On the Possibility of Using Medical Linear Electron Accelerators as a Source of the Reference Pulsed Photon Radiation Field

被引:0
|
作者
Zaharadniuk, A. A. [1 ]
Taraev, A. Y. [1 ]
Lazarenko, S. V. [1 ]
机构
[1] SPE ATOMTEX, Gikalo Str, 5, Minsk 220005, BELARUS
来源
DEVICES AND METHODS OF MEASUREMENTS | 2023年 / 14卷 / 03期
关键词
Monte Carlo modelling; linear electron accelerator; pulsed photon radiation;
D O I
10.21122/2220-9506-2023-14-3-179-190
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Sources of pulsed photon radiation are widely used in science and industry. In this regard, there is a growing demand for dosimetry instruments capable of operating in these pulsed photon radiation fields. Until now there is no comprehensive methodology that describes the characteristics of reference fields of pulsed photon radiation required for calibration and verification of dosimetry equipment. The aim of this paper was to study the possibility of using a medical linear electron accelerator as a generating source of a reference pulsed photon radiation field. The paper investigates main characteristics of photon radiation field (namely, spectrum and average energy) generated by CLINAC in two modes of operation: 6 MV and 18 MV. Additionally it researches the possibility of attenuation of the CLINAC photon radiation intensity by a lead filter. The spectrum and average energy of the CLINAC photon radiation were calculated by means of Monte Carlo simulation in the Fluka program. The validation of the calculation was determined by comparing the attenuation coefficients calculated by the model with ones obtained experimentally by using real CLINACs. Experimentally, the attenuation coefficients were obtained by measuring the air kerma rate generated by the photon radiation fields of Varian VitalBeam and Varian iX CLINACs at a given point of space. Based on the simulation results, the H*(10) ambient dose equivalent ratio generated by CLINACs were calculated. It was found that the lead filter effectively attenuates the CLINAC photon radiation in terms of both air kerma rate and ambient dose equivalent rate to levels suitable for calibration of dosimetry equipment designed to measure pulsed radiation. It is shown that the lead filter significantly affects both the photon spectrum of the CLINAC and its average energy.
引用
收藏
页码:179 / 190
页数:12
相关论文
共 50 条
  • [31] REGULATIONS, STANDARDS AND GUIDELINES FOR USE OF MEDICAL ELECTRON LINEAR ACCELERATORS
    TURNER, AP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1048 - 1048
  • [32] Monte Carlo simulation of the photon beam characteristics from medical linear accelerators
    Kim, H. K.
    Han, S. J.
    Kim, J. L.
    Kim, B. H.
    Chang, S. Y.
    Lee, J. K.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 510 - 513
  • [33] Skyshine photon doses from 6 and 10 MV medical linear accelerators
    de Paiva, Eduardo
    da Rosa, Luiz A. R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 215 - 219
  • [34] LARGE-FIELD SUPERFICIAL ELECTRON THERAPY WITH LINEAR ACCELERATORS
    KARZMARK, CJ
    BRITISH JOURNAL OF RADIOLOGY, 1964, 37 (436): : 302 - 305
  • [35] A comparison of the basic photon and electron dosimetry data for Neptun IOPC linear accelerators
    Shokrani, Parvaneh
    Monadi, Shahram
    NUKLEONIKA, 2008, 53 (04) : 181 - 185
  • [36] ONE POSSIBILITY OF MORE EFFECTIVE UTILIZATION OF BEAMS FROM LINEAR ELECTRON-ACCELERATORS
    LAZAREVA, LE
    JETP LETTERS, 1974, 20 (07) : 221 - 222
  • [37] Additional radiation sources in a treatment and control room of medical linear accelerators
    Konefal, Adam
    Bieniasiewicz, Marcin
    Wendykier, Jacek
    Adamczyk, Sebastian
    Wronska, Aleksandra
    RADIATION PHYSICS AND CHEMISTRY, 2021, 185
  • [38] Small compact pulsed electron source for radiation technologies
    Korenev, S
    BEAMS 2002, 2002, 650 : 219 - 222
  • [39] Self-shielded electron linear accelerators designed for radiation technologies
    Belugin, V. M.
    Rozanov, N. E.
    Pirozhenko, V. M.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2009, 12 (09):
  • [40] Medical Radioisotope Production Using Novel Electron Accelerators
    Kelley, S. W.
    HEALTH PHYSICS, 2023, 125 (01): : 3 - 3