Real-time germanium-doped optical fibers for clinical computed tomography dosimetry

被引:2
|
作者
Sarhan, H. G. [1 ]
Saini, S. M. [1 ]
Bahari, N. M. [1 ,2 ]
Bradley, D. A. [3 ,4 ]
Zubair, H. T. [5 ,6 ]
Basaif, A. [5 ]
Oresegun, A. A. [5 ]
Rashid, H. A. Abdul [5 ]
Noor, N. M. [1 ,2 ]
机构
[1] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Radiol, Med Phys Lab, Serdang 43400, Selangor, Malaysia
[2] Univ Putra Malaysia, Hosp Abdul Aziz Shah, Med Phys Unit, Serdang 43400, Selangor, Malaysia
[3] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[4] Sunway Univ, Ctr Appl Phys & Radiat Technol, Petaling Jaya 46150, Malaysia
[5] Multimedia Univ, Fac Engn, Fibre Opt Res Ctr, Cyberjaya 63100, Malaysia
[6] Lumisyns Technol Sdn Bhd, Cyberjaya 63100, Malaysia
关键词
Computed Tomography; Fabricated Ge-doped silica Fiber; LS-2000; Radioluminescence; Real-time optical fiber dosimetry; GE;
D O I
10.1016/j.radphyschem.2023.110972
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In studies focusing on the practice of clinical computed tomography (CT) a particular concern has been that of delivering unnecessary dose to patients and with it the added risk for radiation-induced cancers. For a CT system, present work has investigated the dosimetric characteristics of a Ge-doped optical fiber real-time dosimetry system (model LS-2000, Lumisyns), measuring beam quality, exposure linearity and exposure duration accuracy. For comparison, the study has used a RaySafe X2 test device (Unfors RaySafe) and a Black Piranha (RTI) QA meter. Irradiations were made using a Somatom Definition Flash dual-source 128-slice CT scanner (Siemens Healthcare). The LS-2000, RaySafe X2, and Black Piranha sensors were exposed to beams energized at accel-erating potentials ranging from 80 to 140 kVp, with tube current-time products from 50 to 300 mA, and exposure durations from 750 to 2000 ms. Constant signal responses from the LS-2000 have been obtained, measured in respect of beam quality, exposure linearity, and time accuracy. In respect of accuracy of beam quality, the RaySafe X2 and Black Piranha maximum deviations were 1% and 5%, respectively; the coefficients of linearity of RaySafe, Black Piranha and LS-2000 are 1%, 0.4% and 1.4%, respectively; the maximum deviation for the time accuracy test for the three sensors are 0.5%, 2% and 1.3%, respectively. Evaluation of the LS-2000 real-time dosimetry system with a Ge-doped optical fiber scintillator points to potential for its use in clinical CT dosimetry.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer
    Kaplan, Irving D.
    Meskell, Paul
    Oldenburg, Nicklas E.
    Saltzman, Brian
    Kearney, Gary P.
    Holupka, Edward J.
    BRACHYTHERAPY, 2006, 5 (03) : 147 - 151
  • [22] Real-time optical fiber dosimetry in radiotherapy
    Aznar, M
    Polf, J
    Akselrod, M
    Andersen, C
    Back, S
    Boetter-Jensen, L
    Mattsson, S
    McKeever, S
    Medin, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1371 - 1371
  • [23] Effects of time-temperature profiles on glow curves of germanium-doped optical fibre
    Lam, S. E.
    Alawiah, A.
    Bradley, D. A.
    Noor, N. Mohd
    RADIATION PHYSICS AND CHEMISTRY, 2017, 137 : 56 - 61
  • [24] Real-time dosimetry with rare earth doped silica
    Loi, G.
    D'Agostino, E.
    Veronese, I.
    Chiodini, N.
    Vedda, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S402 - S403
  • [25] Real-time radiation dosimetry using P-doped silica optical fiber
    Zubair, H. T.
    Oresegun, A.
    Rahman, A. K. M. Mizanur
    Ung, N. M.
    Sharif, K. A. Mat
    Zulkifli, M. I.
    Yassin, S. Z. Muhd
    Maah, M. J.
    Yusoff, Z.
    Abdul-Rashid, H. A.
    Bradley, D. A.
    Omar, Nasr Y. M.
    MEASUREMENT, 2019, 146 : 119 - 124
  • [26] UV Bragg Grating Inscription in Germanium-doped Photonic Crystal Fibers
    Geernaert, Thomas
    Becker, Martin
    Mergo, Pawel
    Nasilowski, Tomasz
    Wojcik, Jan
    Urbanczyk, Waclaw
    Rothhardt, Manfred
    Chojetzki, Christoph
    Bartelt, Hartmut
    Berghmans, Francis
    Thienpont, Hugo
    PHOTONIC CRYSTAL FIBERS IV, 2010, 7714
  • [27] A methodology for direct quantification of over-ranging length in helical computed tomography with real-time dosimetry
    Tien, Christopher J.
    Winslow, James F.
    Hintenlang, David E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 350 - 361
  • [28] Comparison of real-time intraoperative ultrasound-based dosimetry with postoperative computed tomography-based dosimetry for prostate brachytherapy
    Nag, Subir
    Shi, Peipei
    Liu, Bingren
    Gupta, Nilendu
    Bahnson, Robert R.
    Wang, Jian Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 311 - 317
  • [29] Optical and magnetooptical study of photorefractive germanium-doped cadmium telluride
    Briat, B
    Shcherbin, K
    Farid, B
    Ramaz, F
    OPTICS COMMUNICATIONS, 1998, 156 (4-6) : 337 - 340
  • [30] OPTICAL STUDIES OF ANISOTROPIC COLOR CENTERS IN GERMANIUM-DOPED QUARTZ
    HALPERIN, A
    RALPH, JE
    JOURNAL OF CHEMICAL PHYSICS, 1963, 39 (01): : 63 - &