Monte Carlo simulation of the photon beam characteristics from medical linear accelerators

被引:9
|
作者
Kim, H. K. [1 ]
Han, S. J.
Kim, J. L.
Kim, B. H.
Chang, S. Y.
Lee, J. K.
机构
[1] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Med Ctr, Seoul 139706, South Korea
[2] Korea Inst Nucl Safety, Nucl Emergency Preparedness, Taejon, South Korea
[3] Korea Atom Energy Res Inst, Dept Hlth Phys, Taejon, South Korea
[4] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
关键词
MODEL; DISTRIBUTIONS;
D O I
10.1093/rpd/nci636
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The MCNPX code has been employed on a personal computer to calculate the dosimetric characteristics of the photon beams from the 6 MV Siemens MX2 and the 10 MV Varian Clinac 2100C linear accelerators. A model of the treatment head includes the major geometric structure within the beam path. The model was used to calculate the energy spectra of the photon beam, percentage depth dose and the dose profiles. The accuracy of the calculated results is examined by comparing them with the measured dose distributions for the two machines. The computed and measured depth dose curves agree to within 2% for all the depths beyond the build-up region for both treatment machines. The calculations agree to within 2% of the measured profiles within the 100-50% dose level. It has been found that the MCNPX code is an effective tool for simulating the clinical photon beam.
引用
收藏
页码:510 / 513
页数:4
相关论文
共 50 条
  • [31] Monte Carlo source model for megavoltage photon-beam radiotherapy: Photon source characteristics
    Fix, M
    Keall, P
    Libby, B
    Mohan, R
    Siebers, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1904 - 1904
  • [32] Characteristics of induced activity from medical linear accelerators
    Wang, Y
    Evans, M
    Podgorsak, E
    MEDICAL PHYSICS, 2005, 32 (06) : 2020 - 2020
  • [33] Characteristics of induced activity from medical linear accelerators
    Wang, YZ
    Evans, MDC
    Podgorsak, EB
    MEDICAL PHYSICS, 2005, 32 (09) : 2899 - 2910
  • [34] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Asghar Mesbahi
    Farshad Seyed Nejad
    Radiation Medicine, 2008, 26 : 331 - 336
  • [35] Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator
    Mesbahi, Asghar
    Nejad, Farshad Seyed
    RADIATION MEDICINE, 2008, 26 (06): : 331 - 336
  • [36] A review of photon beam skyshine studies from medical megavoltage accelerators
    Molazadeh, Mikaeil
    Ghiasi, Hosein
    APPLIED RADIATION AND ISOTOPES, 2025, 219
  • [37] Monte Carlo simulation of a medical linear accelerator for filtered and FFF systems
    Yazǧan C.
    Eçen Y.C.
    Yazǧan, Çaǧr (cagri.yazgan@gmail.com), 2017, TUBITAK (41): : 498 - 506
  • [38] Monte Carlo Simulation-Based BEAMnrc Code of a 6 MV Photon Beam Produced by a Linear Accelerator (LINAC)
    Sapundani, R.
    Ekawati, R.
    Wibowo, K. M.
    ATOM INDONESIA, 2021, 47 (03) : 199 - 204
  • [39] Monte Carlo simulation of photoneutron dose in radiotherapy with linear accelerators using an anthropomorphic voxel phantom
    Frankl, M.
    Macian, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 749 - 750
  • [40] Monte Carlo simulation for Neptun 10 PC medical linear accelerator and calculations of output factor for electron beam
    Toossi, Mohammad Taghi Bahreyni
    Momennezhad, Mehdi
    Hashemi, Seyed Mohammad
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (02) : 115 - 118