020, 184
  • [30] Performance of clutched inerter damper for base-isolated structures under near-fault motions
    Barkale, Shubham
    Jangid, R. S.
    ENGINEERING RESEARCH EXPRESS, 2022, 4 (03):