A 4.5 μW Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System

被引:1
|
作者
Rezaeiyan, Yasser [1 ]
Koolivand, Yarallah [2 ]
Zamani, Milad [1 ]
Shoaei, Omid [3 ]
Akbari, Meysam [4 ]
Moradi, Farshad [1 ]
Tang, Kea-Tiong [5 ]
机构
[1] Aarhus Univ, Dept Engn, Integrated Circuits & Elect Lab, DK-8200 Aarhus, Denmark
[2] KN Toosi Univ Technol, Elect Engn, Tehran 1541849611, Iran
[3] Univ Tehran, Sch Elect & Comp Engn, Biointegrated Syst Lab, Tehran 1439957131, Iran
[4] Univ Kurdistan, Dept Elect Engn, Sanandaj 6617715175, Iran
[5] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu 30013, Taiwan
关键词
Monitoring; Modulation; Electrocardiography; Frequency modulation; Wireless communication; Transmitters; Receivers; Analog front-end (AFE); electrocardiography (ECG); intra-cardiac signal; implantable systems; wireless telemetry; FRONT-END; CHOPPER AMPLIFIER; DYNAMIC-RANGE; MODE; SOC; EXTRACTION; TOLERANT; SENSOR; ADC;
D O I
10.1109/TBCAS.2023.3294560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article presents a chip designed for wireless intra-cardiac monitoring systems. The design consists of a three-channel analog front-end, a pulse-width modulator featuring output-frequency offset and temperature calibration, and inductive data telemetry. By employing a resistance boosting technique in the instrumentation amplifier feedback, the pseudo-resistor exhibits lower non-linearity, leading to a total harmonic distortion of below 0.1%. Furthermore, the boosting technique enhances the feedback resistance, leading to a reduction in the size of the feedback capacitor and, consequently, the overall size. To make the modulator's output frequency resilient to temperature and process changes, coarse and fine-tuning algorithms are used. The front-end channel is capable of extracting the intra-cardiac signal with an effective number of bits of 8.9, while exhibiting an input-referred noise of less than 2.7 mu V-rms , and consuming 200 nW per channel. The front-end output is encoded by an ASK-PWM modulator, which drives an on-chip transmitter at 13.56 MHz. The proposed System-on-Chip (SoC) is fabricated in a 0.18 mu m standard CMOS technology and consumes 4.5 mu W while occupying 1.125 mm(2) .
引用
收藏
页码:1097 / 1110
页数:14
相关论文
共 50 条
  • [31] A W-band measurement system for wireless channel modeling
    Aryanfar, F
    Sarabandi, K
    5TH INTERNATIONAL SYMPOSIUM ON WIRELESS PERSONAL MULTIMEDIA COMMUNICATIONS, VOLS 1-3, PROCEEDINGS, 2002, : 577 - 580
  • [32] An Ultrasound Matrix Transducer for High-Frame-Rate 3-D Intra-cardiac Echocardiography
    dos Santos, Djalma Simoes
    Ossenkoppele, Boudewine
    Hopf, Yannick M.
    Soozande, Mehdi
    Noothout, Emile
    Vos, Hendrik J.
    Bosch, Johan G.
    Pertijs, Michiel A. P.
    Verweij, Martin D.
    de Jong, Nico
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (02): : 285 - 294
  • [33] 3-channel double relaxation oscillation SQUID magnetometer system with simple readout electronics
    Lee, Y.H.
    Kim, J.M.
    Kwon, H.C.
    Park, Y.K.
    Park, J.C.
    van Duuren, M.J.
    Adelerhof, D.J.
    Flokstra, J.
    Rogalla, H.
    IEEE Transactions on Applied Superconductivity, 1995, 5 (2 pt 3): : 2156 - 2159
  • [34] A MICROCOMPUTER SYSTEM FOR PROCESSING DATA FROM A 3-CHANNEL ATOMIC-ABSORPTION SPECTROMETER
    ADAMS, MJ
    MITCHELL, MC
    EWEN, GJ
    ANALYTICA CHIMICA ACTA, 1983, 149 (MAY) : 101 - 106
  • [35] Sewing needle: a rare cause of intra-cardiac foreign body in a 3-year-old child
    Choudhary, Sandeep
    Venkateshacharya, Suresh Pujar
    Reddy, Chinnaswamy
    CARDIOLOGY IN THE YOUNG, 2016, 26 (07) : 1425 - 1427
  • [36] 3-CHANNEL DOUBLE RELAXATION OSCILLATION SQUID MAGNETOMETER SYSTEM WITH SIMPLE READOUT ELECTRONICS
    LEE, YH
    KIM, JM
    KWON, HC
    PARK, YK
    PARK, JC
    VANDUUREN, MJ
    ADELERHOF, DJ
    FLOKSTRA, J
    ROGALLA, H
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 2156 - 2159
  • [37] A Portable and Wireless Multi-Channel Acquisition System for Physiological Signal Measurements
    Liu, Shing-Hong
    Wang, Jia-Jung
    Tan, Tan-Hsu
    SENSORS, 2019, 19 (23)
  • [38] Wireless Multi-channel Physiological Data Acquisition System In Intelligent Classroom
    Gui, Lin
    Zhang, Wei
    Fing, Shenqi
    Zhang, Yongkui
    MBE 2008: ASIA -PACIFIC CONFERENCE ON MIND BRAIN AND EDUCATION, 2008, : 337 - +
  • [39] Design of a Wireless Multi-channel Surface EMG Signal Acquisition System
    Zhou, Rong
    Luo, Qiang
    Feng, Xiaorong
    Li, Chenglong
    PROCEEDINGS OF 2017 3RD IEEE INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATIONS (ICCC), 2017, : 279 - 283
  • [40] A Wireless 8-Channel ECG Biopotential Acquisition System for Dry Electrodes
    Pu, Xiaofei
    Wan, Lei
    Sheng, Yun
    Chiang, Patrick
    Qin, Yajie
    Hong, Zhiliang
    PROCEEDINGS OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON RADIO-FREQUENCY INTEGRATION TECHNOLOGY (RFIT), 2012, : 140 - 142