Assessing quality assurance of multi-leaf collimator using the structural similarity index

被引:1
|
作者
Zhang, Hong [1 ]
Zhang, Baoshe [2 ]
Lasio, Giovanni [2 ]
Chen, Shifeng [2 ]
Tehrani, Joubin Nasehi [2 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Radiat Oncol, Nashville, TN USA
[2] Univ Maryland, Sch Med, Dept Radiat Oncol, 500 Upper Chesapeake Dr, Bel Air, MD 21014 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 04期
关键词
Gamma index test; MLC; QA; SSI*; Structural Similarity Index; VMAT; GAMMA INDEX; MLC; IMRT; VERIFICATION; PERFORMANCE; DELIVERY; PLAN;
D O I
10.1002/acm2.14288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThis study aims to evaluate the viability of utilizing the Structural Similarity Index (SSI*) as an innovative imaging metric for quality assurance (QA) of the multi-leaf collimator (MLC). Additionally, we compared the results obtained through SSI* with those derived from a conventional Gamma index test for three types of Varian machines (Trilogy, Truebeam, and Edge) over a 12-week period of MLC QA in our clinic.MethodTo assess sensitivity to MLC positioning errors, we designed a 1 cm slit on the reference MLC, subsequently shifted by 0.5-5 mm on the target MLC. For evaluating sensitivity to output error, we irradiated five 25 cm x 25 cm open fields on the portal image with varying Monitor Units (MUs) of 96-100. We compared SSI* and Gamma index tests using three linear accelerator (LINAC) machines: Varian Trilogy, Truebeam, and Edge, with MLC leaf widths of 1, 0.5, and 0.25 mm. Weekly QA included VMAT and static field modes, with Picket fence test images acquired. Mechanical uncertainties related to the LINAC head, electronic portal imaging device (EPID), and MLC during gantry rotation and leaf motion were monitored.ResultsThe Gamma index test started detecting the MLC shift at a threshold of 4 mm, whereas the SSI* metric showed sensitivity to shifts as small as 2 mm. Moreover, the Gamma index test identified dose changes at 95MUs, indicating a 5% dose difference based on the distance to agreement (DTA)/dose difference (DD) criteria of 1 mm/3%. In contrast, the SSI* metric alerted to dose differences starting from 97MUs, corresponding to a 3% dose difference. The Gamma index test passed all measurements conducted on each machine. However, the SSI* metric rejected all measurements from the Edge and Trilogy machines and two from the Truebeam.ConclusionsOur findings demonstrate that the SSI* exhibits greater sensitivity than the Gamma index test in detecting MLC positioning errors and dose changes between static and VMAT modes. The SSI* metric outperformed the Gamma index test regarding sensitivity across these parameters.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Variation in Elekta iView electronic portal imager pixel scale factor with gantry angle, and impact on multi-leaf collimator quality assurance
    Goodall, Simon K.
    Norvill, Craig
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [32] Hazards of a Tungsten Multi-Leaf Collimator in Proton Beam Therapy
    Moskvin, V.
    Cheng, C.
    Das, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [33] Integration of the function generation synthesis into the design of a multi-leaf collimator
    Erkin Gezgin
    Mustafa Volkan Yazici
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [34] Clinical Feasibility of Multi-Leaf Collimator Based Dynamic Wedge
    Jeong, C.
    Kwak, J.
    Alm, S.
    Kim, J.
    Park, J.
    Yoon, S.
    Cho, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3372 - 3372
  • [35] Integration of the function generation synthesis into the design of a multi-leaf collimator
    Gezgin, Erkin
    Yazici, Mustafa Volkan
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (07)
  • [36] Multi-leaf collimator designs: the clinical significance of linear accelerators
    Cakir, Aydin
    Bilge, Hatice
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2012, 27 (01): : 46 - 54
  • [37] Preliminary inter-leaf transmission characterization of a neutron multi-leaf collimator
    Farr, J
    Yudelev, M
    Maughan, R
    Forman, J
    Blosser, E
    Horste, T
    MEDICAL PHYSICS, 2002, 29 (06) : 1327 - 1327
  • [38] Comparison of algorithms for static multi-leaf collimator field segmentation
    Ni, Dongdong
    Wu, Xu
    Chen, Jianqi
    Jing, Jia
    Liu, Caixia
    INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS SCIENCE, PTS 1 AND 2, 2011, 80-81 : 1091 - 1095
  • [39] An analytical approach for optimizing the leaf design of a multi-leaf collimator in a linear accelerator
    Topolnjak, R.
    van der Heide, U. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11): : 3007 - 3021
  • [40] Commissioning of the Elekta APEX dynamic micro multi-leaf collimator
    Ferrer, C.
    Plaza, R.
    Huertas, C.
    Aza, Z.
    Morera, R.
    Serrada, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1197 - S1197