Evaluation of a novel device to assess obstructive sleep apnea and body position

被引:3
|
作者
Raphelson, Janna Rae [1 ,8 ]
Ahmed, Imran M. [2 ]
Ancoli-Israel, Sonia [3 ]
Ojile, Joseph [4 ,5 ]
Pearson, Suzanne [6 ]
Bennett, Nathan [7 ]
Uhles, Matthew Lee [5 ]
Rohrscheib, Chelsie [7 ]
Malhotra, Atul [1 ]
机构
[1] Univ Calif San Diego, Div Pulm Crit Care & Sleep Med & Physiol, La Jolla, CA USA
[2] Albert Einstein Coll Med, Montefiore Med Ctr, Bronx, NY USA
[3] Univ Calif San Diego, Dept Psychiat, La Jolla, CA USA
[4] St Louis Univ, Sch Med, St Louis Univ Hosp, St Louis, MO USA
[5] Clayton Sleep Inst, St Louis, MO USA
[6] Valley Hlth Syst, Ridgewood, NJ USA
[7] Wesper Inc, New York, NY USA
[8] 9500 Gilman Dr, La Jolla, CA 92093 USA
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2023年 / 19卷 / 09期
基金
美国国家卫生研究院;
关键词
obstructive sleep apnea; sleep diagnostics; polysomnography; sleep testing; AIRWAY PRESSURE; POLYSOMNOGRAPHY; DIAGNOSIS;
D O I
10.5664/jcsm.10644
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Obstructive sleep apnea is a prevalent disease with well-known complications when left untreated. Advances in sleep-disordered breathing diagnosis may increase detection and appropriate treatment. The Wesper device is a recently developed portable system with specialized wearable patches that can measure respiratory effort, derived airflow, estimated air pressure, and body position. This study sought to compare the diagnostic ability of the novel Wesper device with the gold standard of polysomnography.Methods: Patients enrolled in the study underwent simultaneous polysomnography and Wesper device testing in a sleep laboratory setting. Data were collected and scored by readers blinded to all patient information, and the primary reader was blinded to testing method. The accuracy of the Wesper device was determined by calculation of the Pearson correlation and Bland-Altman limits of agreement of apnea-hypopnea indices between testing methods. Adverse events were also recorded.Results: A total of 53 patients were enrolled in the study and 45 patients were included in the final analysis. Pearson correlation between polysomnography and Wesper device apnea-hypopnea index determinations was 0.951, which met the primary endpoint goal (P = .0003). The Bland-Altman 95% limits of agreement were 28.05 and 6.38, which also met the endpoint goal (P < .001). There were no adverse events or serious adverse events noted.Conclusions: The Wesper device compares favorably with gold-standard polysomnography. Given the lack of safety concerns, we advocate for further study regarding its utility in diagnosis and management of sleep apnea in the future.
引用
收藏
页码:1643 / 1649
页数:7
相关论文
共 50 条
  • [31] The Effect Of Body Position On Dynamic Loop Gain In Obstructive Sleep Apnea Patients
    Joosten, S. A.
    Mann, D.
    Landry, S.
    Sands, S. A.
    Terrill, P.
    Hamilton, G. S.
    Edwards, B. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [32] EFFECTS OF BODY POSITION ON THE UPPER AIRWAY OF PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA
    PEVERNAGIE, DA
    STANSON, AW
    SHEEDY, PF
    DANIELS, BK
    SHEPARD, JW
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (01) : 179 - 185
  • [33] A NOVEL MOUTHPIECE DEVICE DESIGN FOR THE TREATMENT OF OBSTRUCTIVE SLEEP APNEA SYNDROME
    Zulfikar, S.
    Kirisoglu, C. E.
    Dincer, A.
    Guvenis, A.
    Kocaturk, O.
    SLEEP, 2017, 40 : A207 - A207
  • [34] Effect of Body Position and Sleep State on Obstructive Sleep Apnea Severity in Children with Down Syndrome
    Nisbet, Lauren C.
    Phillips, Nicole N.
    Hoban, Timothy F.
    O'Brien, Louise M.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2014, 10 (01): : 81 - 88
  • [35] Tolerability and safety of a novel tongue advancement device for obstructive sleep apnea
    Stuck, B. A.
    Baisch, A.
    Hamans, E.
    Hoermann, K.
    Maurer, J. T.
    SLEEP, 2008, 31 : A157 - A157
  • [36] ECONOMIC EVALUATION OF MANDIBULAR ADVANCEMENT DEVICE TO TREAT OBSTRUCTIVE SLEEP APNEA
    Giannopoulou, A.
    Burgers, L. T.
    van Bruggen, M. P. B.
    de Vries, N.
    Redekop, W. K.
    Rijnsburger, A.
    VALUE IN HEALTH, 2013, 16 (07) : A373 - A373
  • [37] VALIDATION OF A NOVEL WEARABLE HOME SLEEP TESTING DEVICE FOR ASSESSMENT OF OBSTRUCTIVE SLEEP APNEA
    Yeh, E.
    Wong, E.
    Strohl, K.
    Gu, W.
    Tsai, C.
    Leung, L.
    Yar, W.
    Chiang, A.
    SLEEP, 2020, 43 : A459 - A460
  • [38] Evaluation of body position in upper airway stimulation for obstructive sleep apnea-is continuous voltage sufficient enough?
    Steffen, Armin
    Hartmann, Julia T.
    Koenig, Inke R.
    Ravesloot, Madeline J. L.
    Hofauer, Benedikt
    Heiser, Clemens
    SLEEP AND BREATHING, 2018, 22 (04) : 1207 - 1212
  • [39] Evaluation of a Single-Channel Nasal Pressure Device to Assess Obstructive Sleep Apnea Risk in Laboratory and Home Environments
    Crowley, Kate E.
    Rajaratnam, Shantha M. W.
    Shea, Steven A.
    Epstein, Lawrence J.
    Czeisler, Charles A.
    Lockley, Steven W.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (02): : 109 - 116
  • [40] Condylar Position in the Treatment of Obstructive Sleep Apnea with a Mandibular Advancement Device: A Pilot Study
    Gurgel, Marcela
    Kurita, Lucio
    Fonteles, Cristiane
    Ribeiro, Thyciana
    Costa, Fabio
    Freitas, Benedito
    Bruin, Veralice
    Cevidanes, Lucia
    Chaves-Junior, Cauby
    SLEEP SCIENCE, 2023, 16 (04) : 381 - 388