Energetic analysis and performance improvement algorithm of transcritical CO2 heat pump water heater system

被引:10
|
作者
Liu, Xinxin [1 ,2 ]
Peng, Xu [1 ,2 ]
Yang, Yushen [1 ,2 ]
Qin, Xiang [1 ,2 ]
Wang, Dingbiao [1 ,2 ]
Wang, Guanghui [1 ,2 ]
Wang, Di [1 ,2 ]
机构
[1] Zhengzhou Univ, Sch Mech & Power Engn, Zhengzhou 450001, Peoples R China
[2] Minist Educ, Engn Res Ctr Energy Saving Technol & Equipment The, Zhengzhou 450001, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Heat pump water heater; Optimal discharge pressure; Improvement algorithm; CO2; OPTIMUM HIGH-PRESSURE; CARBON-DIOXIDE; OPTIMIZATION; CYCLE;
D O I
10.1016/j.applthermaleng.2023.121823
中图分类号
O414.1 [热力学];
学科分类号
摘要
Transcritical CO2 heat pump water heaters have been widely studied by researchers for its environmentally friendly nature and energy efficiency. To analyze the impact of various operating parameters on the heating performance of transcritical CO2 heat pump water heater systems, simulation models were developed and their accuracy was verified through experiments. Results indicated that the discharge pressure and CO2 temperature at the gas cooler outlet (Tgc,out) had a significant effect on the system performance, the coefficient of performance (COP) increased notably with higher evaporation temperatures, and the optimal discharge pressure varied depending on the evaporation temperature. The system equipped with intermediate heat exchanger demonstrated a lower optimal discharge pressure and a higher COP compared to the basic system. The inclusion of an intermediate heat exchanger in a system, the maximum COP is 2.99 % to 3.83 % higher than the basic system under the same conditions. It has been observed that the introduction of intermediate heat exchanger significantly improved the system performance when Tgc,out were 35 degrees C, 40 degrees C and 45 degrees C, corresponding to discharge pressures lower than 10.75 MPa, 11.167 MPa and 11.625 MPa. According to the research results, the optimal discharge pressure equation was fitted and an improved algorithm was proposed. Compared to the experimental values, the improved algorithm exhibits a maximum error of 8.81 % and 7.55 % for determining the optimal discharge pressure and temperature, and the improved algorithm is effective in engineering applications. Consequently, the simulation data holds great importance in guiding the design of transcritical CO2 heat pump water heater systems.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Thermodynamic performance improvement and economic analysis of CO2 transcritical heat pump system
    Yao L.
    Li M.
    Ma Y.
    Liu X.
    Wang Q.
    Wang P.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2021, 40 (05): : 2422 - 2430
  • [2] Study of CO2 transcritical cycle heat pump water heater
    Li, Minxia
    Gong, Wenjin
    Ma, Yitai
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1544 - 1550
  • [3] The Influence of Internal Heat Exchanger on the Performance of Transcritical CO2 Water Source Heat Pump Water Heater
    Feng, Fan
    Zhang, Ze
    Liu, Xiufang
    Liu, Changhai
    Hou, Yu
    ENERGIES, 2020, 13 (07)
  • [4] Experimental investigation on the performance of transcritical CO2 ejector-expansion heat pump water heater system
    Zhu, Yinhai
    Huang, Yulei
    Li, Conghui
    Zhang, Fuzhen
    Jiang, Pei-Xue
    ENERGY CONVERSION AND MANAGEMENT, 2018, 167 : 147 - 155
  • [5] Experimental study on two types of transcritical CO2 heat pump water heater system
    Chen, Qi
    Tong, Yang
    Li, Mao
    Zhu, Zhijiang
    Tang, Liming
    Chen, Guangming
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2013, 34 (11): : 1903 - 1909
  • [6] Optimization of Refrigerant Charge in Transcritical CO2 Heat Pump Water Heater
    He, Yu-Jia
    Liang, Xing-Yu
    Cheng, Jia-Hao
    Zhang, Chun-Lu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (04): : 824 - 827
  • [7] Performance Analysis of CO2 Heat Pump Water Heater with an Ejector
    Ju Cheng-cheng
    Yang Jun-lan
    Qu Hong-wei
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [8] Effects of refrigerant charge on performances of transcritical CO2 heat pump water heater
    Jin D.
    Koyama S.
    Xue J.
    Takata N.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2010, 45 (05): : 680 - 684
  • [9] The Heating Performance of a CO2 Heat Pump Water Heater
    Baek, Changhyun
    Lee, Eungchan
    Kang, Hoon
    Kim, Yongchan
    Cho, Honghyun
    Cho, Sungwook
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 258 - 263
  • [10] Performance optimization of CO2 heat pump water heater
    Nawaz, Kashif
    Shen, Bo
    Elatar, Ahmed
    Baxter, Van
    Abdelaziz, Omar
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2018, 85 : 213 - 228