Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms

被引:5
|
作者
Greffier, Joel [1 ]
Van Ngoc Ty, Claire [2 ]
Fitton, Isabelle [2 ]
Frandon, Julien [1 ]
Beregi, Jean-Paul [1 ]
Dabli, Djamel [1 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, Dept Med Imaging, IMAGINE UR UM 103, F-30029 Nimes, France
[2] Univ Paris, Hop Europeen Georges Pompidou, AP HP, Dept Radiol, F-75015 Paris, France
关键词
dual-energy; multidetector computed tomography; task-based image quality assessment; split-filter; RECONSTRUCTION;
D O I
10.3390/diagnostics13193039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the quality of low-energy virtual monoenergetic images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the phantom diameter. Three sections of the Mercury Phantom 4.0 were scanned on two generations of split-filter CTs (SFCT-1st and SFCT-2nd) and on one Dual-source CT (DSCT). The noise power spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were assessed on VMIs from 40 to 70 keV. The highest noise magnitude values were found with SFCT-1st and noise magnitude was higher with DSCT than with SFCT-2nd for 26 cm (10.2% +/- 1.3%) and 31 cm (7.0% +/- 2.5%), and the opposite for 36 cm (-4.2% +/- 2.5%). The highest average NPS spatial frequencies and TTF values at 50% (f50) values were found with DSCT. For all energy levels, the f50 values were higher with SFCT-2nd than SFCT-1st for 26 cm (3.2% +/- 0.4%) and the opposite for 31 cm (-6.9% +/- 0.5%) and 36 cm (-5.6% +/- 0.7%). The lowest d' values were found with SFCT-1st. For all energy levels, the d' values were lower with DSCT than with SFCT-2nd for 26 cm (-6.2% +/- 0.7%), similar for 31 cm (-0.3% +/- 1.9%) and higher for 36 cm (5.4% +/- 2.7%). In conclusion, compared to SFCT-1st, SFCT-2nd exhibited a lower noise magnitude and higher detectability values. Compared with DSCT, SFCT-2nd had a lower noise magnitude and higher detectability for the 26 cm, but the opposite was true for the 36 cm.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Determination of the optimal range for virtual monoenergetic images in dual-energy CT based on physical quality parameters
    Fernandez-Velilla Cepria, Enric
    Angel Gonzalez-Ballester, Miguel
    Quera Jordana, Jaume
    Pera, Oscar
    Sanz Latiesas, Xavier
    Foro Arnalot, Palmira
    Membrive Conejo, Ismael
    Rodriguez de Dios, Nuria
    Reig Castillejo, Anna
    Algara Lopez, Manuel
    MEDICAL PHYSICS, 2021, 48 (09) : 5085 - 5095
  • [22] Proton stopping power prediction based on dual-energy CT-generated virtual monoenergetic images
    Nasmark, Torbjorn
    Andersson, Jonas
    MEDICAL PHYSICS, 2021, 48 (09) : 5232 - 5243
  • [23] Accuracy of Dual-Energy CT Virtual Unenhanced and Material-Specific Images: A Phantom Study
    Li, Baojun
    Pomerleau, Mark
    Gupta, Avneesh
    Soto, Jorge A.
    Anderson, Stephan W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (05) : 1146 - 1154
  • [24] Dual-Energy CT and Virtual Low-Energy Reconstruction for 3D Visualization of Thin Bone
    Abramson, Zachary
    Burton, Christiane
    Goode, Chris
    Sheyn, Anthony
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 376 - 376
  • [25] Deep-learning-based direct synthesis of low-energy virtual monoenergetic images with multi-energy CT
    Gong, Hao
    Marsh, Jeffrey F.
    D'Souza, Karen N.
    Huber, Nathan R.
    Rajendran, Kishore
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (05)
  • [26] Dual-energy CT with virtual monoenergetic images to improve the visualization of pancreatic supplying arteries: the normal anatomy and variations
    Hong-wei Liang
    Yang Zhou
    Zhi-wei Zhang
    Gao-wu Yan
    Si-lin Du
    Xiao-hui Zhang
    Xin-you Li
    Fa-jin Lv
    Qiao Zheng
    Yong-mei Li
    Insights into Imaging, 13
  • [27] Radiomics based on dual-energy CT virtual monoenergetic images to identify symptomatic carotid plaques: a multicenter study
    Hu, Weiming
    Lin, Guihan
    Chen, Weiyue
    Wu, Jianhua
    Zhao, Ting
    Xu, Lei
    Qian, Xusheng
    Shen, Lin
    Yan, Zhihan
    Chen, Minjiang
    Xia, Shuiwei
    Lu, Chenying
    Yang, Jing
    Xu, Min
    Chen, Weiqian
    Ji, Jiansong
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [28] Dual-energy CT with virtual monoenergetic images to improve the visualization of pancreatic supplying arteries: the normal anatomy and variations
    Liang, Hong-wei
    Zhou, Yang
    Zhang, Zhi-wei
    Yan, Gao-wu
    Du, Si-lin
    Zhang, Xiao-hui
    Li, Xin-you
    Lv, Fa-jin
    Zheng, Qiao
    Li, Yong-mei
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [29] Metal artifact reduction in cervix brachytherapy with titanium applicators using dual-energy CT through virtual monoenergetic images and an iterative algorithm: A phantom study
    Kanani, Abolfazl
    Yazdi, Mehran
    Owrangi, Amir M.
    Karbasi, Sareh
    Mosleh-Shirazi, Mohammad Amin
    BRACHYTHERAPY, 2022, 21 (06) : 933 - 942
  • [30] Quality evaluation of monoenergetic images generated by dual-energy computed tomography for radiotherapy: A phantom study
    Pawalowski, Bartosz
    Szweda, Hubert
    Dudkowiak, Alina
    Piotrowski, Tomasz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 63 : 48 - 55