Monte Carlo simulation of the photon beam characteristics from medical linear accelerators

被引:9
|
作者
Kim, H. K. [1 ]
Han, S. J.
Kim, J. L.
Kim, B. H.
Chang, S. Y.
Lee, J. K.
机构
[1] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Med Ctr, Seoul 139706, South Korea
[2] Korea Inst Nucl Safety, Nucl Emergency Preparedness, Taejon, South Korea
[3] Korea Atom Energy Res Inst, Dept Hlth Phys, Taejon, South Korea
[4] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
关键词
MODEL; DISTRIBUTIONS;
D O I
10.1093/rpd/nci636
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The MCNPX code has been employed on a personal computer to calculate the dosimetric characteristics of the photon beams from the 6 MV Siemens MX2 and the 10 MV Varian Clinac 2100C linear accelerators. A model of the treatment head includes the major geometric structure within the beam path. The model was used to calculate the energy spectra of the photon beam, percentage depth dose and the dose profiles. The accuracy of the calculated results is examined by comparing them with the measured dose distributions for the two machines. The computed and measured depth dose curves agree to within 2% for all the depths beyond the build-up region for both treatment machines. The calculations agree to within 2% of the measured profiles within the 100-50% dose level. It has been found that the MCNPX code is an effective tool for simulating the clinical photon beam.
引用
收藏
页码:510 / 513
页数:4
相关论文
共 50 条
  • [1] A detailed Monte Carlo simulation of the source term of neutron contamination from medical linear accelerators
    Chen, C
    Sheu, R
    Yeh, C
    Jiang, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1854 - 1854
  • [2] Modeling Cerenkov Emissions From Medical Linear Accelerators: A Monte Carlo Study
    Shrock, Z.
    Oldham, M.
    Adamson, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3580 - 3580
  • [3] A Monte Carlo investigation of photoneutron shielding for medical linear accelerators
    Biggs, P
    Gierga, D
    MEDICAL PHYSICS, 2003, 30 (06) : 1437 - 1437
  • [4] Monte Carlo Investigation of Photon Beam Characteristics and its Variation with Incident Electron Beam Parameters for Indigenous Medical Linear Accelerator
    Mishra, Subhalaxmi
    Dixit, P. K.
    Selvam, T. Palani
    Yavalkar, Sanket S.
    Deshpande, D. D.
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (01) : 1 - 8
  • [5] Calculating photon beam characteristics with Monte Carlo techniques
    van der Zee, W
    Welleweerd, J
    MEDICAL PHYSICS, 1999, 26 (09) : 1883 - 1892
  • [6] Photon skyshine from medical linear accelerators
    McDermott, Patrick N.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (03): : 108 - 114
  • [7] PHOTON BEAM MATCHING AND THE ACCURACY OF A TPS FOR MEDICAL LINEAR ACCELERATORS
    Sjostrom, D.
    Wiviann, O.
    Bjelkengren, U.
    Behrens, C.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S389 - S389
  • [8] Modeling 6 MeV Electron Beam From Medical Linear Accelerator Using Monte Carlo Simulation
    Dechsupa, P.
    Tannanonta, C.
    Phaisangittisakul, N.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Monte Carlo modelling of electron beams from medical accelerators
    Ma, CM
    Jiang, SB
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12): : R157 - R189
  • [10] Monte Carlo source model for photon beam radiotherapy: photon source characteristics
    Fix, MK
    Keall, PJ
    Dawson, K
    Siebers, JV
    MEDICAL PHYSICS, 2004, 31 (11) : 3106 - 3121