Energetic analysis and performance improvement algorithm of transcritical CO2 heat pump water heater system

被引:10
|
作者
Liu, Xinxin [1 ,2 ]
Peng, Xu [1 ,2 ]
Yang, Yushen [1 ,2 ]
Qin, Xiang [1 ,2 ]
Wang, Dingbiao [1 ,2 ]
Wang, Guanghui [1 ,2 ]
Wang, Di [1 ,2 ]
机构
[1] Zhengzhou Univ, Sch Mech & Power Engn, Zhengzhou 450001, Peoples R China
[2] Minist Educ, Engn Res Ctr Energy Saving Technol & Equipment The, Zhengzhou 450001, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Heat pump water heater; Optimal discharge pressure; Improvement algorithm; CO2; OPTIMUM HIGH-PRESSURE; CARBON-DIOXIDE; OPTIMIZATION; CYCLE;
D O I
10.1016/j.applthermaleng.2023.121823
中图分类号
O414.1 [热力学];
学科分类号
摘要
Transcritical CO2 heat pump water heaters have been widely studied by researchers for its environmentally friendly nature and energy efficiency. To analyze the impact of various operating parameters on the heating performance of transcritical CO2 heat pump water heater systems, simulation models were developed and their accuracy was verified through experiments. Results indicated that the discharge pressure and CO2 temperature at the gas cooler outlet (Tgc,out) had a significant effect on the system performance, the coefficient of performance (COP) increased notably with higher evaporation temperatures, and the optimal discharge pressure varied depending on the evaporation temperature. The system equipped with intermediate heat exchanger demonstrated a lower optimal discharge pressure and a higher COP compared to the basic system. The inclusion of an intermediate heat exchanger in a system, the maximum COP is 2.99 % to 3.83 % higher than the basic system under the same conditions. It has been observed that the introduction of intermediate heat exchanger significantly improved the system performance when Tgc,out were 35 degrees C, 40 degrees C and 45 degrees C, corresponding to discharge pressures lower than 10.75 MPa, 11.167 MPa and 11.625 MPa. According to the research results, the optimal discharge pressure equation was fitted and an improved algorithm was proposed. Compared to the experimental values, the improved algorithm exhibits a maximum error of 8.81 % and 7.55 % for determining the optimal discharge pressure and temperature, and the improved algorithm is effective in engineering applications. Consequently, the simulation data holds great importance in guiding the design of transcritical CO2 heat pump water heater systems.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater
    Zhang, Ze
    Dong, Xiaojun
    Ren, Zheng
    Lai, Tianwei
    Hou, Yu
    ENERGIES, 2017, 10 (10):
  • [12] Experimental investigation on the influence of internal heat exchanger in a transcritical CO2 heat pump water heater
    Cao, Feng
    Ye, Zuliang
    Wang, Yikai
    APPLIED THERMAL ENGINEERING, 2020, 168 (168)
  • [13] Experimental investigation of the optimal heat rejection pressure for a transcritical CO2 heat pump water heater
    Qi, Peng-Cheng
    He, Ya-Ling
    Wang, Xiao-Lin
    Meng, Xiang-Zhao
    APPLIED THERMAL ENGINEERING, 2013, 56 (1-2) : 120 - 125
  • [14] Experimental investigation of the extreme seeking control on a transcritical CO2 heat pump water heater
    Cui, Ce
    Zong, Shuo
    Song, Yulong
    Yin, Xiang
    Cao, Feng
    International Journal of Refrigeration, 2022, 133 : 111 - 122
  • [15] Experimental study and optimal control strategy of a transcritical CO2 heat pump water heater
    Ye, Zuliang
    Wang, Yikai
    Cao, Feng
    INTERNATIONAL CONFERENCE ON COMPRESSORS AND THEIR SYSTEMS 2019, 2019, 604
  • [16] Performance Analysis of Coupled System of CO2 Transcritical Heat Pump and Rankine Cycle
    Wang, Hongli
    Tian, Jingrui
    Ma, Yitai
    Hou, Xiujuan
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 1860 - +
  • [17] Comprehensive evaluation of the transcritical CO2 ejector-expansion heat pump water heater
    Wang, Yikai
    Yin, Yonggao
    Cao, Feng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 276 - 289
  • [18] Analysis of performance of CO2 transcritical heat pump system with mechanical subcooling and ejector
    Dong L.
    Li M.
    Yao L.
    Ma Y.
    Zhan H.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (10): : 5431 - 5440
  • [19] Design and simulation of residential CO2 transcritical heat pump water heater in central China
    Zhang, X. P.
    Fan, X. W.
    Wang, F. K.
    Shen, H. G.
    Zheng, H. F.
    Duan, H. L.
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 4, 2008, : 775 - 779
  • [20] Experimental investigation of the extreme seeking control on a transcritical CO2 heat pump water heater
    Cui, Ce
    Zong, Shuo
    Song, Yulong
    Yin, Xiang
    Cao, Feng
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 : 111 - 122