Field evaluation of a low-uptake VOC passive sampler suitable for long-term deployments

被引:5
|
作者
Healy, Robert M. [1 ]
Pautler, Brent G. [2 ]
Groenevelt, Hester [3 ]
McAlary, Todd [3 ]
Wang, Jonathan M. [1 ]
Sofowote, Uwayemi [1 ]
Su, Yushan [1 ]
Munoz, Anthony [1 ]
Todd, Aaron [1 ]
机构
[1] Ontario Minist Environm Conservat & Pk, Environm Monitoring & Reporting Branch, Toronto, ON, Canada
[2] SiREM, Guelph, ON, Canada
[3] Geosyntec Consultants, Guelph, ON, Canada
关键词
VOCs; Benzene; Low-uptake; Passive sampling; VOLATILE ORGANIC-COMPOUNDS; SOURCE APPORTIONMENT; SPATIAL-ANALYSIS; INDUSTRIAL-AREA; HEALTH-RISK; BENZENE; AIR; TOLUENE; ETHYLBENZENE; EXPOSURE;
D O I
10.1016/j.apr.2021.101152
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Passive samplers have proven to be effective for continuous monitoring of volatile organic compounds (VOCs) in ambient air in remote, urban and industrial environments. Thermal desorption tubes fitted with endcaps that facilitate passive uptake through diffusion are now routinely used for monitoring fugitive benzene emissions from refineries and petrochemical facilities across North America (EPA Method 325A/B). However, deployment periods of 14 days are typically employed to minimize the risk of poor retention, requiring 26 deployments per year to return an annual average concentration for comparison with chronic exposure health-based standards. Here, we explore extending the deployment duration of these passive samplers to one, two and three months by limiting VOC uptake rates using an alternative diffusive endcap featuring a smaller cross-sectional area. Field testing was performed beside a major highway during two separate three-month campaigns. Uptake rates for benzene, toluene, ethylbenzene and xylenes (BTEX) were observed to remain linear for deployments of up to three months when using the low-uptake endcaps. Application of the low-uptake endcaps and the uptake rates determined here will enable annual average concentrations of BTEX to be calculated using only four tube deployments per year. The cost savings associated with this decreased deployment frequency will facilitate increased spatial resolution during future exposure assessment studies. The stability of selected air toxics within the tubes was also assessed and the results suggest that while aromatic VOCs are stable for storage times of at least 70 days, chloroform and trichloroethylene begin to degrade within two weeks of sampling.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Long-Term Evaluation of Low-Dose Betamethasone for Ataxia Telangiectasia
    Hasegawa, Setsuko
    Kumada, Satoko
    Tanuma, Naoyuki
    Tsuji-Hosokawa, Atsumi
    Kashimada, Ayako
    Mizuno, Tomoko
    Moriyama, Kengo
    Sugawara, Yuji
    Shirai, Ikuko
    Miyata, Yohane
    Nishida, Hiroya
    Mashimo, Hideaki
    Hasegawa, Takeshi
    Hosokawa, Takatoshi
    Hisakawa, Hiroaki
    Uematsu, Mitsugu
    Fujine, Akio
    Miyata, Rie
    Sakuma, Hiroshi
    Kashimada, Kenichi
    Imai, Kohsuke
    Morio, Tomohiro
    Hayashi, Masaharu
    Mizutani, Shuki
    Takagi, Masatoshi
    PEDIATRIC NEUROLOGY, 2019, 100 : 60 - 66
  • [42] Long-Term Evaluation of Progression in Low-Pressure Glaucoma Patients
    Williams, A. L.
    Chilinska, A.
    Spaeth, G. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [43] Passive air sampler as a tool for long-term air pollution monitoring:: Part 2.: Air genotoxic potency screening assessment
    Cupr, Pavel
    Klanova, Jana
    Bartos, Tomas
    Flegrova, Zuzana
    Kohoutek, Jiri
    Holoubek, Ivan
    ENVIRONMENTAL POLLUTION, 2006, 144 (02) : 406 - 413
  • [44] Passive air sampler as a tool for long-term air pollution monitoring:: Part 1.: Performance assessment for seasonal and spatial variations
    Klanova, Jana
    Kohoutek, Jiri
    Hamplova, Lenka
    Urbanova, Petra
    Holoubek, Ivan
    ENVIRONMENTAL POLLUTION, 2006, 144 (02) : 393 - 405
  • [45] Treatment of osteoporosis by long-term magnetic field with extremely low frequency in rats
    Akpolat, Veysi
    Celik, Mustafa Salih
    Celik, Yusuf
    Akdeniz, Nurten
    Ozerdem, Mehmet Sirac
    GYNECOLOGICAL ENDOCRINOLOGY, 2009, 25 (08) : 524 - 529
  • [46] Phosphorus content in soil, uptake by plants and balance in three European long-term field experiments
    Blake, L
    Mercik, S
    Koerschens, M
    Moskal, S
    Poulton, PR
    Goulding, KWT
    Weigel, A
    Powlson, DS
    NUTRIENT CYCLING IN AGROECOSYSTEMS, 2000, 56 (03) : 263 - 275
  • [47] Phosphorus content in soil, uptake by plants and balance in three European long-term field experiments
    L. Blake
    S. Mercik
    M. Koerschens
    S. Moskal
    P.R. Poulton
    K.W.T. Goulding
    A. Weigel
    D.S. Powlson
    Nutrient Cycling in Agroecosystems, 2000, 56 : 263 - 275
  • [48] A novel low sampling rate and cost-efficient active sampler for medium/long-term monitoring of gaseous pollutants
    Wang, Zhiyuan
    Yu, Tao
    Ye, Jin
    Tian, Lei
    Lin, Bencheng
    Leng, Wenjun
    Liu, Cong
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 461
  • [49] MEASUREMENTS OF DETERMINISTIC PROPAGATION MODELS THROUGH FIELD ASSESSMENTS FOR LONG-TERM EVALUATION
    Waheed, Zain
    Kamboh, Usman Rauf
    Shehzad, Mehboob Nazim
    Taqdees, Muhammad Danish
    Usman, Muhammad
    Fatima, Aroosa
    4TH INTERNATIONAL CONFERENCE ON INNOVATIVE COMPUTING (IC)2, 2021, : 619 - 624
  • [50] Evaluation of long-term carbon sequestration of biochar in soil with biogeochemical field model
    Yin, Jianxiang
    Zhao, Ling
    Xu, Xiaoyun
    Li, Deping
    Qiu, Hao
    Cao, Xinde
    Science of the Total Environment, 2022, 822