Cooling of a PVT System Using an Underground Heat Exchanger: An Experimental Study

被引:4
|
作者
Majeed, Saif H. [1 ]
Abdul-Zahra, Amar S. [1 ]
Mutasher, Dheya G. [1 ]
Dhahd, Hayder A. [1 ]
Fayad, Mohammed A. [2 ]
Al-Waeli, Ali H. A. [3 ]
Kazem, Hussein A. [4 ]
Chaichan, Miqdam T. [2 ]
Al-Amiery, Ahmed A. [2 ,5 ]
Isahak, Wan Nor Roslam Wan [5 ]
机构
[1] Univ Technol Iraq, Mech Engn Dept, Baghdad 10001, Iraq
[2] Univ Technol Iraq, Energy & Renewable Energies Technol Ctr, Baghdad 10001, Iraq
[3] Amer Univ Iraq, Engn Dept, Sulaimani 46001, Iraq
[4] Sohar Univ, Fac Engn, Sohar 311, Oman
[5] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Chem & Proc Engn, Bangi 43000, Selangor, Malaysia
来源
ACS OMEGA | 2023年 / 8卷 / 33期
关键词
THERMAL PERFORMANCE; GEOTHERMAL-ENERGY; EXERGY ANALYSIS; WATER; PUMP; ENHANCEMENT; NANOFLUIDS; VISCOSITY; PILE; OMAN;
D O I
10.1021/acsomega.2c07900
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the recent decades,the researchers have been focused on theuse of photovoltaic thermal (PVT) systems that provide the best performanceand cooling for the photovoltaic panels. In this study, a PVT systemconsisting of a monocrystalline PV panel and a spiral heat exchangerwas connected to an underground heat exchanger that is buried at adepth of 4 m below the surface of the earth. The procedure of thecurrent study can be considered the first of its kind in the MiddleEast and North Africa region (based on the researchers' knowledge).The study was carried out on agricultural land in Baghdad-Iraq duringmonths of July and August-2022, which are considered the harshestweather conditions for this city. The heat exchanger consists of acopper tube with a length of 21 m and formed in the shape of 3U, andit was buried in the earth and connected with a PVT system. The resultsof the study showed that the site chosen to bury the heat exchanger(4 m deep) has a stable soil temperature at 22.5 & DEG;C. From variousvolumetric flow rates, a flow rate of 0.18 l/s was selected whichis considered the highest flow rate that can show vibration in thePVT system which may harm the system. The practical measurements showedthat the largest difference in the surface temperatures of standalonePV and PVT was around 20 & DEG;C in favor of the latter. The electricalefficiency of the studied PVT system also increased to outperformthe standalone PV system by 127.3%. By comparing the results of thecurrent study with studies of water-cooled PVT systems from the literature,it is clear that the proposed system is feasible and has an acceptableefficiency in such harsh weather conditions tested during the experiment.
引用
收藏
页码:29926 / 29938
页数:13
相关论文
共 50 条
  • [31] Numerical and experimental investigation of multiple heat exchanger modules in cooling and desalination adsorption system using metal organic framework
    Albaik, Ibrahim
    Elsheniti, Mahmoud Badawy
    Al-Dadah, Raya
    Mahmoud, Saad
    Solmaz, Ismail
    ENERGY CONVERSION AND MANAGEMENT, 2022, 251
  • [32] Air cooling by multiport slabs heat exchanger: An experimental approach
    Dasgupta, Engr Sarbadaman
    Askar, Serena
    Ismail, Mohammed
    Fartaj, Amir
    Quaiyum, Md Abdul
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 42 : 46 - 54
  • [33] Experimental and numerical study on cooling performance of a novel earth-to-air heat exchanger system with an inlet plenum chamber
    Yang, Qizhi
    Hu, Zhiru
    Tao, Yao
    Shi, Long
    Tu, Jiyuan
    Chai, Jie
    Wang, Yong
    ENERGY CONVERSION AND MANAGEMENT, 2023, 277
  • [34] Experimental investigation on condensation heat transfer for bundle tube heat exchanger of the PCCS (Passive Containment Cooling System)
    Bae, Byoung-Uhn
    Kim, Seok
    Park, Yu-Sun
    Kang, Kyoung-Ho
    ANNALS OF NUCLEAR ENERGY, 2020, 139
  • [35] Experimental Study of a Tubular Solar Distillation System with Heat Exchanger Using a Parabolic Trough Collector
    Amin, Muhammad
    Umar, Hamdani
    Amir, Fazri
    Ginting, Suma Fachruri
    Sudarsana, Putu Brahmanda
    Septiadi, Wayan Nata
    SUSTAINABILITY, 2022, 14 (21)
  • [36] Experimental and numerical investigation on conjugate performance of fan and heat exchanger of helicopter oil cooling system
    Tang, Jincheng
    Xie, Yongqi
    Wu, Hongwei
    Fang, Zhen
    Yu, Jianzu
    McCluskey, Daniel
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 35
  • [38] An investigation shell and tube heat exchanger for cooling system: A case study of biodiesel plants using lauric acid
    Burmana, Anggara Dwita
    Tambun, Rondang
    Haryanto, Bode
    Sarah, Maya
    Alexander, Vikram
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 58
  • [39] An experimental study of the exergetic performance of an underground air tunnel system for greenhouse cooling
    Ozgener, Leyla
    Ozgener, Onder
    RENEWABLE ENERGY, 2010, 35 (12) : 2804 - 2811
  • [40] Experimental study of the performance of a heat exchanger for a new desalination-cooling technique using ice slurry: A proof of concept
    Yedmel, Maria Aurely
    Nasser, Ahmad
    Hoang, Hong-Minh
    Hunlede, Romuald
    Fournaison, Laurence
    Delahaye, Anthony
    APPLIED THERMAL ENGINEERING, 2024, 250