Energetic analysis and performance improvement algorithm of transcritical CO2 heat pump water heater system

被引:10
|
作者
Liu, Xinxin [1 ,2 ]
Peng, Xu [1 ,2 ]
Yang, Yushen [1 ,2 ]
Qin, Xiang [1 ,2 ]
Wang, Dingbiao [1 ,2 ]
Wang, Guanghui [1 ,2 ]
Wang, Di [1 ,2 ]
机构
[1] Zhengzhou Univ, Sch Mech & Power Engn, Zhengzhou 450001, Peoples R China
[2] Minist Educ, Engn Res Ctr Energy Saving Technol & Equipment The, Zhengzhou 450001, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Heat pump water heater; Optimal discharge pressure; Improvement algorithm; CO2; OPTIMUM HIGH-PRESSURE; CARBON-DIOXIDE; OPTIMIZATION; CYCLE;
D O I
10.1016/j.applthermaleng.2023.121823
中图分类号
O414.1 [热力学];
学科分类号
摘要
Transcritical CO2 heat pump water heaters have been widely studied by researchers for its environmentally friendly nature and energy efficiency. To analyze the impact of various operating parameters on the heating performance of transcritical CO2 heat pump water heater systems, simulation models were developed and their accuracy was verified through experiments. Results indicated that the discharge pressure and CO2 temperature at the gas cooler outlet (Tgc,out) had a significant effect on the system performance, the coefficient of performance (COP) increased notably with higher evaporation temperatures, and the optimal discharge pressure varied depending on the evaporation temperature. The system equipped with intermediate heat exchanger demonstrated a lower optimal discharge pressure and a higher COP compared to the basic system. The inclusion of an intermediate heat exchanger in a system, the maximum COP is 2.99 % to 3.83 % higher than the basic system under the same conditions. It has been observed that the introduction of intermediate heat exchanger significantly improved the system performance when Tgc,out were 35 degrees C, 40 degrees C and 45 degrees C, corresponding to discharge pressures lower than 10.75 MPa, 11.167 MPa and 11.625 MPa. According to the research results, the optimal discharge pressure equation was fitted and an improved algorithm was proposed. Compared to the experimental values, the improved algorithm exhibits a maximum error of 8.81 % and 7.55 % for determining the optimal discharge pressure and temperature, and the improved algorithm is effective in engineering applications. Consequently, the simulation data holds great importance in guiding the design of transcritical CO2 heat pump water heater systems.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Reanalysis of characteristics of CO2 transcritical heat pump system
    CO2跨临界热泵系统特性再分析
    Li, Minxia (tjmxli@tju.edu.cn), 1600, Materials China (39): : 1252 - 1258
  • [42] Modeling and simulation of the transcritical CO2 heat pump system
    Lin, Kai-Hsiang
    Kuo, Cheng-Shu
    Hsieh, Wen-Der
    Wang, Chi-Chuan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08): : 2048 - 2064
  • [43] EXPERIMENTAL AND SIMULATION STUDY OF TRANSCRITICAL CO2 WATER-WATER HEAT PUMP SYSTEM
    Yang, Junlan
    Zhang, Xin
    Du, Yufan
    Han, Yifei
    Wang, Linxiu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (08): : 265 - 272
  • [44] Experimental Investigation on Transcritical CO2 Heat Pump System
    Liu, Yingfu
    Zhao, Mingxing
    Jin, Guangya
    2016 INTERNATIONAL CONFERENCE ON ARCHITECTURE AND CIVIL ENGINEERING (ICACE 2016), 2016, : 605 - 609
  • [45] SYSTEM OPTIMIZATION OF CO2 HEAT PUMP WATER HEATER BASED ON ECONOMY
    Zhang, F. Z.
    Jiang, P. X.
    Zhu, Y. H.
    Sun, S. S.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 593 - 599
  • [46] CO2 Heat Pump Water Heater: System Design and Experimental Study
    Liu, Yefeng
    Zhuo, Zhiyang
    Zhang, Feng
    Bao, Tuanwei
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 131 - 142
  • [47] Energetic, economic and environmental analysis of air source transcritical CO2 heat pump system for residential heating in China
    Liu, Shengchun
    Li, Zheng
    Dai, Baomin
    Zhong, Zhifeng
    Li, Hailong
    Song, Mengjie
    Sun, Zhili
    APPLIED THERMAL ENGINEERING, 2019, 148 : 1425 - 1439
  • [48] Detailed Theoretical Characterization of a Transcritical CO2 Direct Expansion Ground Source Heat Pump Water Heater
    Eslami-Nejad, Parham
    Badache, Messaoud
    Bastani, Arash
    Aidoun, Zine
    ENERGIES, 2018, 11 (02)
  • [49] Analysis of CO2 Transcritical Cycle Heat Pump Dryers
    Li, Minxia
    Ma, Yitai
    Gong, Wenjin
    Su, Weicheng
    DRYING TECHNOLOGY, 2009, 27 (04) : 548 - 554
  • [50] Experimental and techno-economic analysis of transcritical CO2 heat pump water heater with fin-and-tube and microchannel heat exchanger
    Wang, Yikai
    Zong, Shuo
    Song, Yulong
    Cao, Feng
    He, Yaling
    Gao, Qiang
    APPLIED THERMAL ENGINEERING, 2021, 199 (199)