Long-term field calibration of low-cost metal oxide VOC sensor: Meteorological and interference gas effects

被引:10
|
作者
Hong, Gung-Hwa [1 ]
Le, Thi-Cuc [1 ]
Lin, Guan-Yu [2 ]
Cheng, Hung-Wen [1 ]
Yu, Jhih-Yuan [3 ]
Dejchanchaiwong, Racha [4 ,5 ]
Tekasakul, Perapong [4 ,6 ]
Tsai, Chuen-Jinn [1 ]
机构
[1] Natl Yang Ming Chiao Tung Univ, Inst Environm Engn, Hsinchu, Taiwan
[2] Tunghai Univ, Dept Environm Sci & Engn, Taichung, Taiwan
[3] Environm Protect Adm, Execut Yuan, Dept Environm Monitoring & Informat Management, Taipei, Taiwan
[4] Prince Songkla Univ, Fac Engn, Air Pollut & Hlth Effect Res Ctr, Hat Yai 90110, Thailand
[5] Prince Songkla Univ, Fac Engn, Dept Chem Engn, Hat Yai 90110, Thailand
[6] Prince Songkla Univ, Fac Engn, Dept Mech Engn, Hat Yai 90110, Thailand
关键词
MOS VOC sensor; Field test; MLR model; Air quality; Meteorological; Interference gas; VOLATILE ORGANIC-COMPOUNDS; SNO2; IMPROVEMENT;
D O I
10.1016/j.atmosenv.2023.119955
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to evaluate the performance of the Sensirion SGP30 MOS (metal oxide semiconductor) VOC sensors (SMVSs) for a long sampling period (10-12 months) at different ambient air monitoring stations (AQMSs). In the field tests, temperature (T), relative humidity (RH), carbon monoxide (CO) concentration, and non-methane hydrocarbons (NMHC) concentrations were found to be the crucial parameters influencing the sensor readings. A multiple linear regression (MLR) calibration model using hourly T, RH, CO, and VOC values as parameters was developed at Zhongming (ZM) station and validated at Hsinchu (HC) and Tainan (TN) stations. After calibration, the SMVS performance was improved significantly with the decrease of mean normalized bias (MNBs) and mean normalized errors (MNEs) of hourly-average data from +228 to 473% to & PLUSMN;25.9% and 231-473%-47.2%, respectively based on the reference NMHC values in the AQMSs. For ambient NMHC con-centrations higher than 100 ppbv, the MLR-calibrated results were further improved with MNBs (MNEs) less than & PLUSMN;20% (28.3%). The correlation between calibrated sensor data and reference data was enhanced significantly with the R2 values increasing from 0.27 to 0.50 to 0.65-0.78 at three stations. Therefore, these well-calibrated sensors can become viable tools for many purposes including hotspot identification and characterization, and personal exposure study (MNE<30%).
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Long-term field comparison of multiple low-cost particulate matter sensors in an outdoor urban environment
    Bulot, Florentin M. J.
    Johnston, Steven J.
    Basford, Philip J.
    Easton, Natasha H. C.
    Apetroaie-Cristea, Mihaela
    Foster, Gavin L.
    Morris, Andrew K. R.
    Cox, Simon J.
    Loxham, Matthew
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [32] Long-term field comparison of multiple low-cost particulate matter sensors in an outdoor urban environment
    Florentin M. J. Bulot
    Steven J. Johnston
    Philip J. Basford
    Natasha H. C. Easton
    Mihaela Apetroaie-Cristea
    Gavin L. Foster
    Andrew K. R. Morris
    Simon J. Cox
    Matthew Loxham
    Scientific Reports, 9
  • [33] RB5 Low-Cost Explorer: Implementing Autonomous Long-Term Exploration on Low-Cost Robotic Hardware
    Seewald, Adam
    Chancan, Marvin
    McCann, Connor M.
    Noh, Seonghoon
    Fallahi, Omeed
    Castillo, Hector
    Abraham, Ian
    Dollar, Aaron M.
    2024 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, ICRA 2024, 2024, : 5977 - 5983
  • [34] Two step calibration method for ozone low-cost sensor: Field experiences with the UrbanSense DCUs
    Sa, J. P.
    Chojer, H.
    Branco, P. T. B. S.
    Alvim-Ferraz, M. C. M.
    Martins, F. G.
    Sousa, S. I., V
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2023, 328
  • [35] On-field test and data calibration of a low-cost sensor for fine particles exposure assessment
    Jiang, Yixuan
    Zhu, Xinlei
    Chen, Chen
    Ge, Yihui
    Wang, Weidong
    Zhao, Zhuohui
    Cai, Jing
    Kan, Haidong
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2021, 211
  • [36] Sensitive and Low-Power Metal Oxide Gas Sensors with a Low-Cost Microelectromechanical Heater
    Chen, Yulong
    Li, Mingjie
    Yan, Wenjun
    Zhuang, Xin
    Ng, Kar Wei
    Cheng, Xing
    ACS OMEGA, 2021, 6 (02): : 1216 - 1222
  • [37] Performance of Low-Cost Open-Top Chambers to Study Long-Term Effects of Carbon Dioxide and Climate under Field Conditions
    Messerli, Jonathan
    Bertrand, Annick
    Bourassa, Josee
    Belanger, Gilles
    Castonguay, Yves
    Tremblay, Gaetan
    Baron, Vern
    Seguin, Philippe
    AGRONOMY JOURNAL, 2015, 107 (03) : 916 - 920
  • [38] Development of a Low-cost Explosive Vapor Detector Using Metal Oxide Gas Sensors
    Ratchapakorn, Natchanon
    Ariyakul, Yossiri
    2017 21ST INTERNATIONAL COMPUTER SCIENCE AND ENGINEERING CONFERENCE (ICSEC 2017), 2017, : 316 - 319
  • [39] Low-cost calcium fluorometry for long-term nanoparticle studies in living cells
    Connor L. Beck
    Clark J. Hickman
    Anja Kunze
    Scientific Reports, 10
  • [40] Long-Term Performance Assessment of Low-Cost Atmospheric Sensors in the Arctic Environment
    Carotenuto, Federico
    Brilli, Lorenzo
    Gioli, Beniamino
    Gualtieri, Giovanni
    Vagnoli, Carolina
    Mazzola, Mauro
    Viola, Angelo Pietro
    Vitale, Vito
    Severi, Mirko
    Traversi, Rita
    Zaldei, Alessandro
    SENSORS, 2020, 20 (07)