Clinical application of breathing-adapted 4D CT: image quality comparison to conventional 4D CT

被引:7
|
作者
Werner, Rene [1 ]
Szkitsak, Juliane [2 ,3 ]
Madesta, Frederic [1 ]
Buettgen, Laura [1 ]
Wimmert, Lukas [1 ]
Sentker, Thilo [1 ]
Fietkau, Rainer [2 ,3 ]
Haderlein, Marlen [2 ,3 ]
Bert, Christoph [2 ,3 ]
Gauer, Tobias [1 ]
Hofmann, Christian [4 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, D-20246 Hamburg, Germany
[2] Univ Klinikum Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg, D-91054 Erlangen, Germany
[4] Siemens Healthcare GmbH, D-91301 Forchheim, Germany
关键词
4D radiotherapy; 4D CT; Image artifacts; Image quality; LUNG; ARTIFACTS; GUIDANCE; STRATEGY;
D O I
10.1007/s00066-023-02062-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: 4D CT imaging is an integral part of 4D radiotherapy workflows. However, 4D CT data often contain motion artifacts that mitigate treatment planning. Recently, breathing-adapted 4D CT (i4DCT) was introduced into clinical practice, promising artifact reduction in in-silico and phantom studies. Here, we present an image quality comparison study, pooling clinical patient data from two centers: a new i4DCT and a conventional spiral 4D CT patient cohort.Methods: The i4DCT cohort comprises 129 and the conventional spiral 4D CT cohort 417 4D CT data sets of lung and liver tumor patients. All data were acquired for treatment planning. The study consists of three parts: illustration of image quality in selected patients of the two cohorts with similar breathing patterns; an image quality expert rater study; and automated analysis of the artifact frequency.Results: Image data of the patients with similar breathing patterns underline artifact reduction by i4DCT compared to conventional spiral 4D CT. Based on a subgroup of 50 patients with irregular breathing patterns, the rater study reveals a fraction of almost artifact-free scans of 89% for i4DCT and only 25% for conventional 4D CT; the quantitative analysis indicated a reduction of artifact frequency by 31% for i4DCT.Conclusion: The results demonstrate 4D CT image quality improvement for patients with irregular breathing patterns by breathing-adapted 4D CT in this first corresponding clinical data image quality comparison study.
引用
收藏
页码:686 / 691
页数:6
相关论文
共 50 条
  • [41] Generation of 4D CT Image Data and Analysis of Lung Tumour Mobility during the Breathing Cycle
    Handels, Heinz
    Werner, Rene
    Frenzel, Thorsten
    Saering, Dennis
    Lu, Wei
    Low, Daniel
    Ehrhardt, Jan
    UBIQUITY: TECHNOLOGIES FOR BETTER HEALTH IN AGING SOCIETIES, 2006, 124 : 977 - +
  • [42] Comparison of single and multi-slice CT for 4D CT with respiratory gating
    Pan, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1473 - 1473
  • [43] Abdominal and pancreatic motion correlation using 4D CT, 4D transponders, and a gating belt
    Betancourt, Ricardo
    Zou, Wei
    Plastaras, John P.
    Metz, James M.
    Teo, Boon-Keng
    Kassaee, Alireza
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 13 - 24
  • [44] 4D, or not 4D: that is the question
    Campbell, S
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 19 (01) : 1 - 4
  • [45] A comparison of amplitude- and phase-based 4D CT
    Thorndyke, B
    Schreibmann, E
    Li, T
    Boyer, A
    Xing, L
    MEDICAL PHYSICS, 2005, 32 (06) : 1919 - 1919
  • [46] What is the Effect of the irregular breathing movements in comparison to periodic movements on the volumes contouring in 4D CT?
    Block, A.
    Mewes, A.
    Waletzko, O.
    Noertersheuser, T.
    Rohn, R.
    Mathias, K.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 143 - 143
  • [47] Phase Correlated Image Registration to 4D CT for Liver Stereotactic Radiosurgery with Image Guidance CT
    Juh, R.
    Suh, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [48] Application of motion compensation in 4D CT of oesophageal cancer.
    Green, A.
    Bhatt, L.
    Goldstraw, R.
    Sheikh, H.
    Van Herk, M.
    McWilliam, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S942 - S943
  • [49] A 4D SOFTWARE FOR BREATHING ADAPTED RADIOTHERAPY (BART) OF LUNG CANCER
    Peguret, N.
    Vock, J.
    Fenoglietto, P.
    Azria, D.
    Vinh-Hung, V.
    Miralbell, R.
    JOURNAL OF THORACIC ONCOLOGY, 2010, 5 (05) : S73 - S74
  • [50] A 4D SOFTWARE FOR BREATHING ADAPTED RADIOTHERAPY (RT) OF LUNG CANCER
    Peguret, N.
    Vock, J.
    Fenoglietto, P.
    Azria, D.
    Hung, V. Vinh
    Miralbell, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 (12) : 721 - 721