Accuracy of low-cost alternative facial scanners: a prospective cohort study

被引:10
|
作者
Bartella, Alexander K. [1 ]
Laser, Josefine [1 ]
Kamal, Mohammad [2 ]
Krause, Matthias [1 ]
Neuhaus, Michael [1 ]
Pausch, Niels C. [1 ]
Sander, Anna K. [1 ]
Lethaus, Bernd [1 ]
Zimmerer, Rudiger [1 ]
机构
[1] Univ Leipzig, Dept Oral & Maxillofacial Surg, Liebigstr 12, D-04103 Leipzig, Germany
[2] Kuwait Univ, Fac Dent, Dept Surg Sci, Safat, Kuwait
来源
关键词
Face scan; Three-dimensional face scan; Photogrammetry; Smart device; iPhone; SYSTEM; MOBILE;
D O I
10.1007/s10006-022-01050-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction Three-dimensional facial scans have recently begun to play an increasingly important role in the peri-therapeutic management of oral and maxillofacial and head and neck surgery cases. Face scan images can be generated by optical facial scanners utilizing line-laser, stereophotography, or structured light modalities, as well as from volumetric data: for example, from cone beam computed tomography (CBCT). This study aimed to evaluate whether two low-cost procedures for the creation of three-dimensional face scan images were capable of producing sufficiently accurate data sets for clinical analysis. Materials and methods Fifty healthy volunteers were included in the study. Two test objects with defined dimensions (Lego bricks) were attached to the forehead and the left cheek of each volunteer. Facial anthropometric values (i.e., the distances between the medial canthi, the lateral canthi, the nasal alae, and the angles of the mouth) were first measured manually. Subsequently, face scans were performed with a smart device and manual photogrammetry and the values obtained were compared with the manually measured data sets. Results The anthropometric distances deviated, on average, 2.17 mm from the manual measurements (smart device scanning deviation 3.01 mm, photogrammetry deviation 1.34 mm), with seven out of eight deviations being statistically significant. For the Lego brick, from a total of 32 angles, 19 values demonstrated a significant difference from the original 90 degrees angles. The average deviation was 6.5 degrees (smart device scanning deviation 10.1 degrees, photogrammetry deviation 2.8 degrees). Conclusion Manual photogrammetry demonstrated greater accuracy when creating three-dimensional face scan images; however, smart devices are more user-friendly. Dental professionals should monitor camera and smart device technical improvements carefully when choosing and adequate technique for 3D scanning.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [1] Accuracy of low-cost alternative facial scanners: a prospective cohort study
    Alexander K. Bartella
    Josefine Laser
    Mohammad Kamal
    Matthias Krause
    Michael Neuhaus
    Niels C. Pausch
    Anna K. Sander
    Bernd Lethaus
    Rüdiger Zimmerer
    Oral and Maxillofacial Surgery, 2023, 27 : 33 - 41
  • [2] Beam space processing for low-cost scanners
    Ucar, FN
    Karaman, M
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1349 - 1352
  • [3] A LOW-COST LAN ALTERNATIVE
    MCMULLEN, J
    DATAMATION, 1990, 36 (15): : 59 - 61
  • [4] Low-Cost Sensors Accuracy Study and Enhancement Strategy
    Komarizadehasl, Seyedmilad
    Mobaraki, Behnam
    Ma, Haiying
    Lozano-Galant, Jose-Antonio
    Turmo, Jose
    APPLIED SCIENCES-BASEL, 2022, 12 (06):
  • [5] Optimising the accuracy of a low-cost photogrammetric motion study system
    Chong, AK
    PHOTOGRAMMETRIC RECORD, 2004, 19 (108): : 296 - 310
  • [6] DROPOFF RECYCLING AS A LOW-COST ALTERNATIVE
    GIES, G
    BIOCYCLE, 1995, 36 (03) : 30 - 33
  • [7] MICROFICHE - LOW-COST ALTERNATIVE TO CAI
    STILLWAY, LW
    FEDERATION PROCEEDINGS, 1978, 37 (06) : 1547 - 1547
  • [8] An alternative low-cost storage for kiwifruit
    Nanos, GD
    Kittas, C
    THIRD INTERNATIONAL SYMPOSIUM ON KIWIFRUIT, VOLS 1 AND 2, 1997, (444): : 625 - 628
  • [9] MINITACT GYROSCOPE - THE LOW-COST ALTERNATIVE
    CALIFANO, HT
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 1994, 9 (08) : 12 - 16
  • [10] Numerical study of low-cost alternative orbits around the Moon
    de Melo, CF
    Winter, OC
    Neto, EV
    SATELLITE DYNAMICS IN THE ERA OF INTERDISCIPLINARY SPACE GEODESY, 2005, 36 (03): : 552 - 560