Accuracy of low-cost alternative facial scanners: a prospective cohort study

被引:10
|
作者
Bartella, Alexander K. [1 ]
Laser, Josefine [1 ]
Kamal, Mohammad [2 ]
Krause, Matthias [1 ]
Neuhaus, Michael [1 ]
Pausch, Niels C. [1 ]
Sander, Anna K. [1 ]
Lethaus, Bernd [1 ]
Zimmerer, Rudiger [1 ]
机构
[1] Univ Leipzig, Dept Oral & Maxillofacial Surg, Liebigstr 12, D-04103 Leipzig, Germany
[2] Kuwait Univ, Fac Dent, Dept Surg Sci, Safat, Kuwait
来源
关键词
Face scan; Three-dimensional face scan; Photogrammetry; Smart device; iPhone; SYSTEM; MOBILE;
D O I
10.1007/s10006-022-01050-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction Three-dimensional facial scans have recently begun to play an increasingly important role in the peri-therapeutic management of oral and maxillofacial and head and neck surgery cases. Face scan images can be generated by optical facial scanners utilizing line-laser, stereophotography, or structured light modalities, as well as from volumetric data: for example, from cone beam computed tomography (CBCT). This study aimed to evaluate whether two low-cost procedures for the creation of three-dimensional face scan images were capable of producing sufficiently accurate data sets for clinical analysis. Materials and methods Fifty healthy volunteers were included in the study. Two test objects with defined dimensions (Lego bricks) were attached to the forehead and the left cheek of each volunteer. Facial anthropometric values (i.e., the distances between the medial canthi, the lateral canthi, the nasal alae, and the angles of the mouth) were first measured manually. Subsequently, face scans were performed with a smart device and manual photogrammetry and the values obtained were compared with the manually measured data sets. Results The anthropometric distances deviated, on average, 2.17 mm from the manual measurements (smart device scanning deviation 3.01 mm, photogrammetry deviation 1.34 mm), with seven out of eight deviations being statistically significant. For the Lego brick, from a total of 32 angles, 19 values demonstrated a significant difference from the original 90 degrees angles. The average deviation was 6.5 degrees (smart device scanning deviation 10.1 degrees, photogrammetry deviation 2.8 degrees). Conclusion Manual photogrammetry demonstrated greater accuracy when creating three-dimensional face scan images; however, smart devices are more user-friendly. Dental professionals should monitor camera and smart device technical improvements carefully when choosing and adequate technique for 3D scanning.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [31] Perinatal outcome after icsi compared to a low-cost simplified ivf system in a selected population: A prospective cohort study
    Vertessen, V.
    Ombelet, W.
    Van der Auwera, I.
    Janssen, M.
    Onofre, J.
    Dhont, N.
    Campo, R.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2022, 270 : E88 - E88
  • [32] Reproducibility and Accuracy of Two Facial Scanners: A 3D In Vivo Study
    Pellitteri, Federica
    Calza, Marta
    Baldi, Giacomo
    De Maio, Matteo
    Lombardo, Luca
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [33] Enhancing the Accuracy of Low-Cost Inclinometers with Artificial Intelligence
    Lozano, Fidel
    Emadi, Seyyedbehrad
    Komarizadehasl, Seyedmilad
    Arteaga, Jesus Gonzalez
    Xia, Ye
    BUILDINGS, 2024, 14 (02)
  • [34] A comparison of accuracy using a GPS and a low-cost DGPS
    Matosevic, Mladen
    Salcic, Zoran
    Berber, Stevan
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (05) : 1677 - 1683
  • [35] PROTOTYPE TOOLING WITH LOW-COST, HIGH-ACCURACY
    HARRISON, PJ
    MODERN PLASTICS, 1980, 57 (08): : 64 - &
  • [36] High-accuracy GNSS Localization with Low-cost
    Musa, A. B. M.
    Baker, Chris
    Eftelioglu, Emre
    Chowdhury, Amber Roy
    30TH ACM SIGSPATIAL INTERNATIONAL CONFERENCE ON ADVANCES IN GEOGRAPHIC INFORMATION SYSTEMS, ACM SIGSPATIAL GIS 2022, 2022, : 678 - 681
  • [37] Low-cost Sub-meter Accuracy Anywhere
    Ray, Chuck
    PROCEEDINGS OF THE 19TH INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2006), 2006, : 212 - 216
  • [38] Optical Surgical Navigation: A Promising Low-cost Alternative
    Tsui, Darin
    Jo, Mitsuhiro
    Nguyen, Bryan
    Ahadian, Farshad
    Talke, Frank E.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [39] Ultrasound Elastography: Excitation Methods and Low-Cost Alternative
    Otesteanu, Corin F.
    PROCEEDINGS OF 2019 INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP 2019), 2019, : 103 - 107
  • [40] Low-Cost Alternative for Signal Generators in the Physics Laboratory
    Pathare, Shirish Rajan
    Raghavendra, M. K.
    Huli, Saurabhee
    PHYSICS TEACHER, 2017, 55 (05): : 301 - 305