Preliminary Experience with a Four-Lead Implantable Pulse Generator for Deep Brain Stimulation

被引:0
|
作者
Rusheen, Aaron E. [1 ,2 ]
Jensen, Michael A. [1 ,2 ]
Gregg, Nicholas M. [3 ]
Kaufmann, Timothy J. [4 ]
Van Gompel, Jamie J. [2 ]
Lee, Kendall H. H. [2 ,5 ]
Klassen, Bryan T. [3 ]
Miller, Kai J. [2 ,5 ]
机构
[1] Mayo Clin, Med Scientist Training Program, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Neurol Surg, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Neurol, Rochester, MN USA
[4] Mayo Clin, Dept Radiol, Rochester, MN USA
[5] Mayo Clin, Dept Biomed Engn, Rochester, MN USA
关键词
Implantable pulse generator; Deep brain stimulation; Essential tremor; Parkinson's disease; Epilepsy; Tourette's syndrome; PARKINSONS-DISEASE; SUBTHALAMIC NUCLEUS; DBS; INFECTION; SURGERY; REPLACEMENT; TREMOR;
D O I
10.1159/000530782
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Implantable pulse generators (IPGs) store energy and deliver electrical impulses for deep brain stimulation (DBS) to treat neurological and psychiatric disorders. IPGs have evolved over time to meet the demands of expanding clinical indications and more nuanced therapeutic approaches. Objectives: The aim of this study was to examine the workflow of the first 4-lead IPG for DBS in patients with complex disease. Method: The engineering capabilities, clinical use cases, and surgical technique are described in a cohort of 12 patients with epilepsy, essential tremor, Parkinson's disease, mixed tremor, and Tourette's syndrome with comorbid obsessive-compulsive disorder between July 2021 and July 2022. Results: This system is a rechargeable 32-channel, 4-port system with independent current control that can be connected to 8 contact linear or directionally segmented leads. The system is ideal for patients with mixed disease or those with multiple severe symptoms amenable to >2 lead implantations. A multidisciplinary team including neurologists, radiologists, and neurosurgeons is necessary to safely plan the procedure. There were no serious intraoperative or postoperative adverse events. One patient required revision surgery for bowstringing. Conclusions: This new 4-lead IPG represents an important new tool for DBS surgery with the ability to expand lead implantation paradigms for patients with complex disease.
引用
收藏
页码:254 / 264
页数:11
相关论文
共 50 条
  • [31] Deep Brain Stimulation in Patients with Cardiac Implantable Electronic Devices: Pulse Width Pitfalls
    Ha, Jongmok
    Lee, Dongyeong
    Ahn, Jong Hyeon
    Cho, Jin Whan
    Lee, Jung Il
    Fasano, Alfonso
    Park, Seung Jung
    Youn, Jinyoung
    MOVEMENT DISORDERS CLINICAL PRACTICE, 2024, 11 (07): : 909 - 911
  • [32] Implantable Pulse Generators for Deep Brain Stimulation: Challenges, Complications, and Strategies for Practicality and Longevity
    Sarica, Can
    Iorio-Morin, Christian
    Aguirre-Padilla, David H.
    Najjar, Ahmed
    Paff, Michelle
    Fomenko, Anton
    Yamamoto, Kazuaki
    Zemmar, Ajmal
    Lipsman, Nir
    Ibrahim, George M.
    Hamani, Clement
    Hodaie, Mojgan
    Lozano, Andres M.
    Munhoz, Renato P.
    Fasano, Alfonso
    Kalia, Suneil K.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2021, 15
  • [33] Directional Deep Brain Stimulation Lead Implantation: A Single Center Experience
    Kochanski, R.
    Borghei, A.
    Pal, G.
    Metman, L. Verhagen
    Lynn, F.
    Karl, J.
    Sani, S.
    MOVEMENT DISORDERS, 2019, 34 : S866 - S866
  • [34] Stimulation Pulse Optimization of Deep Brain Stimulation
    Li, Yuqiao
    Wang, Jiang
    Su, Fei
    PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 3600 - 3604
  • [35] Discomfort caused by subcutaneous deep brain pulse-generator and lead-extensions
    Sherif, C.
    Dorfer, C.
    Kalteis, K.
    Thun, C.
    Kaiser, I.
    Gibson, D.
    Alesch, F.
    PARKINSONISM & RELATED DISORDERS, 2007, 13 : S164 - S164
  • [36] Improvement of apraxia of eyelid opening in a patient with Parkinson's disease following the change of the implantable pulse generator for subthalamic nucleus Deep Brain Stimulation
    Kadowaki, T.
    Suzuki, K.
    Hoshiyama, E.
    Uchiyama, T.
    Shingo, T.
    Hirata, K.
    MOVEMENT DISORDERS, 2017, 32
  • [37] Actual performance of the rechargeable Medtronic implantable pulse generator (Activa-RC) for deep brain stimulation (DBS) therapy in dystonia: A case report
    Naushahi, M. J.
    O'Riordan, S.
    Bain, P. G.
    Aziz, T. Z.
    Nandi, D.
    MOVEMENT DISORDERS, 2009, 24 : S488 - S489
  • [38] Pulse generator battery life in deep brain stimulation: out with the old ... in with the less durable?
    de Schlichting, Emmanuel
    Coll, Guillaume
    Zaldivar-Jolissaint, Julien Francisco
    Coste, Jerome
    Marques, Ana Raquel
    Mulliez, Aurelien
    Durif, Franck
    Lemaire, Jean-Jacques
    ACTA NEUROCHIRURGICA, 2019, 161 (10) : 2043 - 2046
  • [39] Cosmetic considerations for placement of deep brain stimulation pulse generator: the submammary subfascial approach
    Jason Yuen
    Khaled Alameddine
    Eugene S. Bah
    Kendall H. Lee
    Basel A. Sharaf
    Acta Neurochirurgica, 2023, 165 : 735 - 739
  • [40] Pulse generator battery life in deep brain stimulation: out with the old… in with the less durable?
    Emmanuel de Schlichting
    Guillaume Coll
    Julien Francisco Zaldivar-Jolissaint
    Jérôme Coste
    Ana Raquel Marques
    Aurélien Mulliez
    Franck Durif
    Jean-Jacques Lemaire
    Acta Neurochirurgica, 2019, 161 : 2043 - 2046