Basal osteotomy of the first metacarpal using patient-specific guides and instrumentation: biomechanical and 3D CT-based analysis

被引:2
|
作者
Nuesch, Clea [1 ]
Schweizer, Andreas [1 ]
Weber, Andreas [1 ]
Reissner, Lisa [1 ]
机构
[1] Balgrist Univ, Hosp Zurich, Div Hand Surg, Forch str 340, CH-8008 Zurich, Switzerland
关键词
Trapeziometacarpal osteoarthritis; Extension osteotomy; Three-dimensional patient-specific planning and instrumentation; Peak load zone; Joint; Articular surface; THUMB CARPOMETACARPAL JOINT; TRAPEZIOMETACARPAL OSTEOARTHRITIS; ARTICULAR-CARTILAGE; EXTENSION OSTEOTOMY; RECONSTRUCTION; ARTHRITIS; OUTCOMES;
D O I
10.1007/s00402-023-05122-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe aim of this study was to investigate the radiological outcomes of proximal closing metacarpal extension osteotomies using patient-specific guides and instruments (PSI) in early-stage trapeziometacarpal osteoarthritis to gain further insight into the joint loading surface and the benefits of the procedure.MethodsIn a prospective observational study, nine patients were included between 11/2020 and 12/2021, undergoing a total of ten proximal metacarpal extension osteotomies for basal thumb osteoarthritis. Computer-assisted surgical planning was performed using computed tomography (CT) and three-dimensional (3D) segmentation, allowing the fabrication of 3D-printed PSIs for surgical treatment. Inclusion criteria were a 1-year follow-up by CT to assess postoperative correction of the positional shift of the first metacarpal (MC1) and the location of peak loads compared with the preoperative situation.ResultsRadiographic analysis of the peak loading zone revealed a mean displacement on the articular surface of the trapezius of 0.4 mm +/- 1.4 mm to radial and 0.1 mm +/- 1.2 mm to palmar, and on the articular surface of the MC1 of 0.4 mm +/- 1.4 mm to radial and 0.1 mm +/- 1.2 mm to dorsal.ConclusionThere were trends indicating that a flatter pressure distribution and a dorsal shift of the peak loading zone may contribute to an improvement in subjective pain and patient satisfaction associated with this surgical procedure. The non-significant radiological results and the minor dorsal-radial shifts in our small study group limit a firm conclusion.Level of evidenceIII.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 50 条
  • [31] MRI-based or CT-based patient-specific instrumentation in Total knee Arthroplasty: How do the two systems compare?
    Dong-Geun Kang
    Kang-Il Kim
    Jung-Kwon Bae
    Arthroplasty, 2
  • [32] MRI-based or CT-based patient-specific instrumentation in Total knee Arthroplasty: How do the two systems compare?
    Kang, Dong-Geun
    Kim, Kang-Il
    Bae, Jung-Kwon
    ARTHROPLASTY, 2020, 2 (01)
  • [33] Corrective osteotomy in symptomatic clavicular malunion using computer-assisted 3-D planning and patient-specific surgical guides
    Grewal, Simran
    Dobbe, Johannes G. G.
    Kloen, Peter
    JOURNAL OF ORTHOPAEDICS, 2018, 15 (02) : 438 - 441
  • [34] 3D-printed saw guides for lower arm osteotomy, a comparison between a synthetic CT and CT-based workflow
    Willemsen, Koen
    Ketel, Mirte H. M.
    Zijlstra, Frank
    Florkow, Mateusz C.
    Kuiper, Ruurd J. A.
    van der Wal, Bart C. H.
    Weinans, Harrie
    Pouran, Behdad
    Beekman, Freek J.
    Seevinck, Peter R.
    Sakkers, Ralph J. B.
    3D PRINTING IN MEDICINE, 2021, 7 (01)
  • [35] How do spine instrumentation parameters influence the 3D correction of thoracic adolescent idiopathic scoliosis? A patient-specific biomechanical study
    La Barbera, Luigi
    Larson, A. Noelle
    Aubin, Carl-Eric
    CLINICAL BIOMECHANICS, 2021, 84
  • [36] Clinical Study of 3D Imaging and 3D Printing Technique for Patient-Specific Instrumentation in Total Knee Arthroplasty
    Qiu, Bing
    Liu, Fei
    Tang, Bensen
    Deng, Biyong
    Liu, Fang
    Zhu, Weimin
    Zhen, Dong
    Xue, Mingyuan
    Zhang, Mingjiao
    JOURNAL OF KNEE SURGERY, 2017, 30 (08) : 822 - 828
  • [37] 3D-printed saw guides for lower arm osteotomy, a comparison between a synthetic CT and CT-based workflow
    Koen Willemsen
    Mirte H. M. Ketel
    Frank Zijlstra
    Mateusz C. Florkow
    Ruurd J. A. Kuiper
    Bart C. H. van der Wal
    Harrie Weinans
    Behdad Pouran
    Freek J. Beekman
    Peter R. Seevinck
    Ralph J. B. Sakkers
    3D Printing in Medicine, 7
  • [38] 3D planning and patient specific instrumentation for intraarticular corrective osteotomy of trapeziometacarpal and finger joints
    Kabelitz, Method
    Furrer, Pascal Raffael
    Hodel, Sandro
    Candronica, Sandro
    Schweizer, Andreas
    SWISS MEDICAL WEEKLY, 2021, 151 : 13S - 13S
  • [39] 3D - Printed Patient Specific Instrumentation in Corrective Osteotomy of the Femur and Pelvis: A Review of the Literature
    Njalalle Baraza
    Chris Chapman
    Sima Zakani
    Kishore Mulpuri
    3D Printing in Medicine, 6
  • [40] How do spine instrumentation parameters influence the 3D correction of thoracic adolescent idiopathic scoliosis? A patient-specific biomechanical study
    La Barbera, Luigi
    Larson, A. Noelle
    Aubin, Carl-Eric
    Clinical Biomechanics, 2021, 84