A 4.5 μW Miniaturized 3-Channel Wireless Intra-Cardiac Acquisition System

被引:1
|
作者
Rezaeiyan, Yasser [1 ]
Koolivand, Yarallah [2 ]
Zamani, Milad [1 ]
Shoaei, Omid [3 ]
Akbari, Meysam [4 ]
Moradi, Farshad [1 ]
Tang, Kea-Tiong [5 ]
机构
[1] Aarhus Univ, Dept Engn, Integrated Circuits & Elect Lab, DK-8200 Aarhus, Denmark
[2] KN Toosi Univ Technol, Elect Engn, Tehran 1541849611, Iran
[3] Univ Tehran, Sch Elect & Comp Engn, Biointegrated Syst Lab, Tehran 1439957131, Iran
[4] Univ Kurdistan, Dept Elect Engn, Sanandaj 6617715175, Iran
[5] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu 30013, Taiwan
关键词
Monitoring; Modulation; Electrocardiography; Frequency modulation; Wireless communication; Transmitters; Receivers; Analog front-end (AFE); electrocardiography (ECG); intra-cardiac signal; implantable systems; wireless telemetry; FRONT-END; CHOPPER AMPLIFIER; DYNAMIC-RANGE; MODE; SOC; EXTRACTION; TOLERANT; SENSOR; ADC;
D O I
10.1109/TBCAS.2023.3294560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This article presents a chip designed for wireless intra-cardiac monitoring systems. The design consists of a three-channel analog front-end, a pulse-width modulator featuring output-frequency offset and temperature calibration, and inductive data telemetry. By employing a resistance boosting technique in the instrumentation amplifier feedback, the pseudo-resistor exhibits lower non-linearity, leading to a total harmonic distortion of below 0.1%. Furthermore, the boosting technique enhances the feedback resistance, leading to a reduction in the size of the feedback capacitor and, consequently, the overall size. To make the modulator's output frequency resilient to temperature and process changes, coarse and fine-tuning algorithms are used. The front-end channel is capable of extracting the intra-cardiac signal with an effective number of bits of 8.9, while exhibiting an input-referred noise of less than 2.7 mu V-rms , and consuming 200 nW per channel. The front-end output is encoded by an ASK-PWM modulator, which drives an on-chip transmitter at 13.56 MHz. The proposed System-on-Chip (SoC) is fabricated in a 0.18 mu m standard CMOS technology and consumes 4.5 mu W while occupying 1.125 mm(2) .
引用
收藏
页码:1097 / 1110
页数:14
相关论文
共 50 条
  • [21] Miniaturized 3-Lead Electrocardiogram System Based on Einthoven Triangle for Wireless Cardiac Care Monitoring
    Rahman, Md. Ataur
    Robel, Md. Rokunuzzaman
    Patil, Basanagouda
    Saleem, Syed Haider
    Borkhatariya, Sagar Sanjay
    Bhaskaran, Madhu
    Sriram, Sharath
    ADVANCED INTELLIGENT SYSTEMS, 2024, 6 (01)
  • [22] COMPARISON OF A PROGRAMMABLE 3-CHANNEL COMPRESSION HEARING SYSTEM WITH SINGLE-CHANNEL AGC INSTRUMENTS
    KIESSLING, J
    STEFFENS, T
    SCANDINAVIAN AUDIOLOGY, 1993, 22 : 65 - 74
  • [23] 3-channel acousto-optic modulator for laser projection display system
    Kim, YH
    Park, JH
    Cha, SN
    Hwang, YM
    CURRENT DEVELOPMENTS IN OPTICAL DESIGN AND ENGINEERING VII, 1998, 3429 : 204 - 212
  • [24] Intra-cardiac 2D US to 3D CT image registration
    Huang, Xishi
    Hill, Nicholas A.
    Ren, Jing
    Guiraudon, Gerard
    Peters, Terry M.
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [26] A compact and miniaturized implantable antenna for ISM band in wireless cardiac pacemaker system
    Feng, Yang
    Li, Zhaonan
    Qi, Lin
    Shen, Wanting
    Li, Gaosheng
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [27] Fusion of 3D Ultrasound and Cardiac-MRI Shows Motional Intra-Cardiac Blood Flow In the Whole Cardiac Cycle
    Sughimoto, Koichi
    Shimamura, Yoshiaki
    Liu, Hao
    Tsubota, Ken'ichi
    Miyaji, Kagami
    Yoshii, Takeshi
    Torii, Shinzo
    Kitamura, Tadashi
    Hirata, Mitsuhiro
    Mishima, Toshiaki
    Horai, Tetsuya
    Haneishi, Hideaki
    CARDIOLOGY, 2016, 134 (02) : 224 - 225
  • [28] A compact and miniaturized implantable antenna for ISM band in wireless cardiac pacemaker system
    Yang Feng
    Zhaonan Li
    Lin Qi
    Wanting Shen
    Gaosheng Li
    Scientific Reports, 12
  • [29] 3-CHANNEL TELEMETRY SYSTEM FOR MONITORING ECG CARDIAC-OUTPUT, RATE OF RESPIRATION AND BASAL TRANS-THORACIC ADMITTANCE
    BUKHARI, ARS
    YAMAKOSHI, K
    TOYOSHIMA, T
    TOGAWA, T
    ITO, H
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (04) : 426 - 432