Cooling of a PVT System Using an Underground Heat Exchanger: An Experimental Study

被引:4
|
作者
Majeed, Saif H. [1 ]
Abdul-Zahra, Amar S. [1 ]
Mutasher, Dheya G. [1 ]
Dhahd, Hayder A. [1 ]
Fayad, Mohammed A. [2 ]
Al-Waeli, Ali H. A. [3 ]
Kazem, Hussein A. [4 ]
Chaichan, Miqdam T. [2 ]
Al-Amiery, Ahmed A. [2 ,5 ]
Isahak, Wan Nor Roslam Wan [5 ]
机构
[1] Univ Technol Iraq, Mech Engn Dept, Baghdad 10001, Iraq
[2] Univ Technol Iraq, Energy & Renewable Energies Technol Ctr, Baghdad 10001, Iraq
[3] Amer Univ Iraq, Engn Dept, Sulaimani 46001, Iraq
[4] Sohar Univ, Fac Engn, Sohar 311, Oman
[5] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Chem & Proc Engn, Bangi 43000, Selangor, Malaysia
来源
ACS OMEGA | 2023年 / 8卷 / 33期
关键词
THERMAL PERFORMANCE; GEOTHERMAL-ENERGY; EXERGY ANALYSIS; WATER; PUMP; ENHANCEMENT; NANOFLUIDS; VISCOSITY; PILE; OMAN;
D O I
10.1021/acsomega.2c07900
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the recent decades,the researchers have been focused on theuse of photovoltaic thermal (PVT) systems that provide the best performanceand cooling for the photovoltaic panels. In this study, a PVT systemconsisting of a monocrystalline PV panel and a spiral heat exchangerwas connected to an underground heat exchanger that is buried at adepth of 4 m below the surface of the earth. The procedure of thecurrent study can be considered the first of its kind in the MiddleEast and North Africa region (based on the researchers' knowledge).The study was carried out on agricultural land in Baghdad-Iraq duringmonths of July and August-2022, which are considered the harshestweather conditions for this city. The heat exchanger consists of acopper tube with a length of 21 m and formed in the shape of 3U, andit was buried in the earth and connected with a PVT system. The resultsof the study showed that the site chosen to bury the heat exchanger(4 m deep) has a stable soil temperature at 22.5 & DEG;C. From variousvolumetric flow rates, a flow rate of 0.18 l/s was selected whichis considered the highest flow rate that can show vibration in thePVT system which may harm the system. The practical measurements showedthat the largest difference in the surface temperatures of standalonePV and PVT was around 20 & DEG;C in favor of the latter. The electricalefficiency of the studied PVT system also increased to outperformthe standalone PV system by 127.3%. By comparing the results of thecurrent study with studies of water-cooled PVT systems from the literature,it is clear that the proposed system is feasible and has an acceptableefficiency in such harsh weather conditions tested during the experiment.
引用
收藏
页码:29926 / 29938
页数:13
相关论文
共 50 条
  • [41] An Experimental Study of the Effect of Converging Channel Heat Exchanger on PV System
    Baloch, Ahmer A. B.
    Bahaidarah, Haitham M. S.
    Gandhidasan, P.
    2015 IEEE 42ND PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2015,
  • [42] Experimental study of heat exchanger basing on absorption cycle for CHP system
    Sun, Jian
    Fu, Lin
    Zhang, Shigang
    APPLIED THERMAL ENGINEERING, 2016, 102 : 1280 - 1286
  • [43] Exergy analysis of a photovoltaic thermal system with earth water heat exchanger cooling system based on experimental data
    Jakhar, Sanjeev
    Soni, Manoj S.
    Gakkhar, Nikhil
    INTERNATIONAL JOURNAL OF EXERGY, 2017, 23 (04) : 367 - 387
  • [44] Experimental study on the heat exchange performance of U-vertical underground heat exchanger by different back filler materials
    Li, Xinguo
    Wang, Hongjun
    Zhao, Jun
    Li, Lixin
    Zhu, Qiang
    Lu, Qiang
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2003, 24 (06): : 810 - 813
  • [45] Experimental Study on the Heat Release Operational Characteristics of a Soil Coupled Ground Heat Exchanger with Assisted Cooling Tower
    Yang, Weibo
    Yang, Binbin
    Xu, Rui
    ENERGIES, 2018, 11 (01):
  • [46] Experimental and Simulant Study on Vertical U-Tube Underground Heat Exchanger in Ground-Source Heat Pump
    Gao, Zhen
    Ma, Jinwei
    Yu, Xiaochun
    Zhang, Yu
    Hu, Ning
    Wang, Yanping
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 53 : 636 - 641
  • [47] Field study of an underground counterflow heat exchanger for ventilation air
    Nilsson, L
    Kangro, A
    SWEDISH JOURNAL OF AGRICULTURAL RESEARCH, 1998, 28 (04): : 207 - 213
  • [48] A parametric study of the heat exchanger copper coils used in an indirect evaporative cooling system
    Fatahian, Esmaeel
    Salarian, Hesamoddin
    Fatahian, Hossein
    SN APPLIED SCIENCES, 2020, 2 (01):
  • [49] Experimental investigation of 2 K JT (Joule-Thomson) cooling system using "distributed JT effect heat exchanger"
    Kim, Kyoung Joong
    Jin, Lingxue
    Jeong, Sangkwon
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [50] Experimental and theoretical study of waste heat recovery from a refrigeration system using a finned helical coil heat exchanger
    Roomi, Bahaulddin K.
    Theeb, Maathe A.
    HEAT TRANSFER, 2020, 49 (06) : 3560 - 3574