An experimental study of the exergetic performance of an underground air tunnel system for greenhouse cooling

被引:81
|
作者
Ozgener, Leyla [1 ]
Ozgener, Onder [2 ]
机构
[1] Celal Bayar Univ Muradiye, Fac Engn, Dept Mech Engn, Manisa, Turkey
[2] Ege Univ, Solar Energy Inst, TR-35100 Izmir, Turkey
关键词
Energy; Exergy; Geothermal energy; Underground air tunnel; HEAT-EXCHANGERS; EARTH; MODEL;
D O I
10.1016/j.renene.2010.04.038
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present study highlights the exergetic performance characteristics of an underground air tunnel for greenhouse cooling with a 47 m horizontal, 56 cm nominal diameter U-bend buried galvanized ground heat exchanger. This system was designed and installed in the Solar Energy Institute, Ege University, Izmir, Turkey. Underground air tunnel systems, also known as earth-to-air heat exchangers, are recognized to be outstanding heating. cooling and air heating systems. On the other hand, they have not been used yet in the Turkish market. Greenhouses also have important economical potential in Turkey's agricultural sector. Greenhouses should be cooled during the summer or hot days. In order to establish optimum growth conditions in greenhouses, renewable energy sources should be utilized as much as possible. It is expected that effective use of underground air tunnels with a suitable technology in the modern greenhouses will play a leading role in Turkey in the foreseeable future. The exergy transports between the components and the destructions in each of the components of the system are determined for the average measured parameters obtained from the experimental results. Exergetic efficiencies of the system components are determined in an attempt to assess their individual performances and the potential for improvements is also presented. The daily maximum cooling coefficient of performances (COP) values for the system are also obtained to be 15.8. The total average COP in the experimental period is found to be 10.09. The system COP was calculated based on the amount of cooling produced by the air tunnel and the amount of power required to move the air through the tunnel, while the exergetic efficiency of the air tunnel is found to be in a range among 57.8-63.2%. The overall exergy efficiency value for the system on a product/fuel basis is found to be 60.7%. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2804 / 2811
页数:8
相关论文
共 50 条
  • [1] Exergoeconomic analysis of an underground air tunnel system for greenhouse cooling system
    Ozgener, Onder
    Ozgener, Leyla
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (05): : 995 - 1005
  • [2] Energetic performance test of an underground air tunnel system for greenhouse heating
    Ozgener, Leyla
    Ozgener, Onder
    ENERGY, 2010, 35 (10) : 4079 - 4085
  • [3] Performance of underground rock storage system for heating and cooling of greenhouse
    Lee, SG
    Lee, HW
    Lee, JW
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON DESIGN AND ENVIRONMENTAL CONTROL OF TROPICAL AND SUBTROPICAL GREENHOUSES, 2002, (578): : 359 - 362
  • [4] Exergetic modeling and experimental performance assessment of a novel desiccant cooling system
    Hurdogan, Ertac
    Buyukalaca, Orhan
    Hepbasli, Arif
    Yilmaz, Tuncay
    ENERGY AND BUILDINGS, 2011, 43 (06) : 1489 - 1498
  • [5] Study on a Dynamic Numerical Model of an Underground Air Tunnel System for Cooling Applications-Experimental Validation and Multidimensional Parametrical Analysis
    Tang, Liang
    Liu, Zhengxuan
    Zhou, Yuekuan
    Qin, Di
    Zhang, Guoqiang
    ENERGIES, 2020, 13 (05)
  • [6] Comparative and Exergetic Study of a Gas Turbine System with Inlet Air Cooling
    Direk, Mehmet
    Mert, Mehmet Selcuk
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2018, 25 : 306 - 311
  • [7] Exergetic performance assessment of solar photovoltaic cell (PV) assisted earth to air heat exchanger (EAHE) system for solar greenhouse cooling
    Yildiz, Ahmet
    Ozgener, Onder
    Ozgener, Leyla
    ENERGY AND BUILDINGS, 2011, 43 (11) : 3154 - 3160
  • [8] Exergetic performance evaluation of ejector cooling system
    Tirmizi, Syed A.
    Gandhidasan, P.
    Zubair, Syed M.
    INTERNATIONAL JOURNAL OF EXERGY, 2011, 9 (01) : 80 - 98
  • [9] Experimental study on cooling and dehumidification performance of an ice storage air conditioner used in underground refuge chamber
    Guo, Weishuang
    Zhang, Zujing
    Wu, Hongwei
    Ge, Liang
    Liang, Xing
    Mao, Ruiyong
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 146
  • [10] Experimental Study of the Cooling Performance of Trombe Wall with Geothermal Air Tube System
    Elghamry, Rania
    Hassan, Hamdy
    2019 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY ENGINEERING AND APPLICATION (ICSEEA): INNOVATIVE TECHNOLOGY TOWARD ENERGY RESILIENCE, 2019, : 214 - 219