Accuracy of low-cost alternative facial scanners: a prospective cohort study

被引:10
|
作者
Bartella, Alexander K. [1 ]
Laser, Josefine [1 ]
Kamal, Mohammad [2 ]
Krause, Matthias [1 ]
Neuhaus, Michael [1 ]
Pausch, Niels C. [1 ]
Sander, Anna K. [1 ]
Lethaus, Bernd [1 ]
Zimmerer, Rudiger [1 ]
机构
[1] Univ Leipzig, Dept Oral & Maxillofacial Surg, Liebigstr 12, D-04103 Leipzig, Germany
[2] Kuwait Univ, Fac Dent, Dept Surg Sci, Safat, Kuwait
来源
关键词
Face scan; Three-dimensional face scan; Photogrammetry; Smart device; iPhone; SYSTEM; MOBILE;
D O I
10.1007/s10006-022-01050-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction Three-dimensional facial scans have recently begun to play an increasingly important role in the peri-therapeutic management of oral and maxillofacial and head and neck surgery cases. Face scan images can be generated by optical facial scanners utilizing line-laser, stereophotography, or structured light modalities, as well as from volumetric data: for example, from cone beam computed tomography (CBCT). This study aimed to evaluate whether two low-cost procedures for the creation of three-dimensional face scan images were capable of producing sufficiently accurate data sets for clinical analysis. Materials and methods Fifty healthy volunteers were included in the study. Two test objects with defined dimensions (Lego bricks) were attached to the forehead and the left cheek of each volunteer. Facial anthropometric values (i.e., the distances between the medial canthi, the lateral canthi, the nasal alae, and the angles of the mouth) were first measured manually. Subsequently, face scans were performed with a smart device and manual photogrammetry and the values obtained were compared with the manually measured data sets. Results The anthropometric distances deviated, on average, 2.17 mm from the manual measurements (smart device scanning deviation 3.01 mm, photogrammetry deviation 1.34 mm), with seven out of eight deviations being statistically significant. For the Lego brick, from a total of 32 angles, 19 values demonstrated a significant difference from the original 90 degrees angles. The average deviation was 6.5 degrees (smart device scanning deviation 10.1 degrees, photogrammetry deviation 2.8 degrees). Conclusion Manual photogrammetry demonstrated greater accuracy when creating three-dimensional face scan images; however, smart devices are more user-friendly. Dental professionals should monitor camera and smart device technical improvements carefully when choosing and adequate technique for 3D scanning.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [41] Low-cost alternative for precious fuel cell catalysts
    不详
    PROFESSIONAL ENGINEERING, 2006, 19 (19) : 42 - 42
  • [42] An Alternative Low-Cost Solution for Tracking Laboratory Animals
    Kiziltan, Erhan
    Aydin, Leyla
    GAZI MEDICAL JOURNAL, 2020, 31 (02): : 137 - 142
  • [43] An Alternative Low-Cost Illumination Apparatus for Surgical Procedures
    Gorgulu, Tahsin
    Akcal, Arzu
    Yesiloglu, Nebil
    Tatlidede, Soner
    SURGICAL INNOVATION, 2015, 22 (02) : 201 - 202
  • [44] ALTERNATIVE MICROSCOPES BUILT USING LOW-COST MATERIALS
    Borges, Guilherme L. S.
    Borges, Pedro H. S.
    Cardoso, Cassia R.
    Cerqueira, Daniel A.
    QUIMICA NOVA, 2022, : 108 - 116
  • [45] LOW-COST ALTERNATIVE FOR REMEDIAL SAND CONTROL APPLICATION
    PEAVY, MA
    BUSH, ME
    PLUMMER, MA
    PEREZ, JI
    SPE DRILLING & COMPLETION, 1995, 10 (03) : 152 - 157
  • [46] HYPHa project: a low-cost alternative for integrated photonics
    Butt, Muhammad A.
    Kazmierczak, Andrzej
    Tyszkiewicz, Cuma
    Karasinski, Pawel
    Sroda, Edyta
    Olszewski, Jacek
    Pala, Piotr
    Martynkien, Tadeusz
    Hlushchenko, Daria
    Baraniecki, Tomasz
    Bachmatiuk, Alicja
    Jusza, Anna
    Guzik, Malgorzata
    Piramidowicz, Ryszard
    PHOTONICS LETTERS OF POLAND, 2022, 14 (02) : 25 - 27
  • [47] Alternative low-cost group housing for pregnant sows
    Connor, ML
    Fulawka, DL
    Onischuk, L
    LIVESTOCK ENVIRONMENT V, VOLS I AND II, 1997, : 393 - 400
  • [48] Evaluation of TagSeq, a reliable low-cost alternative for RNAseq
    Lohman, Brian K.
    Weber, Jesse N.
    Bolnick, Daniel I.
    MOLECULAR ECOLOGY RESOURCES, 2016, 16 (06) : 1315 - 1321
  • [49] PEER LANS OFFER A LOW-COST NETWORK ALTERNATIVE
    NANCE, B
    BYTE, 1991, 16 (12): : 303 - +
  • [50] HYDROLYZED LACTOSE - LOW-COST ALTERNATIVE TO CORN SYRUP
    MOORE, K
    FOOD PRODUCT DEVELOPMENT, 1978, 12 (04): : 72 - &