Basal osteotomy of the first metacarpal using patient-specific guides and instrumentation: biomechanical and 3D CT-based analysis

被引:2
|
作者
Nuesch, Clea [1 ]
Schweizer, Andreas [1 ]
Weber, Andreas [1 ]
Reissner, Lisa [1 ]
机构
[1] Balgrist Univ, Hosp Zurich, Div Hand Surg, Forch str 340, CH-8008 Zurich, Switzerland
关键词
Trapeziometacarpal osteoarthritis; Extension osteotomy; Three-dimensional patient-specific planning and instrumentation; Peak load zone; Joint; Articular surface; THUMB CARPOMETACARPAL JOINT; TRAPEZIOMETACARPAL OSTEOARTHRITIS; ARTICULAR-CARTILAGE; EXTENSION OSTEOTOMY; RECONSTRUCTION; ARTHRITIS; OUTCOMES;
D O I
10.1007/s00402-023-05122-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe aim of this study was to investigate the radiological outcomes of proximal closing metacarpal extension osteotomies using patient-specific guides and instruments (PSI) in early-stage trapeziometacarpal osteoarthritis to gain further insight into the joint loading surface and the benefits of the procedure.MethodsIn a prospective observational study, nine patients were included between 11/2020 and 12/2021, undergoing a total of ten proximal metacarpal extension osteotomies for basal thumb osteoarthritis. Computer-assisted surgical planning was performed using computed tomography (CT) and three-dimensional (3D) segmentation, allowing the fabrication of 3D-printed PSIs for surgical treatment. Inclusion criteria were a 1-year follow-up by CT to assess postoperative correction of the positional shift of the first metacarpal (MC1) and the location of peak loads compared with the preoperative situation.ResultsRadiographic analysis of the peak loading zone revealed a mean displacement on the articular surface of the trapezius of 0.4 mm +/- 1.4 mm to radial and 0.1 mm +/- 1.2 mm to palmar, and on the articular surface of the MC1 of 0.4 mm +/- 1.4 mm to radial and 0.1 mm +/- 1.2 mm to dorsal.ConclusionThere were trends indicating that a flatter pressure distribution and a dorsal shift of the peak loading zone may contribute to an improvement in subjective pain and patient satisfaction associated with this surgical procedure. The non-significant radiological results and the minor dorsal-radial shifts in our small study group limit a firm conclusion.Level of evidenceIII.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 50 条
  • [21] Accuracy of MRI-basedvs. CT-based patient-specific instrumentation in total knee arthroplasty: A meta-analysis
    An, Vincent V. G.
    Sivakumar, Brahman S.
    Phan, Kevin
    Levy, Yadin David
    Bruce, Warwick J. M.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (01) : 116 - 120
  • [22] Biomechanical Analysis of a Patient-Specific Artificial Hip Joint to Design and Manufacture It by 3D Printing
    Le Thi Bich Nam
    Nguyen Lan Phuong
    Nguyen Tien Dat
    Nguyen Thi Kim Cuc
    PROCEEDINGS OF THE 3RD ANNUAL INTERNATIONAL CONFERENCE ON MATERIAL, MACHINES AND METHODS FOR SUSTAINABLE DEVELOPMENT, VOL 2, MMMS 2022, 2024, : 535 - 545
  • [23] Accuracy of CT-based patient-specific guides for total knee arthroplasty in patients with post-traumatic osteoarthritis
    Schotanus M.G.M.
    van Haaren E.H.
    Hendrickx R.P.M.
    Jansen E.J.P.
    Kort N.P.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1313 - 1320
  • [24] Feasibility and 3D Planning of a Novel Patient-Specific Instrumentation Technique in Medial Opening-Wedge High Tibial Osteotomy
    Van Genechten, Wouter
    Van Tilborg, Wouter
    Van den Bempt, Maxim
    Van Haver, Annemieke
    Verdonk, Peter
    JOURNAL OF KNEE SURGERY, 2021, 34 (14) : 1560 - 1569
  • [25] The biomechanical behavior of 3D printed human femoral bones based on generic and patient-specific geometries
    Katharina Nägl
    Andreas Reisinger
    Dieter H. Pahr
    3D Printing in Medicine, 8
  • [26] The biomechanical behavior of 3D printed human femoral bones based on generic and patient-specific geometries
    Nagl, Katharina
    Reisinger, Andreas
    Pahr, Dieter H.
    3D PRINTING IN MEDICINE, 2022, 8 (01)
  • [27] Double level osteotomy of the knee with 3D patient-specific cutting blocks (8251)
    Grabherr, Michael
    Flury, Andreas
    Helmy, Nader
    Antoniadis, Alexander
    SWISS MEDICAL WEEKLY, 2020, : S51 - S51
  • [28] Knee osteotomies: The time has come for 3D planning and patient-specific instrumentation
    Ehlinger, Matthieu
    Favreau, Henri
    Murgier, Jerome
    Ollivier, Matthieu
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (04)
  • [29] Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research
    Nang, Vo Sy Quyen
    Hieu, Pham Trung
    Nam, Vu Tu
    Dung, Tran Trung
    Toan, Duong Dinh
    JOURNAL OF ORTHOPAEDICS, 2025, 62 : 70 - 74
  • [30] Feline Shoulder Arthrodesis Using 3D-printed Patient-specific Guides
    Motta, Claudio
    Condon, Anna Maria
    Owen, Mark Andrew
    Craig, Andrew
    Ridge, Patrick Alan
    Perez, Maria Carolina Perez
    Oxley, William Henry George
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2025,