Real-time germanium-doped optical fibers for clinical computed tomography dosimetry

被引:2
|
作者
Sarhan, H. G. [1 ]
Saini, S. M. [1 ]
Bahari, N. M. [1 ,2 ]
Bradley, D. A. [3 ,4 ]
Zubair, H. T. [5 ,6 ]
Basaif, A. [5 ]
Oresegun, A. A. [5 ]
Rashid, H. A. Abdul [5 ]
Noor, N. M. [1 ,2 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Radiol, Med Phys Lab, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia, Hosp Abdul Aziz Shah, Med Phys Unit, Serdang 43400, Selangor, Malaysia
[3] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[4] Sunway Univ, Ctr Appl Phys & Radiat Technol, Petaling Jaya 46150, Malaysia
[5] Multimedia Univ, Fac Engn, Fibre Opt Res Ctr, Cyberjaya 63100, Malaysia
[6] Lumisyns Technol Sdn Bhd, Cyberjaya 63100, Malaysia
关键词
Computed Tomography; Fabricated Ge-doped silica Fiber; LS-2000; Radioluminescence; Real-time optical fiber dosimetry; GE;
D O I
10.1016/j.radphyschem.2023.110972
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accel-erating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1% and 5%, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1%, 0.4% and 1.4%, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5%, 2% and 1.3%, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Real-time diffraction computed tomography data reduction
    Kieffer, J.
    Petitdemange, S.
    Vincent, T.
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 612 - 617
  • [32] Optical poling in germanium-doped microstructured optical fiber for visible supercontinuum generation
    Tombelaine, Vincent
    Buy-Lesvigne, Christelle
    Leproux, Philippe
    Couderc, Vincent
    Melin, Gilles
    OPTICS LETTERS, 2008, 33 (17) : 2011 - 2013
  • [33] Long-Period Gratings in Highly Germanium-Doped, Single-Mode Optical Fibers for Sensing Applications
    Schlangen, Sebastian
    Bremer, Kort
    Zheng, Yulong
    Boehm, Sebastian
    Steinke, Michael
    Wellmann, Felix
    Neumann, Joerg
    Roth, Bernhard
    Overmeyer, Ludger
    SENSORS, 2018, 18 (05)
  • [34] Optimization of microstructured fibers with germanium-doped core for broad normal dispersion range
    Biedrzycki, J.
    Tarnowski, K.
    Urbanczyk, W.
    OPTO-ELECTRONICS REVIEW, 2018, 26 (01) : 57 - 62
  • [35] Abnormal growth mechanism of fiber Bragg gratings in high Germanium-doped fibers
    Lima, MJN
    Nogueira, RN
    Silva, JCC
    Teixeira, ALJ
    André, PS
    da Rocha, JRF
    Kalinowski, HJ
    Pinto, JL
    OPTO-IRELAND 2005: OPTOELECTRONICS, PHOTONIC DEVICES, AND OPTICAL NETWORKS, 2005, 5825 : 310 - 315
  • [36] Clinical implementation of a real-time fiberoptic dosimetry system
    Miller, RW
    Ning, H
    Justus, B
    Huston, A
    Falkenstein, P
    Li, G
    Xie, H
    Coleman, CN
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S494 - S494
  • [37] Real-time and functional optical coherence tomography
    Izatt, JA
    Yazdanfar, S
    Westphal, V
    Radhakrishnan, S
    Rollins, AM
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 110 - 112
  • [38] Instrumentation for real-time dynamic optical tomography
    Schmitz, CH
    Pei, YL
    Graber, HL
    Lasker, JM
    Hielscher, AH
    Barbour, RL
    PHOTON MIGRATION, OPTICAL COHERENCE TOMOGRAPHY, AND MICROSCOPY, 2001, 4431 : 282 - 291
  • [39] Electrical and optical properties of germanium-doped zinc oxide thin films
    Arita, M
    Yamaguchi, M
    Masuda, M
    MATERIALS TRANSACTIONS, 2004, 45 (11) : 3180 - 3183
  • [40] DEFECT CENTERS IN A GERMANIUM-DOPED SILICA-CORE OPTICAL FIBER
    FRIEBELE, EJ
    GRISCOM, DL
    SIGEL, GH
    JOURNAL OF APPLIED PHYSICS, 1974, 45 (08) : 3424 - 3428