Evaluation of a novel device to assess obstructive sleep apnea and body position

被引:3
|
作者
Raphelson, Janna Rae [1 ,8 ]
Ahmed, Imran M. [2 ]
Ancoli-Israel, Sonia [3 ]
Ojile, Joseph [4 ,5 ]
Pearson, Suzanne [6 ]
Bennett, Nathan [7 ]
Uhles, Matthew Lee [5 ]
Rohrscheib, Chelsie [7 ]
Malhotra, Atul [1 ]
机构
[1] Univ Calif San Diego, Div Pulm Crit Care & Sleep Med & Physiol, La Jolla, CA USA
[2] Albert Einstein Coll Med, Montefiore Med Ctr, Bronx, NY USA
[3] Univ Calif San Diego, Dept Psychiat, La Jolla, CA USA
[4] St Louis Univ, Sch Med, St Louis Univ Hosp, St Louis, MO USA
[5] Clayton Sleep Inst, St Louis, MO USA
[6] Valley Hlth Syst, Ridgewood, NJ USA
[7] Wesper Inc, New York, NY USA
[8] 9500 Gilman Dr, La Jolla, CA 92093 USA
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2023年 / 19卷 / 09期
基金
美国国家卫生研究院;
关键词
obstructive sleep apnea; sleep diagnostics; polysomnography; sleep testing; AIRWAY PRESSURE; POLYSOMNOGRAPHY; DIAGNOSIS;
D O I
10.5664/jcsm.10644
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Obstructive sleep apnea is a prevalent disease with well-known complications when left untreated. Advances in sleep-disordered breathing diagnosis may increase detection and appropriate treatment. The Wesper device is a recently developed portable system with specialized wearable patches that can measure respiratory effort, derived airflow, estimated air pressure, and body position. This study sought to compare the diagnostic ability of the novel Wesper device with the gold standard of polysomnography.Methods: Patients enrolled in the study underwent simultaneous polysomnography and Wesper device testing in a sleep laboratory setting. Data were collected and scored by readers blinded to all patient information, and the primary reader was blinded to testing method. The accuracy of the Wesper device was determined by calculation of the Pearson correlation and Bland-Altman limits of agreement of apnea-hypopnea indices between testing methods. Adverse events were also recorded.Results: A total of 53 patients were enrolled in the study and 45 patients were included in the final analysis. Pearson correlation between polysomnography and Wesper device apnea-hypopnea index determinations was 0.951, which met the primary endpoint goal (P = .0003). The Bland-Altman 95% limits of agreement were 28.05 and 6.38, which also met the endpoint goal (P < .001). There were no adverse events or serious adverse events noted.Conclusions: The Wesper device compares favorably with gold-standard polysomnography. Given the lack of safety concerns, we advocate for further study regarding its utility in diagnosis and management of sleep apnea in the future.
引用
收藏
页码:1643 / 1649
页数:7
相关论文
共 50 条
  • [41] Effect of prone position on apnea severity in obstructive sleep apnea
    Matsuzawa, Y
    Hayashi, S
    Yamaguchi, S
    Yoshikawa, S
    Okada, K
    Fujimoto, K
    Sekiguchi, M
    INTERNAL MEDICINE, 1995, 34 (12) : 1190 - 1193
  • [42] INNOVATIVE METHODOLOGY AND DEVICE DETECTING HEAD POSITION FOR THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA AND SNORING
    Aghassi, Payam
    Sailer, Stacia
    Lyons, Christopher
    Lawee, Michael
    SLEEP, 2019, 42
  • [43] The effect of sleep position on sleep bruxism in adults with obstructive sleep apnea
    Kuang, Boyuan
    Lobbezoo, Frank
    Li, Deshui
    Hilgevoord, Antonius A. J.
    de Vries, Nico
    Aarab, Ghizlane
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (07) : 1207 - 1212
  • [44] SLEEP BODY POSITION CORRELATES WITH COGNITIVE PERFORMANCE IN MIDDLE AGE OBSTRUCTIVE SLEEP APNEA SUBJECTS.
    Girolami, S.
    Tardio, M.
    Serpetti, L.
    Di Mattia, N.
    Micheletti, P.
    Di Napoli, M.
    Scutti, A.
    SLEEP MEDICINE, 2022, 100 : S8 - S8
  • [45] Effects of body position on sleep architecture and quality in subsyndromal adults without apparent obstructive sleep apnea
    Kutbay Ozcelik, Hatice
    Bayram, Mehmet
    Doganay, Emine
    Kart, Levent
    Sezer, Murat
    Akkoyunlu, Muhammed Emin
    Karakose, Fatmanur
    Yakar, Fatih
    SLEEP AND BIOLOGICAL RHYTHMS, 2015, 13 (03) : 279 - 286
  • [46] Effects of body position on sleep architecture and quality in subsyndromal adults without apparent obstructive sleep apnea
    Hatice Kutbay Özçelik
    Mehmet Bayram
    Emine Doganay
    Levent Kart
    Murat Sezer
    Muhammed Emin Akkoyunlu
    Fatmanur Karaköse
    Fatih Yakar
    Sleep and Biological Rhythms, 2015, 13 : 279 - 286
  • [47] Evaluation of the Impact of Body Position on Primary Central Sleep Apnea Syndrome
    Arslan, Burcu Oktay
    Hosgor, Zeynep Zeren Ucar
    Ekinci, Selim
    Cetinkol, Isil
    ARCHIVOS DE BRONCONEUMOLOGIA, 2021, 57 (06): : 393 - 398
  • [48] EFFECT OF DISEASE SEVERITY ON DETERMINING BODY POSITION DURING SLEEP IN PATIENTS WITH POSITIONAL OBSTRUCTIVE SLEEP APNEA
    Kaur, A.
    Verma, R.
    Gandhi, A.
    Riaz, S.
    Vega-Sanchez, M.
    Jaffe, F.
    Yu, D.
    Chatila, W.
    D'alonzo, G.
    Weaver, S.
    Shariff, T.
    Krachman, S.
    SLEEP, 2017, 40 : A233 - A233
  • [49] Body position and obstructive sleep apnea in 8-12-month-old infants
    Pereira, Kevin D.
    Rathi, Nisha K.
    Fatakia, Adil
    Haque, Sajid A.
    Castriotta, Richard J.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2008, 72 (06) : 897 - 900
  • [50] DIAPHRAGMATIC RESPONSES TO BODY POSITION CHANGES IN OBESE PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA
    SHARP, JT
    DRUZ, WS
    KONDRAGUNTA, VR
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (01): : 32 - 37