Comparison between Novel Anatomical Locking Guide Plate and Conventional Locking Plate for Acetabular Fractures: A Finite Element Analysis

被引:0
|
作者
Liu, Xiao [1 ,2 ]
Gao, Jianpeng [1 ,2 ]
Wu, Xiaoyong [1 ,2 ]
Deng, Junhao [1 ,2 ]
Li, Zijian [1 ,2 ]
Li, Ran [1 ,2 ]
Zhang, Licheng [1 ,2 ]
Liu, Jianheng [1 ,2 ]
Li, Ming [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Orthopaed, 28 Fuxin Rd, Beijing 100853, Peoples R China
[2] Natl Clin Res Ctr Orthoped Sports Med & Rehabil, 28 Fuxin Rd, Beijing 100853, Peoples R China
来源
LIFE-BASEL | 2023年 / 13卷 / 11期
关键词
acetabulum; internal fixators; fractures; finite element analysis; ANTERIOR COLUMN; SCREW FIXATION; TRANSVERSE; CLASSIFICATION; VALIDATION; MANAGEMENT; REDUCTION; EFFICACY; PELVIS;
D O I
10.3390/life13112108
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The treatment of complex acetabular fractures remains a complicated clinical challenge. Our self-designed novel anatomical locking guide plate (NALGP) has previously shown promising potential in T-shaped acetabular fractures (TAF), but a direct comparison with conventional fixations is yet to be made. The TAF model was established based on a volunteer's computer tomography data and then fixed with double column locking plates (DLP), a posterior column locking plate with anterior column screws (LPACS), and our NALGP. Forces of 200 N, 400 N, and 600 N were then loaded on the model vertically downward, respectively. The stress distribution and peaks and maximum displacements at three sites were assessed. We found that the stress area of all three plates was mainly concentrated around the fracture line, while only the matching screws of the NALGP showed no obvious stress concentration points. In addition, the NALGP and DLP showed significantly less fracture fragment displacement than the LPACS at the three main fracture sites. The NALGP was found to have less displacement than DLP at the posterior column and ischiopubic branch sites, especially under the higher loading forces of 400 N and 600 N. The fixation stability of the NALGP for TAF was similar to that of DLP but better than that of LPACS. Moreover, the NALGP and its matching screws have a more reasonable stress distribution under different loads of force and the same strength as the LPACS.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Finite Element Analysis of a Novel Anatomical Locking Guide Plate for Anterior Column and Posterior Hemi-Transverse Acetabular Fractures
    Junhao Deng
    Ming Li
    Jiantao Li
    Zhirui Li
    Fanqi Meng
    Yanmei Zhou
    Peifu Tang
    Yanpeng Zhao
    Licheng Zhang
    Journal of Medical and Biological Engineering, 2021, 41 : 895 - 903
  • [2] Finite Element Analysis of a Novel Anatomical Locking Guide Plate for Anterior Column and Posterior Hemi-Transverse Acetabular Fractures
    Deng, Junhao
    Li, Ming
    Li, Jiantao
    Li, Zhirui
    Meng, Fanqi
    Zhou, Yanmei
    Tang, Peifu
    Zhao, Yanpeng
    Zhang, Licheng
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (6) : 895 - 903
  • [3] A Novel Anatomical Locking Guide Plate for Treating Acetabular Transverse Posterior Wall Fracture: A Finite Element Analysis Study
    Li, Ming
    Deng, Junhao
    Li, Jiantao
    Li, Zhirui
    Zhang, Hao
    Zhao, Yanpeng
    Zhang, Licheng
    Tang, Peifu
    ORTHOPAEDIC SURGERY, 2022, 14 (10) : 2648 - 2656
  • [4] Comparative study of anatomical locking plate and reconstruction plate in treating acetabular fractures
    Zhijiang Li
    Jiantao Li
    Zhirui Li
    Shaobo Nie
    Hao Zhang
    Ming Li
    Jianheng Liu
    Zhongyang Liu
    Gaoxiang Xu
    Licheng Zhang
    Peifu Tang
    International Orthopaedics, 2021, 45 : 2727 - 2734
  • [5] Comparative study of anatomical locking plate and reconstruction plate in treating acetabular fractures
    Li, Zhijiang
    Li, Jiantao
    Li, Zhirui
    Nie, Shaobo
    Zhang, Hao
    Li, Ming
    Liu, Jianheng
    Liu, Zhongyang
    Xu, Gaoxiang
    Zhang, Licheng
    Tang, Peifu
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (10) : 2727 - 2734
  • [6] Finite element analysis of a novel anatomical locking plate for scapular neck fracture
    Xiang, Feifan
    Xiao, Yukun
    Wei, Daiqing
    Tan, Xiaoqi
    He, Siyuan
    Luo, Liang
    Yang, Yunkang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [7] Finite element analysis of a novel anatomical locking plate for scapular neck fracture
    Feifan Xiang
    Yukun Xiao
    Daiqing Wei
    Xiaoqi Tan
    Siyuan He
    Liang Luo
    Yunkang Yang
    Journal of Orthopaedic Surgery and Research, 18
  • [8] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Blazevic, Dejan
    Kodvanj, Janos
    Adamovic, Petra
    Vidovic, Dinko
    Trobonjaca, Zlatko
    Sabalic, Srecko
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [9] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Dejan Blažević
    Janoš Kodvanj
    Petra Adamović
    Dinko Vidović
    Zlatko Trobonjača
    Srećko Sabalić
    Journal of Orthopaedic Surgery and Research, 17
  • [10] Locking Plate Fixation for Canine Acetabular Fractures
    Piana, Francesco
    Solano, Miguel
    Kalff, Stephen
    Yeadon, Russell
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (04) : 294 - 300