Clinical application of breathing-adapted 4D CT: image quality comparison to conventional 4D CT

被引:7
|
作者
Werner, Rene [1 ]
Szkitsak, Juliane [2 ,3 ]
Madesta, Frederic [1 ]
Buettgen, Laura [1 ]
Wimmert, Lukas [1 ]
Sentker, Thilo [1 ]
Fietkau, Rainer [2 ,3 ]
Haderlein, Marlen [2 ,3 ]
Bert, Christoph [2 ,3 ]
Gauer, Tobias [1 ]
Hofmann, Christian [4 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, D-20246 Hamburg, Germany
[2] Univ Klinikum Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg, D-91054 Erlangen, Germany
[4] Siemens Healthcare GmbH, D-91301 Forchheim, Germany
关键词
4D radiotherapy; 4D CT; Image artifacts; Image quality; LUNG; ARTIFACTS; GUIDANCE; STRATEGY;
D O I
10.1007/s00066-023-02062-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: 4D CT imaging is an integral part of 4D radiotherapy workflows. However, 4D CT data often contain motion artifacts that mitigate treatment planning. Recently, breathing-adapted 4D CT (i4DCT) was introduced into clinical practice, promising artifact reduction in in-silico and phantom studies. Here, we present an image quality comparison study, pooling clinical patient data from two centers: a new i4DCT and a conventional spiral 4D CT patient cohort.Methods: The i4DCT cohort comprises 129 and the conventional spiral 4D CT cohort 417 4D CT data sets of lung and liver tumor patients. All data were acquired for treatment planning. The study consists of three parts: illustration of image quality in selected patients of the two cohorts with similar breathing patterns; an image quality expert rater study; and automated analysis of the artifact frequency.Results: Image data of the patients with similar breathing patterns underline artifact reduction by i4DCT compared to conventional spiral 4D CT. Based on a subgroup of 50 patients with irregular breathing patterns, the rater study reveals a fraction of almost artifact-free scans of 89% for i4DCT and only 25% for conventional 4D CT; the quantitative analysis indicated a reduction of artifact frequency by 31% for i4DCT.Conclusion: The results demonstrate 4D CT image quality improvement for patients with irregular breathing patterns by breathing-adapted 4D CT in this first corresponding clinical data image quality comparison study.
引用
收藏
页码:686 / 691
页数:6
相关论文
共 50 条
  • [21] Characterization and Identification of Artifacts for Helical 4D CT Image
    Han, D.
    Bayouth, J.
    Bhatia, S.
    Sonka, M.
    Wu, X.
    MEDICAL PHYSICS, 2010, 37 (06) : 3131 - +
  • [22] Projection Image Correction for 4D VMAT-CT
    Saotome, N.
    Kida, S.
    Onoe, T.
    Sasaki, K.
    Imae, T.
    Tanaka, K.
    Sakumi, A.
    Masutani, Y.
    Haga, A.
    Nakagawa, K.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [23] Evaluation of 4D CT to 4D Cone-Beam CT Deformable Image Registration for Lung Cancer Adaptive Radiation Therapy
    Balik, S.
    Hugo, G.
    Weiss, E.
    Jan, N.
    Roman, N.
    Sleeman, W.
    Fatyga, M.
    Christensen, G.
    Murphy, M.
    Lu, J.
    Keall, P.
    Williamson, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3875 - 3875
  • [24] Structure Density Variations between Free Breathing CT and Respiration-Gated 4D CT in Lung SBRT-GATED 4D CT IN LUNG SBRT
    Shang, C.
    Vargas, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [25] Analysis of free breathing motion using artifact reduced 4D CT image data
    Ehrhardt, Jan
    Werner, Rene
    Frenzel, Thorsten
    Lu, Wei
    Low, Daniel
    Handels, Heinz
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [26] Improvement of 4D PET Image via PETs Signal Additivity Derived from 4D CT Scans
    Michalski, D.
    Fallon, K.
    Mulaf, Y. D.
    Heron, D. E.
    Bednarz, G.
    Hull, S. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S645 - S646
  • [27] On-Treatment 4D CT Reconstruction From Planning 4D CT Using Linear Amplitude Scaling
    Park, S.
    Jung, J.
    Kim, J.
    Yeo, I.
    Yi, B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3434 - 3434
  • [28] The effect of mid-scan changes of breathing frequency and amplitude on 4D CT quality
    Noel, C.
    Parikh, P.
    Malinowski, K.
    MEDICAL PHYSICS, 2007, 34 (06) : 2555 - 2555
  • [29] Validation and comparison of registration methods for free-breathing 4D lung-CT
    Vik, Torbjorn
    Kabus, Sven
    von Berg, Jens
    Ens, Konstantin
    Dries, Sebastian
    Klinder, Tobias
    Lorenz, Cristian
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914
  • [30] Feasibility of 4D VMAT-CT
    Zhao, Xiaodong
    Zhang, Rui
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (06)