A Wireless 8-Channel ECG Biopotential Acquisition System for Dry Electrodes

被引:0
|
作者
Pu, Xiaofei [1 ]
Wan, Lei [1 ]
Sheng, Yun [2 ]
Chiang, Patrick [1 ,3 ]
Qin, Yajie [1 ]
Hong, Zhiliang [1 ]
机构
[1] Fudan Univ, State Key Lab ASIC & Syst, Shanghai 201203, Peoples R China
[2] Nanosense Corp, Shanghai 201203, Peoples R China
[3] Oregon State Univ, Corvallis, OR 97331 USA
关键词
ECG dry metal electrode; wireless; chopper modulation; instrumentation amplifier; CIRCUIT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A wireless 8-channel biopotential acquisition system for capturing electrocardiogram (ECG) using dry electrodes is presented. The ECG system consists of copper electrodes, a micropowered 8-channel custom ASIC, and an off-the-shelf microprocessor and bluetooth radio. Each analog channel of the custom ECG front-end is composed of a chopper-modulated instrumentation amplifier (CMIA) with chopping spike filter (CSF), a programmable gain amplifier (PGA), and a output buffer. Implemented in standard a 0.35 gm CMOS technology, the ECG front-end consumes 101 mu A from a 2.7 V supply, occupying 5 mm(2) of chip area. Measurement results show an input impedance of 1 G Omega, an input-referred noise of 0.97 mu Vrms (0.5 similar to 100 Hz), and a CM of 114 dB. Finally, a complete wireless 8-channel ECG monitoring system incorporating this analog front-end is demonstrated, showing successful recordings of a capture ECG waveform using a smart phone.
引用
收藏
页码:140 / 142
页数:3
相关论文
共 50 条
  • [1] Low noise multi-channel biopotential wireless data acquisition system for dry electrodes
    Pandian, P. S.
    Whitchurch, Ashwin K.
    Abraham, Jose K.
    Baskey, Himanshu Bhusan
    Radhakrishnan, J. K.
    Varadan, Vijay K.
    Padaki, V. C.
    Rao, K. U. Bhasker
    Harbaugh, R. E.
    NANOSENSORS AND MICROSENSORS FOR BIO-SYSTEMS 2008, 2008, 6931
  • [2] A Dual Loop 8-Channel ECG Recording System with Fast Settling Mode
    Zeng, Lei
    Heng, Chun Huat
    ESSCIRC 2018 - IEEE 44TH EUROPEAN SOLID STATE CIRCUITS CONFERENCE (ESSCIRC), 2018, : 218 - 221
  • [3] Validation of a Wireless and Portable EEG Acquisition System with Dry Electrodes
    Canadas, G. E.
    Dell'Aquila, C. R.
    Garces, A.
    Laciar, E.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 833 - 837
  • [4] Wireless biopotential acquisition system for portable healthcare monitoring
    Wang W.-S.
    Huang H.-Y.
    Wu Z.-C.
    Chen S.-C.
    Wang W.-F.
    Wu C.-F.
    Luo C.-H.
    Journal of Medical Engineering and Technology, 2011, 35 (05): : 254 - 261
  • [5] In vivo characterization of a versatile 8-channel digital biopotential recording system with sub-μVRMS input noise
    Cota, Oscar F.
    Plachta, Dennis
    Stieglitz, Thomas
    Kundumattathil, Sarath
    Manoli, Yiannos
    Kuhl, Matthias
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 6311 - 6314
  • [6] EXTRACOCHLEAR 8-CHANNEL ELECTRODE SYSTEM
    BANFAI, P
    HORTMANN, G
    KUBIK, S
    KARCZAG, A
    LUERS, P
    SURTH, W
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1985, 99 (06): : 549 - 553
  • [7] PROGRAMMABLE 8-CHANNEL BIOTELEMETRY SYSTEM
    NEUKOMM, PA
    FRIEDRICH, R
    BIOTELEMETRY AND PATIENT MONITORING, 1980, 7 (01) : 24 - 24
  • [8] 8-channel acquisition system for time-correlated single-photon counting
    Antonioli, S.
    Miari, L.
    Cuccato, A.
    Crotti, M.
    Rech, I.
    Ghioni, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (06):
  • [9] A Modular and Wireless ExG Signal Acquisition System with a Dense Array of Dry Electrodes
    Ghoshdastider, U.
    Lange, C.
    Viga, R.
    Grabmaier, A.
    2012 IEEE SENSORS PROCEEDINGS, 2012, : 1212 - 1215
  • [10] Design and simulation of an 8-channel CWDM System
    Shaabany, Afshin
    2010 INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT (CCCM2010), VOL II, 2010, : 553 - 555