Long-term field calibration of low-cost metal oxide VOC sensor: Meteorological and interference gas effects

被引:10
|
作者
Hong, Gung-Hwa [1 ]
Le, Thi-Cuc [1 ]
Lin, Guan-Yu [2 ]
Cheng, Hung-Wen [1 ]
Yu, Jhih-Yuan [3 ]
Dejchanchaiwong, Racha [4 ,5 ]
Tekasakul, Perapong [4 ,6 ]
Tsai, Chuen-Jinn [1 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Inst Environm Engn, Hsinchu, Taiwan
[2] Tunghai Univ, Dept Environm Sci & Engn, Taichung, Taiwan
[3] Environm Protect Adm, Execut Yuan, Dept Environm Monitoring & Informat Management, Taipei, Taiwan
[4] Prince Songkla Univ, Fac Engn, Air Pollut & Hlth Effect Res Ctr, Hat Yai 90110, Thailand
[5] Prince Songkla Univ, Fac Engn, Dept Chem Engn, Hat Yai 90110, Thailand
[6] Prince Songkla Univ, Fac Engn, Dept Mech Engn, Hat Yai 90110, Thailand
关键词
MOS VOC sensor; Field test; MLR model; Air quality; Meteorological; Interference gas; VOLATILE ORGANIC-COMPOUNDS; SNO2; IMPROVEMENT;
D O I
10.1016/j.atmosenv.2023.119955
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to evaluate the performance of the Sensirion SGP30 MOS (metal oxide semiconductor) VOC sensors (SMVSs) for a long sampling period (10-12 months) at different ambient air monitoring stations (AQMSs). In the field tests, temperature (T), relative humidity (RH), carbon monoxide (CO) concentration, and non-methane hydrocarbons (NMHC) concentrations were found to be the crucial parameters influencing the sensor readings. A multiple linear regression (MLR) calibration model using hourly T, RH, CO, and VOC values as parameters was developed at Zhongming (ZM) station and validated at Hsinchu (HC) and Tainan (TN) stations. After calibration, the SMVS performance was improved significantly with the decrease of mean normalized bias (MNBs) and mean normalized errors (MNEs) of hourly-average data from +228 to 473% to & PLUSMN;25.9% and 231-473%-47.2%, respectively based on the reference NMHC values in the AQMSs. For ambient NMHC con-centrations higher than 100 ppbv, the MLR-calibrated results were further improved with MNBs (MNEs) less than & PLUSMN;20% (28.3%). The correlation between calibrated sensor data and reference data was enhanced significantly with the R2 values increasing from 0.27 to 0.50 to 0.65-0.78 at three stations. Therefore, these well-calibrated sensors can become viable tools for many purposes including hotspot identification and characterization, and personal exposure study (MNE<30%).
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Enhancing performance evaluation of low-cost inclinometers for the long-term monitoring of buildings
    Lozano, F.
    Emadi, S.
    Komarizadehasl, S.
    Gonzalez-Arteaga, J.
    Xia, Y.
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [42] Low-cost calcium fluorometry for long-term nanoparticle studies in living cells
    Beck, Connor L.
    Hickman, Clark J.
    Kunze, Anja
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [43] System to generate stable long-term VOC gas mixtures of concentrations in the ppb range for test and calibration purposes
    Richter, M.
    Jann, O.
    Horn, W.
    Pyza, L.
    Wilke, O.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2013, 73 (03): : 103 - 106
  • [44] Long-term evaluation of a low-cost air sensor network for monitoring indoor and outdoor air quality at the community scale
    Connolly, Rachel E.
    Yu, Qiao
    Wang, Zemin
    Chen, Yu-Han
    Liu, Jonathan Z.
    Collier-Oxandale, Ashley
    Papapostolou, Vasileios
    Polidori, Andrea
    Zhu, Yifang
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 807
  • [45] A low-cost in-situ CO2 sensor based on a membrane and NDIR for long-term measurement in seawater
    Meng Li
    Baolu Du
    Jinjia Guo
    Zhihao Zhang
    Zeyu Lu
    Rong’er Zheng
    Journal of Oceanology and Limnology, 2022, 40 : 986 - 998
  • [46] A low-cost in-situ CO2 sensor based on a membrane and NDIR for long-term measurement in seawater
    Li, Meng
    Du, Baolu
    Guo, Jinjia
    Zhang, Zhihao
    Lu, Zeyu
    Zheng, Rong'er
    JOURNAL OF OCEANOLOGY AND LIMNOLOGY, 2022, 40 (03) : 986 - 998
  • [47] Field evaluation of a low-uptake VOC passive sampler suitable for long-term deployments
    Healy, Robert M.
    Pautler, Brent G.
    Groenevelt, Hester
    McAlary, Todd
    Wang, Jonathan M.
    Sofowote, Uwayemi
    Su, Yushan
    Munoz, Anthony
    Todd, Aaron
    ATMOSPHERIC POLLUTION RESEARCH, 2021, 12 (09)
  • [48] Predicting Low-Cost Gas Sensor Readings From Transients Using Long Short-Term Memory Neural Networks
    Culic Gambiroza, Jelena
    Mastelic, Toni
    Kovacevic, Tonko
    Cagalj, Mario
    IEEE INTERNET OF THINGS JOURNAL, 2020, 7 (09): : 8451 - 8461
  • [49] Low-cost Long-term Passive Treatment of Metal-Bearing and ARD Water using Iron Rich Material
    Brown, Adrian
    RELIABLE MINE WATER TECHNOLOGY: PROCEEDINGS OF THE INTERNATIONAL MINE WATER ASSOCIATION ANNUAL CONFERENCE 2013, VOLS I & II, 2013, : 525 - 531
  • [50] A low-cost wireless sensor network for long term monitoring of energy performance and sustainability of buildings
    Telicko, Jevgenijs
    Jakovics, Andris
    Drirkis, Ivars
    4TH CENTRAL EUROPEAN SYMPOSIUM ON BUILDING PHYSICS (CESBP 2019), 2019, 282