Real-time germanium-doped optical fibers for clinical computed tomography dosimetry

被引:2
|
作者
Sarhan, H. G. [1 ]
Saini, S. M. [1 ]
Bahari, N. M. [1 ,2 ]
Bradley, D. A. [3 ,4 ]
Zubair, H. T. [5 ,6 ]
Basaif, A. [5 ]
Oresegun, A. A. [5 ]
Rashid, H. A. Abdul [5 ]
Noor, N. M. [1 ,2 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Radiol, Med Phys Lab, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia, Hosp Abdul Aziz Shah, Med Phys Unit, Serdang 43400, Selangor, Malaysia
[3] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[4] Sunway Univ, Ctr Appl Phys & Radiat Technol, Petaling Jaya 46150, Malaysia
[5] Multimedia Univ, Fac Engn, Fibre Opt Res Ctr, Cyberjaya 63100, Malaysia
[6] Lumisyns Technol Sdn Bhd, Cyberjaya 63100, Malaysia
关键词
Computed Tomography; Fabricated Ge-doped silica Fiber; LS-2000; Radioluminescence; Real-time optical fiber dosimetry; GE;
D O I
10.1016/j.radphyschem.2023.110972
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accel-erating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1% and 5%, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1%, 0.4% and 1.4%, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5%, 2% and 1.3%, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Photosensitivities in germanium-doped planar waveguides and dye-doped polymer optical fibres
    Chu, PL
    Peng, GD
    PHOTOREFRACTIVE FIBER AND CRYSTAL DEVICES: MATERIALS, OPTICAL PROPERTIES, AND APPLICATIONS IV, 1998, 3470 : 120 - 127
  • [42] THE OPTICAL ANISOTROPY OF A COLOR CENTER SPECIFIC TO GERMANIUM-DOPED SYNTHETIC QUARTZ
    COHEN, AJ
    SMITH, HL
    SPECTROCHIMICA ACTA, 1957, 10 (02): : 220 - 221
  • [43] OPTICAL AND ELECTRICAL-PROPERTIES OF GERMANIUM-DOPED AND THERMALLY ANNEALED SILICON
    BABICH, VM
    VALAKH, MY
    KOVALCHUK, VB
    RUDKO, GY
    SHAKHRAICHUK, NI
    UKRAINSKII FIZICHESKII ZHURNAL, 1990, 35 (10): : 1561 - 1565
  • [44] VISIBLE-REGION OPTICAL-ABSORPTION PROPERTY FOR GERMANIUM-DOPED SILICA OPTICAL FIBERS INDUCED BY UV-LIGHT PROPAGATION
    NOGUCHI, K
    UESUGI, N
    SUZUKI, K
    ELECTRONICS LETTERS, 1986, 22 (10) : 519 - 520
  • [45] Real-time optical biopsy and analysis of breast cancer using clinical optical coherence tomography
    Boppart, S. A.
    Zysk, A. M.
    Nguyen, F. T.
    Chaney, E. J.
    Bellafiore, F. J.
    Kotynek, J. G.
    Johnson, P. A.
    Rowland, K. M.
    JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (18)
  • [46] Real-time Measurements of Nonlinear Instabilities in Optical Fibers
    Ryczkowski, Piotr
    Narhi, Mikko
    Billet, Cyril
    Merolla, Jean-Marc
    Dudley, John M.
    Genty, Goery
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [47] REAL-TIME FOURIER TRANSFORMATION IN DISPERSIVE OPTICAL FIBERS
    JANNSON, T
    OPTICS LETTERS, 1983, 8 (04) : 232 - 234
  • [48] DETERMINATION OF ZERO-MATERIAL-DISPERSION WAVELENGTH IN GERMANIUM-DOPED AND PHOSPHORUS-DOPED SILICA FIBERS
    LIN, C
    COHEN, LG
    FRENCH, WG
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (05) : 633 - 633
  • [49] Real-time computed tomography on the cell broadband engine processor
    Bockenbach, Olivier
    Knaup, Michael
    Kachelriess, Marc
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS VI, 2008, 6812
  • [50] Real-time CartoSound imaging of the esophagus: A comparison to computed tomography
    Wilson, Lauren
    Brooks, Anthony G.
    Lau, Dennis H.
    Dimitri, Hany
    Sharma, Gautam
    Lim, Han S.
    Alasady, Muayad
    Young, Glenn D.
    Sanders, Prashanthan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (02) : 260 - 262