Evaluation of a novel device to assess obstructive sleep apnea and body position

被引:3
|
作者
Raphelson, Janna Rae [1 ,8 ]
Ahmed, Imran M. [2 ]
Ancoli-Israel, Sonia [3 ]
Ojile, Joseph [4 ,5 ]
Pearson, Suzanne [6 ]
Bennett, Nathan [7 ]
Uhles, Matthew Lee [5 ]
Rohrscheib, Chelsie [7 ]
Malhotra, Atul [1 ]
机构
[1] Univ Calif San Diego, Div Pulm Crit Care & Sleep Med & Physiol, La Jolla, CA USA
[2] Albert Einstein Coll Med, Montefiore Med Ctr, Bronx, NY USA
[3] Univ Calif San Diego, Dept Psychiat, La Jolla, CA USA
[4] St Louis Univ, Sch Med, St Louis Univ Hosp, St Louis, MO USA
[5] Clayton Sleep Inst, St Louis, MO USA
[6] Valley Hlth Syst, Ridgewood, NJ USA
[7] Wesper Inc, New York, NY USA
[8] 9500 Gilman Dr, La Jolla, CA 92093 USA
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2023年 / 19卷 / 09期
基金
美国国家卫生研究院;
关键词
obstructive sleep apnea; sleep diagnostics; polysomnography; sleep testing; AIRWAY PRESSURE; POLYSOMNOGRAPHY; DIAGNOSIS;
D O I
10.5664/jcsm.10644
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Obstructive sleep apnea is a prevalent disease with well-known complications when left untreated. Advances in sleep-disordered breathing diagnosis may increase detection and appropriate treatment. The Wesper device is a recently developed portable system with specialized wearable patches that can measure respiratory effort, derived airflow, estimated air pressure, and body position. This study sought to compare the diagnostic ability of the novel Wesper device with the gold standard of polysomnography.Methods: Patients enrolled in the study underwent simultaneous polysomnography and Wesper device testing in a sleep laboratory setting. Data were collected and scored by readers blinded to all patient information, and the primary reader was blinded to testing method. The accuracy of the Wesper device was determined by calculation of the Pearson correlation and Bland-Altman limits of agreement of apnea-hypopnea indices between testing methods. Adverse events were also recorded.Results: A total of 53 patients were enrolled in the study and 45 patients were included in the final analysis. Pearson correlation between polysomnography and Wesper device apnea-hypopnea index determinations was 0.951, which met the primary endpoint goal (P = .0003). The Bland-Altman 95% limits of agreement were 28.05 and 6.38, which also met the endpoint goal (P < .001). There were no adverse events or serious adverse events noted.Conclusions: The Wesper device compares favorably with gold-standard polysomnography. Given the lack of safety concerns, we advocate for further study regarding its utility in diagnosis and management of sleep apnea in the future.
引用
收藏
页码:1643 / 1649
页数:7
相关论文
共 50 条
  • [21] Association of body position with sleep architecture and respiratory disturbances in children with obstructive sleep apnea
    Zhang, Xiao-Wen
    Li, Yuan
    Zhou, Feng
    Guo, Chang-Kai
    Huang, Zhao-Tong
    ACTA OTO-LARYNGOLOGICA, 2007, 127 (12) : 1321 - 1326
  • [22] Influence of the device used for obstructive sleep apnea diagnosis on body position: a comparison between polysomnography and portable monitor
    Mello, Andre A. F.
    D'Angelo, Giovanna
    Santos, Ronaldo B.
    Bensenor, Isabela
    Lotufo, Paulo A.
    Lorenzi-Filho, Geraldo
    Drager, Luciano F.
    Genta, Pedro R.
    SLEEP AND BREATHING, 2023, 27 (03) : 887 - 891
  • [23] Influence of the device used for obstructive sleep apnea diagnosis on body position: a comparison between polysomnography and portable monitor
    André A. F. Mello
    Giovanna D´Angelo
    Ronaldo B. Santos
    Isabela Bensenor
    Paulo A. Lotufo
    Geraldo Lorenzi-Filho
    Luciano F. Drager
    Pedro R. Genta
    Sleep and Breathing, 2023, 27 : 887 - 891
  • [24] Evaluation of body position in upper airway stimulation for obstructive sleep apnea—is continuous voltage sufficient enough?
    Armin Steffen
    Julia T. Hartmann
    Inke R. König
    Madeline J. L. Ravesloot
    Benedikt Hofauer
    Clemens Heiser
    Sleep and Breathing, 2018, 22 : 1207 - 1212
  • [25] Evaluation of a Novel Device for Measuring Patient Compliance with Oral Appliances in the Treatment of Obstructive Sleep Apnea
    Smith, Yves K.
    Verrett, Ronald G.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (01): : 31 - 38
  • [26] The role of sleep position in obstructive sleep apnea syndrome
    Wietske Richard
    Dennis Kox
    Cindy den Herder
    Martin Laman
    Harm van Tinteren
    Nico de Vries
    European Archives of Oto-Rhino-Laryngology and Head & Neck, 2006, 263 : 946 - 950
  • [27] The Importance of Sleep Position in Obstructive Sleep Apnea Syndrome
    Koseoglu, Handan Inonu
    Kokturk, Oguz
    Cittci, Tansu Ulukavak
    Etikan, Ilker
    TURKISH THORACIC JOURNAL, 2014, 15 (01) : 23 - 26
  • [28] The role of sleep position in obstructive sleep apnea syndrome
    Richard, Wietske
    Kox, Dennis
    den Herder, Cindy
    Laman, Martin
    van Tinteren, Harm
    de Vries, Nico
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2006, 263 (10) : 946 - 950
  • [29] Evaluation of a Novel Ambulatory Device for Screening of Sleep Apnea
    Tiihonen, Pekka
    Hukkanen, Taina
    Tuomilehto, Henri
    Mervaala, Esa
    Toyras, Juha
    TELEMEDICINE JOURNAL AND E-HEALTH, 2009, 15 (03): : 283 - 289
  • [30] Body position and obstructive sleep apnea in eight to twelve month old infants
    Rathi, N.
    Tatakia, A.
    Weinstock, Y.
    Haque, S.
    Castriotta, R.
    Pereira, K.
    SLEEP, 2007, 30 : A91 - A92