Assessing quality assurance of multi-leaf collimator using the structural similarity index

被引:1
|
作者
Zhang, Hong [1 ]
Zhang, Baoshe [2 ]
Lasio, Giovanni [2 ]
Chen, Shifeng [2 ]
Tehrani, Joubin Nasehi [2 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Radiat Oncol, Nashville, TN USA
[2] Univ Maryland, Sch Med, Dept Radiat Oncol, 500 Upper Chesapeake Dr, Bel Air, MD 21014 USA
来源
关键词
Gamma index test; MLC; QA; SSI*; Structural Similarity Index; VMAT; GAMMA INDEX; MLC; IMRT; VERIFICATION; PERFORMANCE; DELIVERY; PLAN;
D O I
10.1002/acm2.14288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis study aims to evaluate the viability of utilizing the Structural Similarity Index (SSI*) as an innovative imaging metric for quality assurance (QA) of the multi-leaf collimator (MLC). Additionally, we compared the results obtained through SSI* with those derived from a conventional Gamma index test for three types of Varian machines (Trilogy, Truebeam, and Edge) over a 12-week period of MLC QA in our clinic.MethodTo assess sensitivity to MLC positioning errors, we designed a 1 cm slit on the reference MLC, subsequently shifted by 0.5-5 mm on the target MLC. For evaluating sensitivity to output error, we irradiated five 25 cm x 25 cm open fields on the portal image with varying Monitor Units (MUs) of 96-100. We compared SSI* and Gamma index tests using three linear accelerator (LINAC) machines: Varian Trilogy, Truebeam, and Edge, with MLC leaf widths of 1, 0.5, and 0.25 mm. Weekly QA included VMAT and static field modes, with Picket fence test images acquired. Mechanical uncertainties related to the LINAC head, electronic portal imaging device (EPID), and MLC during gantry rotation and leaf motion were monitored.ResultsThe Gamma index test started detecting the MLC shift at a threshold of 4 mm, whereas the SSI* metric showed sensitivity to shifts as small as 2 mm. Moreover, the Gamma index test identified dose changes at 95MUs, indicating a 5% dose difference based on the distance to agreement (DTA)/dose difference (DD) criteria of 1 mm/3%. In contrast, the SSI* metric alerted to dose differences starting from 97MUs, corresponding to a 3% dose difference. The Gamma index test passed all measurements conducted on each machine. However, the SSI* metric rejected all measurements from the Edge and Trilogy machines and two from the Truebeam.ConclusionsOur findings demonstrate that the SSI* exhibits greater sensitivity than the Gamma index test in detecting MLC positioning errors and dose changes between static and VMAT modes. The SSI* metric outperformed the Gamma index test regarding sensitivity across these parameters.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Characterization of a dynamic multi-leaf collimator for stereotactic radiotherapy applications
    Godwin, G. A.
    Simpson, J. B.
    Mugabe, K. V.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14): : 4643 - 4654
  • [42] Monte Carlo study of modulated electron delivery using a conventional multi-leaf collimator
    Xiong, W
    Li, J
    Price, R
    McNeeley, S
    Qin, L
    Ma, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1904 - 1904
  • [43] Impact of dose rates on the position accuracy of multi-leaf collimator
    Zhang, Yuhai
    Li, Yuemin
    Xia, Huosheng
    Wang, Jie
    RADIATION PHYSICS AND CHEMISTRY, 2012, 81 (12) : 1813 - 1816
  • [44] Characterization of an extendable multi-leaf collimator for clinical electron beams
    O'Shea, Tuathan P.
    Ge, Yuanyuan
    Foley, Mark J.
    Faddegon, Bruce A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23): : 7621 - 7638
  • [45] Improving the modelling of a multi-leaf collimator with tilted leaf sides used in radiotherapy
    Hussein, Mohammad
    Angerud, Agnes
    Saez, Jordi
    Bogaert, Evelien
    Lemire, Matthieu
    Barry, Miriam
    Patallo, Ileana Silvestre
    Shipley, David
    Clark, Catharine H.
    Hernandez, Victor
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [46] Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy
    Tanaka, Yuichi
    Hashimoto, Masatoshi
    Ishigami, Minoru
    Nakano, Masahiro
    Hasegawa, Tomoyuki
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [47] Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator
    Ge, Yuanyuan
    O'Brien, Ricky T.
    Shieh, Chun-Chien
    Booth, Jeremy T.
    Keall, Paul J.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [48] Modulated electron radiation therapy using a conventional multi-leaf collimator: A feasibility study
    Ding, M
    Li, J
    Price, R
    Paskalev, K
    McNeedey, SW
    Qin, L
    Xiong, W
    Ma, C
    MEDICAL PHYSICS, 2003, 30 (06) : 1447 - 1447
  • [49] Development of a novel delivery quality assurance system based on simultaneous verification of dose distribution and binary multi-leaf collimator opening in helical tomotherapy
    Yuichi Tanaka
    Masatoshi Hashimoto
    Minoru Ishigami
    Masahiro Nakano
    Tomoyuki Hasegawa
    Radiation Oncology, 18
  • [50] Dosimetric leaf gap and leaf trailing effect in a double-stacked multi-leaf collimator
    Hernandez, V.
    Saez, J.
    Angerud, A.
    Cayez, R.
    Khamphan, C.
    Nguyen, D.
    Vieillevigne, L.
    Feygelman, V.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S735 - S737