Osteomyelitis of the Lower Limb: Diagnostic Accuracy of Dual-Energy CT versus MRI

被引:13
|
作者
Foti, Giovanni [1 ]
Longo, Chiara [1 ]
Sorgato, Claudia [2 ]
Oliboni, Eugenio Simone [1 ]
Mazzi, Cristina [3 ]
Motta, Leonardo [4 ]
Bertoli, Giulia [4 ]
Marocco, Stefania [4 ]
机构
[1] IRCCS Sacro Cuore Don Calabria Hosp, Dept Radiol, I-37042 Negrar Di Valpolicella, Verona, Italy
[2] IRCCS Sacro Cuore Don Calabria Hosp, Dept Diabetol, I-37042 Negrar Di Valpolicella, Verona, Italy
[3] IRCCS Osped Sacro Cuore Don Calabria, Clin Res Unit, I-37042 Negrar Di Valpolicella, Verona, Italy
[4] IRCCS Sacro Cuore Don Calabria Hosp, Dept Infect Trop Dis & Microbiol, I-37042 Negrar Di Valpolicella, Verona, Italy
关键词
chronic pain; osteomyelitis; MRI; dual-energy CT; bone marrow edema; BONE-MARROW EDEMA; IMAGING TESTS; FOOT; IDENTIFICATION; PITFALLS; UTILITY;
D O I
10.3390/diagnostics13040703
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: MRI is the preferred imaging technique for the identification of osteomyelitis. The key element for diagnosis is the presence of bone marrow edema (BME). Dual-energy CT (DECT) is an alternative tool which is able to identify BME in the lower limb. Purpose: To compare the diagnostic performance of DECT and MRI for osteomyelitis, using clinical, microbiological, and imaging data as reference standards. Materials and Methods: This prospective single-center study enrolled consecutive patients with suspected bone infections undergoing DECT and MRI imaging from December 2020 to June 2022. Four blinded radiologists with various experience levels (range of 3-21 years) evaluated the imaging findings. Osteomyelitis was diagnosed in the presence of BMEs, abscesses, sinus tracts, bone reabsorption, or gaseous elements. The sensitivity, specificity, and AUC values of each method were determined and compared using a multi-reader multi-case analysis. A p value < 0.05 was considered significant. Results: In total, 44 study participants (mean age 62.5 years +/- 16.5 [SD], 32 men) were evaluated. Osteomyelitis was diagnosed in 32 participants. For the MRI, the mean sensitivity and specificity were 89.1% and 87.5%, while for the DECT they were 89.0% and 72.9%, respectively. The DECT demonstrated a good diagnostic performance (AUC = 0.88), compared with the MRI (AUC = 0.92) (p = 0.12). When considering each imaging finding alone, the best accuracy was achieved by considering BME (AUC for DECT 0.85 versus AUC of MRI of 0.93, with p = 0.07), followed by the presence of bone erosions (AUC 0.77 for DECT and 0.53 for MRI, with p = 0.02). The inter-reader agreement of the DECT (k = 88) was similar to that of the MRI (k = 90). Conclusion: Dual-energy CT demonstrated a good diagnostic performance in detecting osteomyelitis.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Diagnostic Accuracy of Dual-Energy CT for Evaluation of Renal Masses: Systematic Review and Meta-Analysis
    Salameh, Jean-Paul
    McInnes, Matthew D. F.
    McGrath, Trevor A.
    Salameh, Gilles
    Schieda, Nicola
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (04) : W100 - W105
  • [42] Dual-energy CT kidney stone characterization—can diagnostic accuracy be achieved at low radiation dose?
    André Euler
    Sara Wullschleger
    Thomas Sartoretti
    Daniel Müller
    Etienne Xavier Keller
    Dejan Lavrek
    Olivio Donati
    European Radiology, 2023, 33 : 6238 - 6244
  • [43] Dual-Energy CT for Suspected Radiographically Negative Wrist Fractures: A Prospective Diagnostic Test Accuracy Study
    Mueller, Felix C.
    Gosvig, Kasper K.
    Borgesen, Henrik
    Gade, Jesper S.
    Brejnebol, Mathias
    Rodell, Anders
    Nemery, Michel
    Boesen, Mikael
    RADIOLOGY, 2020, 296 (03) : 596 - 602
  • [44] Diagnostic performance of dual-energy CT in nonspecific terminal ileitis
    Xingyuan Xu
    Junting Zhu
    Xia Wang
    Chao Zhu
    Xingwang Wu
    Japanese Journal of Radiology, 2022, 40 : 1069 - 1078
  • [45] Gouty arthritis: the diagnostic and therapeutic impact of dual-energy CT
    Finkenstaedt, Tim
    Manoliou, Andrei
    Toniolo, Martin
    Higashigaito, Kai
    Andreisek, Gustav
    Guggenberger, Roman
    Michel, Beat
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3989 - 3999
  • [46] Gouty arthritis: the diagnostic and therapeutic impact of dual-energy CT
    Tim Finkenstaedt
    Andrei Manoliou
    Martin Toniolo
    Kai Higashigaito
    Gustav Andreisek
    Roman Guggenberger
    Beat Michel
    Hatem Alkadhi
    European Radiology, 2016, 26 : 3989 - 3999
  • [47] Diagnostic Performance of Dual-Energy CT Stress Myocardial Perfusion Imaging: Direct Comparison With Cardiovascular MRI
    Ko, Sung Min
    Song, Meong Gun
    Chee, Hyun Kun
    Hwang, Hweung Kon
    Feuchtner, Gudrun Maria
    Min, James K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) : W605 - W613
  • [48] Diagnostic accuracy of third-generation dual-source dual-energy CT: a prospective trial and protocol for clinical implementation
    Tim Nestler
    Kai Nestler
    Andreas Neisius
    Hendrik Isbarn
    Christopher Netsch
    Stephan Waldeck
    Hans U. Schmelz
    Christian Ruf
    World Journal of Urology, 2019, 37 : 735 - 741
  • [49] Diagnostic accuracy of third-generation dual-source dual-energy CT: a prospective trial and protocol for clinical implementation
    Nestler, Tim
    Nestler, Kai
    Neisius, Andreas
    Isbarn, Hendrik
    Netsch, Christopher
    Waldeck, Stephan
    Schmelz, Hans U.
    Ruf, Christian
    WORLD JOURNAL OF UROLOGY, 2019, 37 (04) : 735 - 741
  • [50] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Giovanni Foti
    Ronaldo Silva
    Niccolò Faccioli
    Alessandro Fighera
    Rossella Menghini
    Arianna Campagnola
    Giovanni Carbognin
    European Radiology, 2021, 31 : 1923 - 1931