Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms

被引:5
|
作者
Greffier, Joel [1 ]
Van Ngoc Ty, Claire [2 ]
Fitton, Isabelle [2 ]
Frandon, Julien [1 ]
Beregi, Jean-Paul [1 ]
Dabli, Djamel [1 ]
机构
[1] Montpellier Univ, Nimes Univ Hosp, Dept Med Imaging, IMAGINE UR UM 103, F-30029 Nimes, France
[2] Univ Paris, Hop Europeen Georges Pompidou, AP HP, Dept Radiol, F-75015 Paris, France
关键词
dual-energy; multidetector computed tomography; task-based image quality assessment; split-filter; RECONSTRUCTION;
D O I
10.3390/diagnostics13193039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare the quality of low-energy virtual monoenergetic images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the phantom diameter. Three sections of the Mercury Phantom 4.0 were scanned on two generations of split-filter CTs (SFCT-1st and SFCT-2nd) and on one Dual-source CT (DSCT). The noise power spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were assessed on VMIs from 40 to 70 keV. The highest noise magnitude values were found with SFCT-1st and noise magnitude was higher with DSCT than with SFCT-2nd for 26 cm (10.2% +/- 1.3%) and 31 cm (7.0% +/- 2.5%), and the opposite for 36 cm (-4.2% +/- 2.5%). The highest average NPS spatial frequencies and TTF values at 50% (f50) values were found with DSCT. For all energy levels, the f50 values were higher with SFCT-2nd than SFCT-1st for 26 cm (3.2% +/- 0.4%) and the opposite for 31 cm (-6.9% +/- 0.5%) and 36 cm (-5.6% +/- 0.7%). The lowest d' values were found with SFCT-1st. For all energy levels, the d' values were lower with DSCT than with SFCT-2nd for 26 cm (-6.2% +/- 0.7%), similar for 31 cm (-0.3% +/- 1.9%) and higher for 36 cm (5.4% +/- 2.7%). In conclusion, compared to SFCT-1st, SFCT-2nd exhibited a lower noise magnitude and higher detectability values. Compared with DSCT, SFCT-2nd had a lower noise magnitude and higher detectability for the 26 cm, but the opposite was true for the 36 cm.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Virtual Monoenergetic Images of Dual-Energy CT-Impact on Repeatability, Reproducibility, and Classification in Radiomics
    Euler, Andre
    Laqua, Fabian Christopher
    Cester, Davide
    Lohaus, Niklas
    Sartoretti, Thomas
    dos Santos, Daniel Pinto
    Alkadhi, Hatem
    Baessler, Bettina
    CANCERS, 2021, 13 (18)
  • [2] Phantom-based optimization of virtual monoenergetic image reconstruction in dual-energy CT
    Richter, Anne
    Razinskas, Gary
    Weick, Stefan
    Lutyj, Paul
    Kraft, Johannes
    Wittig-Sauerwein, Andrea
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3848 - S3849
  • [3] Comparison of the spectral performance between two dual-source CT systems on low-energy virtual monoenergetic images: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [4] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [5] Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (09) : 311 - 318
  • [6] Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT
    Albrecht, Moritz H.
    Vogl, Thomas J.
    Martin, Simon S.
    Nance, John W.
    Duguay, Taylor M.
    Wichmann, Julian L.
    De Cecco, Carlo N.
    Varga-Szemes, Akos
    van Assen, Marly
    Tesche, Christian
    Schoepf, U. Joseph
    RADIOLOGY, 2019, 293 (02) : 260 - 271
  • [7] Improved Detection of Endoleaks in Virtual Monoenergetic Images in Dual-Energy CT Angiography Following EVAR
    Kazimierczak, Wojciech
    Kazimierczak, Natalia
    Lemanowicz, Adam
    Nowak, Ewa
    Migdalski, Arkadiusz
    Jawien, Arkadiusz
    Jankowski, Tomasz
    Serafin, Zbigniew
    ACADEMIC RADIOLOGY, 2023, 30 (12) : 2813 - 2824
  • [8] Evaluation of Dual-Energy CT Reconstructed Virtual Monoenergetic Images for Radiation Therapy Treatment Planning
    Broekhoven, B.
    Godwin, W.
    McDonald, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E534 - E534
  • [9] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Francesco Marcello Arico’
    Renato Trimarchi
    Antonio Portaluri
    Claudia Barilla’
    Nicola Migliaccio
    Giuseppe Mauro Bucolo
    Giuseppe Cicero
    Carmelo Sofia
    Christian Booz
    Thomas J. Vogl
    Maria Adele Marino
    Velio Ascenti
    Tommaso D’Angelo
    Silvio Mazziotti
    Giorgio Ascenti
    La radiologia medica, 2023, 128 : 891 - 899
  • [10] Virtual monoenergetic dual-layer dual-energy CT images in colorectal cancer: CT diagnosis could be improved?
    Arico, Francesco Marcello
    Trimarchi, Renato
    Portaluri, Antonio
    Barilla, Claudia
    Migliaccio, Nicola
    Bucolo, Giuseppe Mauro
    Cicero, Giuseppe
    Sofia, Carmelo
    Booz, Christian
    Vogl, Thomas J. J.
    Marino, Maria Adele
    Ascenti, Velio
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Ascenti, Giorgio
    RADIOLOGIA MEDICA, 2023, 128 (08): : 891 - 899