Preliminary Experience with a Four-Lead Implantable Pulse Generator for Deep Brain Stimulation

被引:0
|
作者
Rusheen, Aaron E. [1 ,2 ]
Jensen, Michael A. [1 ,2 ]
Gregg, Nicholas M. [3 ]
Kaufmann, Timothy J. [4 ]
Van Gompel, Jamie J. [2 ]
Lee, Kendall H. H. [2 ,5 ]
Klassen, Bryan T. [3 ]
Miller, Kai J. [2 ,5 ]
机构
[1] Mayo Clin, Med Scientist Training Program, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurol Surg, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Neurol, Rochester, MN USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] Mayo Clin, Dept Biomed Engn, Rochester, MN USA
关键词
Implantable pulse generator; Deep brain stimulation; Essential tremor; Parkinson's disease; Epilepsy; Tourette's syndrome; PARKINSONS-DISEASE; SUBTHALAMIC NUCLEUS; DBS; INFECTION; SURGERY; REPLACEMENT; TREMOR;
D O I
10.1159/000530782
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Implantable pulse generators (IPGs) store energy and deliver electrical impulses for deep brain stimulation (DBS) to treat neurological and psychiatric disorders. IPGs have evolved over time to meet the demands of expanding clinical indications and more nuanced therapeutic approaches. Objectives: The aim of this study was to examine the workflow of the first 4-lead IPG for DBS in patients with complex disease. Method: The engineering capabilities, clinical use cases, and surgical technique are described in a cohort of 12 patients with epilepsy, essential tremor, Parkinson's disease, mixed tremor, and Tourette's syndrome with comorbid obsessive-compulsive disorder between July 2021 and July 2022. Results: This system is a rechargeable 32-channel, 4-port system with independent current control that can be connected to 8 contact linear or directionally segmented leads. The system is ideal for patients with mixed disease or those with multiple severe symptoms amenable to >2 lead implantations. A multidisciplinary team including neurologists, radiologists, and neurosurgeons is necessary to safely plan the procedure. There were no serious intraoperative or postoperative adverse events. One patient required revision surgery for bowstringing. Conclusions: This new 4-lead IPG represents an important new tool for DBS surgery with the ability to expand lead implantation paradigms for patients with complex disease.
引用
收藏
页码:254 / 264
页数:11
相关论文
共 50 条
  • [41] Reuse of Internal Pulse Generator in Cases of Infection after Deep Brain Stimulation Surgery
    Gocmen, Selcuk
    Celiker, Ozkan
    Topcu, Abdullah
    Panteli, Aikaterini
    Acar, Goksemin
    Acar, Feridun
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2014, 92 (03) : 140 - 144
  • [42] Thalamic local field potentials recorded using the deep brain stimulation pulse generator
    Buijink, A. W. G.
    Pina-Fuentes, D. A.
    Stam, M. J.
    Bot, M.
    Schuurman, P. R.
    van den Munckhof, P.
    van Rootselaar, A. F.
    de Bie, R. M. A.
    Beudel, M.
    CLINICAL NEUROPHYSIOLOGY PRACTICE, 2022, 7 : 103 - 106
  • [43] Life time of implanted programmable pulse generator for subthalamic deep-brain stimulation
    Anheim, M.
    Fraix, V.
    Chabardes, S.
    Krack, P.
    Benabid, A.
    Pollak, P.
    MOVEMENT DISORDERS, 2006, 21 : S573 - S573
  • [44] Meta-analysis and review of rechargeable implantable pulse generators for spinal cord stimulation and deep brain stimulation
    Ozgan, Denizhan
    Krieg, Sandro M.
    Jakobs, Martin
    BRAIN AND SPINE, 2024, 4
  • [45] Cosmetic considerations for placement of deep brain stimulation pulse generator: the submammary subfascial approach
    Yuen, Jason
    Alameddine, Khaled
    Bah, Eugene S.
    Lee, Kendall H.
    Sharaf, Basel A.
    ACTA NEUROCHIRURGICA, 2023, 165 (03) : 735 - 739
  • [46] Recharge PSYCH A Study on Rechargeable Implantable Pulse Generators in Deep Brain Stimulation for Psychiatric Disorders
    Jakobs, Martin
    Hajiabadi, Mohammad Mehdi
    Agiorre-Padilla, David Hernan
    Giaccobe, Peter
    Unterberg, Andreas W.
    Lozano, Andres M.
    WORLD NEUROSURGERY, 2023, 170 : E331 - E339
  • [47] From Non-rechargeable to Rechargeable Technology: Insights and Management of Pallidal Deep Brain Stimulation in Dystonia after Switching to a Rechargeable Implantable Pulse Generator
    Wolf, M.
    Saryyeva, A.
    Schulte, D.
    Krauss, J.
    Blahak, C.
    MOVEMENT DISORDERS, 2018, 33 : S230 - S230
  • [48] Deep brain stimulation - Timing of generator replacement
    Takanashi, M.
    Sakott, K.
    Nakamura, H.
    MOVEMENT DISORDERS, 2009, 24 : S474 - S474
  • [49] Status dystonicus in tardive dystonia due to depletion of deep brain stimulation's pulse generator
    Miri, S.
    Rohani, M.
    Shahidi, G. A.
    Parvaresh, M.
    MOVEMENT DISORDERS, 2014, 29 : S463 - S463
  • [50] Recharging Difficulty With Pulse Generator After Deep Brain Stimulation: A Case Series of Five Patients
    Li, Hongyang
    Su, Daoqing
    Lai, Yijie
    Xu, Xinmeng
    Zhang, Chencheng
    Sun, Bomin
    Li, Dianyou
    Pan, Yixin
    FRONTIERS IN NEUROSCIENCE, 2021, 15