Field evaluation of a low-uptake VOC passive sampler suitable for long-term deployments

被引:5
|
作者
Healy, Robert M. [1 ]
Pautler, Brent G. [2 ]
Groenevelt, Hester [3 ]
McAlary, Todd [3 ]
Wang, Jonathan M. [1 ]
Sofowote, Uwayemi [1 ]
Su, Yushan [1 ]
Munoz, Anthony [1 ]
Todd, Aaron [1 ]
机构
[1] Ontario Minist Environm Conservat & Pk, Environm Monitoring & Reporting Branch, Toronto, ON, Canada
[2] SiREM, Guelph, ON, Canada
[3] Geosyntec Consultants, Guelph, ON, Canada
关键词
VOCs; Benzene; Low-uptake; Passive sampling; VOLATILE ORGANIC-COMPOUNDS; SOURCE APPORTIONMENT; SPATIAL-ANALYSIS; INDUSTRIAL-AREA; HEALTH-RISK; BENZENE; AIR; TOLUENE; ETHYLBENZENE; EXPOSURE;
D O I
10.1016/j.apr.2021.101152
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Passive samplers have proven to be effective for continuous monitoring of volatile organic compounds (VOCs) in ambient air in remote, urban and industrial environments. Thermal desorption tubes fitted with endcaps that facilitate passive uptake through diffusion are now routinely used for monitoring fugitive benzene emissions from refineries and petrochemical facilities across North America (EPA Method 325A/B). However, deployment periods of 14 days are typically employed to minimize the risk of poor retention, requiring 26 deployments per year to return an annual average concentration for comparison with chronic exposure health-based standards. Here, we explore extending the deployment duration of these passive samplers to one, two and three months by limiting VOC uptake rates using an alternative diffusive endcap featuring a smaller cross-sectional area. Field testing was performed beside a major highway during two separate three-month campaigns. Uptake rates for benzene, toluene, ethylbenzene and xylenes (BTEX) were observed to remain linear for deployments of up to three months when using the low-uptake endcaps. Application of the low-uptake endcaps and the uptake rates determined here will enable annual average concentrations of BTEX to be calculated using only four tube deployments per year. The cost savings associated with this decreased deployment frequency will facilitate increased spatial resolution during future exposure assessment studies. The stability of selected air toxics within the tubes was also assessed and the results suggest that while aromatic VOCs are stable for storage times of at least 70 days, chloroform and trichloroethylene begin to degrade within two weeks of sampling.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] THE USE OF A PASSIVE SAMPLER FOR THE SIMULTANEOUS DETERMINATION OF LONG-TERM VENTILATION RATES AND VOC CONCENTRATIONS
    MAILAHN, W
    SEIFERT, B
    ULLRICH, D
    MORISKE, HJ
    ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) : 537 - 544
  • [2] Field validation of an active sampling cartridge as a passive sampler for long-term carbonyl monitoring
    Shinohara, N
    Kumagai, K
    Yamamoto, N
    Yanagisawa, Y
    Fujii, M
    Yamasaki, A
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (04): : 419 - 424
  • [3] A novel passive sampler for long-term monitoring of isocyanates in air
    Bekki, Kanae
    Uchiyama, Shigehisa
    Kaihara, Noriko
    Inaba, Yohei
    Ushiyama, Akira
    ATMOSPHERIC ENVIRONMENT, 2024, 338
  • [4] A low-tech, low-cost passive sampler for the long-term monitoring of phosphate loads in rivers and streams
    Mueller, Beat
    Stierli, Ruth
    Gaechter, Rene
    JOURNAL OF ENVIRONMENTAL MONITORING, 2008, 10 (07): : 817 - 820
  • [5] Development of a passive sampler for long-term measurements of formaldehyde and total oxidants in air
    Bertoni, G
    Ciuchini, C
    Di Palo, V
    Possanzini, M
    CHROMATOGRAPHIA, 2005, 61 (7-8) : 385 - 389
  • [6] Development of a Passive Sampler for Long-Term Measurements of Formaldehyde and Total Oxidants in Air
    G. Bertoni
    C. Ciuchini
    V. Di. Palo
    M. Possanzini
    Chromatographia, 2005, 61 : 385 - 389
  • [7] DESIGN AND EVALUATION OF A LONG-TERM SOIL GAS FLUX SAMPLER
    BATTERMAN, SA
    MCQUOWN, BC
    MURTHY, PN
    MCFARLAND, AR
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1992, 26 (04) : 709 - 714
  • [8] Field testing a low-cost passive aerosol sampler for long-term measurement of ambient PM2.5 concentrations and particle composition
    Castillo, Maria D.
    Wagner, Jeff
    Casuccio, Gary S.
    West, Roger R.
    Freedman, Frank R.
    Eisl, Holger M.
    Wang, Zhong-Min
    Yip, Jackson P.
    Kinney, Patrick L.
    ATMOSPHERIC ENVIRONMENT, 2019, 216
  • [9] The internal consistency of the ‘analyst’ diffusive sampler—A long-term field test
    G. Bertoni
    R. Tappa
    I. Allegrini
    Chromatographia, 2001, 54 : 653 - 657
  • [10] Characterizing the Aging of Alphasense NO2 Sensors in Long-Term Field Deployments
    Li, Jiayu
    Hauryliuk, Aliaksei
    Malings, Carl
    Eilenberg, S. Rose
    Subramanian, R.
    Presto, Albert A.
    ACS SENSORS, 2021, 6 (08) : 2952 - 2959